Tomoyuki Goto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tomoyuki Goto has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Hana Mizutani
Department of Cardiology and Nephrology (M.M., K.M., N.F., Y.K., H.M., R.O., K.D.), Mie University Graduate School of Medicine, Tsu, Japan
1 shared publicationHaruka Fu
Cardiovascular Surgery, Japanese Red Cross Kyoto Daini Hospital, Kyoto, Japan
1 shared publication- Kaoru Dohi
Mie University Graduate School of Medicine
1 shared publication - Keishi Moriwaki
Department of Cardiology and Nephrology, Mie University Graduate School of Medicine
1 shared publication Kyoko Imanaka-Yoshida
Department of Pathology and Matrix Biology (K.I.-Y.), Mie University Graduate School of Medicine, Tsu, Japan
1 shared publication- Masafumi Matsumura
Division of Biomedical Engineering, Graduate School of Biomedical Engineering, Osaka Electro-Communication University, Osaka, Japan
1 shared publication
Latest Publications
- 9 October 2025
- Published by SAGE Publications in Perfusion
Impact of changes in cardiopulmonary bypass circuit design on pressure loss, wall shear stress, and venous drainage flow
Introduction: Blood damage during cardiopulmonary bypass can trigger postoperative inflammatory responses and organ injury. Therefore, optimizing the blood circuit design to minimize damage remains essential. However, variations in venous drainage circuit configurations persist across facilities, and standardization remains limited. Methods: Herein, we conducted computational fluid dynamics (CFD) analysis using the finite volume method to investigate the influence of venous drainage circuit shape on pressure loss, wall shear stress (WSS), and venous drainage flow. The circuit inner diameter (8–14 mm) and branching angle (20°–160°) varied, while the head pressure was set at −70 cmH 2 O. Results: The venous drainage flow decreased as the branching angle increased, although not significantly. The pressure loss increased at higher flow rates, with a more pronounced effect when the inner diameter was reduced. Similarly, the WSS increased with both higher flow rates and smaller inner diameters, suggesting an elevated risk of blood damage. Multiple regression analysis identified venous drainage flow and circuit inner diameter as the primary determinants of WSS. Moreover, an inner diameter of 12 mm was determined to be optimal, as it effectively maintained venous drainage, while minimizing pressure loss and reducing the WSS. Conclusions: Appropriate selection of circuit inner diameter is critical for mitigating the risk of blood damage, while ensuring the necessary venous drainage flow (∼7.0 L/min) for cardiopulmonary bypass in adults. These findings may facilitate the standardization and optimization of cardiopulmonary bypass circuit designs, thereby advancing safer cardiopulmonary support technologies.
- 9 October 2025
- Published by SAGE Publications in Perfusion
Impact of changes in cardiopulmonary bypass circuit design on pressure loss, wall shear stress, and venous drainage flow
Introduction: Blood damage during cardiopulmonary bypass can trigger postoperative inflammatory responses and organ injury. Therefore, optimizing the blood circuit design to minimize damage remains essential. However, variations in venous drainage circuit configurations persist across facilities, and standardization remains limited. Methods: Herein, we conducted computational fluid dynamics (CFD) analysis using the finite volume method to investigate the influence of venous drainage circuit shape on pressure loss, wall shear stress (WSS), and venous drainage flow. The circuit inner diameter (8–14 mm) and branching angle (20°–160°) varied, while the head pressure was set at −70 cmH 2 O. Results: The venous drainage flow decreased as the branching angle increased, although not significantly. The pressure loss increased at higher flow rates, with a more pronounced effect when the inner diameter was reduced. Similarly, the WSS increased with both higher flow rates and smaller inner diameters, suggesting an elevated risk of blood damage. Multiple regression analysis identified venous drainage flow and circuit inner diameter as the primary determinants of WSS. Moreover, an inner diameter of 12 mm was determined to be optimal, as it effectively maintained venous drainage, while minimizing pressure loss and reducing the WSS. Conclusions: Appropriate selection of circuit inner diameter is critical for mitigating the risk of blood damage, while ensuring the necessary venous drainage flow (∼7.0 L/min) for cardiopulmonary bypass in adults. These findings may facilitate the standardization and optimization of cardiopulmonary bypass circuit designs, thereby advancing safer cardiopulmonary support technologies.
- 1 December 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 17 (12) , e016905
Vanishing Left Atrial Mass in a Middle-aged Woman: Spontaneous Intramural Left Atrial Hematoma in Isolated Atrial Amyloidosis
- 1 December 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 17 (12) , e016905
Vanishing Left Atrial Mass in a Middle-aged Woman: Spontaneous Intramural Left Atrial Hematoma in Isolated Atrial Amyloidosis
- Open Access
- 21 May 2021
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 16 (1) , 1-4
A life-saving case of cardiopulmonary arrest with cardiac tamponade caused by erosion 6 years after percutaneous atrial septal defect closure: a case report
Background: Cardiac erosion after percutaneous atrial septal defect (ASD) closure is a rare complication that requires immediate life-saving emergency surgery. In this report, we present our successful life-saving strategy for cardiac arrest due to cardiac tamponade caused by erosion 6 years after the percutaneous closure of an ASD. Case presentation: The patient was a 50-year-old man who received treatment using an Amplatzer septal occluder (St. Jude Medical, St. Paul, MN, USA) treatment for ostium secundum atrial septal defect (size: 29.5 × 27.0 mm) at another institution when he was 44 years old. Conclusions: This case report presents a bailout surgical strategy for patients who are hemodynamically unstable with risks of coagulopathy and multiple organ failure. This case shows that cardiac surgeons need to be aware of percutaneous ASD-closure complications and should consider a bailout surgical strategy for patients at risk of multiple organ failure.
- 21 May 2021
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 16 (1) , 1-4
Open AccessA life-saving case of cardiopulmonary arrest with cardiac tamponade caused by erosion 6 years after percutaneous atrial septal defect closure: a case report
Background: Cardiac erosion after percutaneous atrial septal defect (ASD) closure is a rare complication that requires immediate life-saving emergency surgery. In this report, we present our successful life-saving strategy for cardiac arrest due to cardiac tamponade caused by erosion 6 years after the percutaneous closure of an ASD. Case presentation: The patient was a 50-year-old man who received treatment using an Amplatzer septal occluder (St. Jude Medical, St. Paul, MN, USA) treatment for ostium secundum atrial septal defect (size: 29.5 × 27.0 mm) at another institution when he was 44 years old. Conclusions: This case report presents a bailout surgical strategy for patients who are hemodynamically unstable with risks of coagulopathy and multiple organ failure. This case shows that cardiac surgeons need to be aware of percutaneous ASD-closure complications and should consider a bailout surgical strategy for patients at risk of multiple organ failure.