Harold L. Kennedy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Harold L. Kennedy has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Collins Odhiambo
Department of Pediatrics University of Illinois College of Medicine at Peoria Peoria Illinois USA
2 shared publications - James J. Joyce
Jacksonville Pediatric and Adult Congenital Cardiology, Jacksonville, USA
2 shared publications - Soujanya Bogarapu
Department of Pediatrics Cardiology, Division of Pediatrics, University of Illinois College of Medicine at Peoria , 420 NE Glen Oak Avenue, Peoria, IL 61603
2 shared publications - Sunita Juliana Ferns
Division of Pediatric Cardiology, University of Illinois College of Medicine-Peoria, Peoria, USA
2 shared publications - Pavana Sreenivasan
Division of Pediatric Critical Care, University of Illinois College of Medicine-Peoria, Peoria, USA
1 shared publication
Latest Publications
- Open Access
- 10 March 2026
- Published by Springer Nature in Pediatric Cardiology
- p. 1-15
Pediatric Reference Limits for Holter Monitor Heart Rate Variability Parameters: Defined Using Meta-Analysis
Low heart rate variability (HRV) has been associated with increased risk of morbidity and mortality. While HRV measurements from Holter monitoring have been available for over 3 decades, pediatric reference limits have not been adequately defined. We sought to determine these limits using meta-analysis. Multiple databases were searched through 2024 for relevant studies. Data extraction with meta-analysis and estimation of 95% reference ranges were performed. Linear time- and frequency-domain HRV variables were grouped by the following age ranges: infants (birth-11 months), younger children (1–6 years), older children (7–12 years), and adolescents (13–18 years). Forty-nine studies including 2993 participants were analyzed. SDNN (standard deviation of all sinus NN intervals), SDANN (standard deviation of averages of NN intervals in all 5 min segments), SDNNi (mean of standard deviations of NN intervals for all 5 min segments), rMSSD (root mean square of differences between adjacent NN intervals), and pNN50 (percentage of adjacent NN intervals that varied by more than 50ms) all demonstrated a progressive increase in younger children that required subdivision of that reference range. SDNN and SDANN exhibited further milder increases into adolescence, while SDNNi, rMSSD, and pNN50 remained relatively stable after age 4 years. LF (low frequency) and HF (high frequency) parameters increased abruptly from infancy to early childhood with minimal change thereafter. Remarkably, pediatric age-group lower limits for rMSSD, pNN50, and LF/HF were frequently at or near zero, limiting their utility for detecting decreased HRV. Age-stratified Holter monitor reference limits for HRV parameters in infants, children and adolescents are proposed.
- 10 March 2026
- Published by Springer Nature in Pediatric Cardiology
- p. 1-15
Open AccessPediatric Reference Limits for Holter Monitor Heart Rate Variability Parameters: Defined Using Meta-Analysis
Low heart rate variability (HRV) has been associated with increased risk of morbidity and mortality. While HRV measurements from Holter monitoring have been available for over 3 decades, pediatric reference limits have not been adequately defined. We sought to determine these limits using meta-analysis. Multiple databases were searched through 2024 for relevant studies. Data extraction with meta-analysis and estimation of 95% reference ranges were performed. Linear time- and frequency-domain HRV variables were grouped by the following age ranges: infants (birth-11 months), younger children (1–6 years), older children (7–12 years), and adolescents (13–18 years). Forty-nine studies including 2993 participants were analyzed. SDNN (standard deviation of all sinus NN intervals), SDANN (standard deviation of averages of NN intervals in all 5 min segments), SDNNi (mean of standard deviations of NN intervals for all 5 min segments), rMSSD (root mean square of differences between adjacent NN intervals), and pNN50 (percentage of adjacent NN intervals that varied by more than 50ms) all demonstrated a progressive increase in younger children that required subdivision of that reference range. SDNN and SDANN exhibited further milder increases into adolescence, while SDNNi, rMSSD, and pNN50 remained relatively stable after age 4 years. LF (low frequency) and HF (high frequency) parameters increased abruptly from infancy to early childhood with minimal change thereafter. Remarkably, pediatric age-group lower limits for rMSSD, pNN50, and LF/HF were frequently at or near zero, limiting their utility for detecting decreased HRV. Age-stratified Holter monitor reference limits for HRV parameters in infants, children and adolescents are proposed.
- Open Access
- 3 June 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (11) , e039783
Holter Monitor Rhythm Parameters in Healthy Infants, Children, and Adolescents: Defining Reference Limits With Meta‐Analysis
Background: Ambulatory electrocardiography has been in clinical use for 5 decades. However, reference limits for rhythm parameters in healthy infants, children, and adolescents have not been adequately defined. We sought to determine these reference ranges using meta‐analysis of existing published studies of 24‐hour Holter monitoring in healthy pediatric populations. Methods: Multiple literature databases were searched from 1969 to May 2024 for relevant studies. Data extraction and analysis were completed according to the Meta‐Analysis of Observational Studies in Epidemiology guidelines. The prevalence of cardiac ectopy and conduction delays along with mean±SD of heart rates were obtained and grouped by the following age ranges: neonates (birth to 4 weeks), older infants (1–12 months), younger children (1–6 years), older children (7–12 years), and adolescents (13–18 years). Ninety‐five percent reference ranges for all rhythm variables were estimated in each age group. Results: Forty‐five studies including 3886 participants were identified and analyzed. Minimum, average, and maximum heart rates during Holter monitoring decreased with age as expected. Prevalence of transient first‐degree atrioventricular block and Wenckebach second‐degree atrioventricular block increased with age to around 14% in adolescence. Prevalence rates for any premature atrial complexes and premature ventricular complexes were also highest in adolescence at 50% and 29%, respectively. The upper limits for the number of premature atrial complexes per day were 150 in infants and 50 in the older age groups and for premature ventricular complexes were 50 in all age groups. Conclusions: Holter monitor age‐related reference limits for healthy infants, children, and adolescents are proposed.
- 3 June 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (11) , e039783
Open AccessHolter Monitor Rhythm Parameters in Healthy Infants, Children, and Adolescents: Defining Reference Limits With Meta‐Analysis
Background: Ambulatory electrocardiography has been in clinical use for 5 decades. However, reference limits for rhythm parameters in healthy infants, children, and adolescents have not been adequately defined. We sought to determine these reference ranges using meta‐analysis of existing published studies of 24‐hour Holter monitoring in healthy pediatric populations. Methods: Multiple literature databases were searched from 1969 to May 2024 for relevant studies. Data extraction and analysis were completed according to the Meta‐Analysis of Observational Studies in Epidemiology guidelines. The prevalence of cardiac ectopy and conduction delays along with mean±SD of heart rates were obtained and grouped by the following age ranges: neonates (birth to 4 weeks), older infants (1–12 months), younger children (1–6 years), older children (7–12 years), and adolescents (13–18 years). Ninety‐five percent reference ranges for all rhythm variables were estimated in each age group. Results: Forty‐five studies including 3886 participants were identified and analyzed. Minimum, average, and maximum heart rates during Holter monitoring decreased with age as expected. Prevalence of transient first‐degree atrioventricular block and Wenckebach second‐degree atrioventricular block increased with age to around 14% in adolescence. Prevalence rates for any premature atrial complexes and premature ventricular complexes were also highest in adolescence at 50% and 29%, respectively. The upper limits for the number of premature atrial complexes per day were 150 in infants and 50 in the older age groups and for premature ventricular complexes were 50 in all age groups. Conclusions: Holter monitor age‐related reference limits for healthy infants, children, and adolescents are proposed.