Hristo Radev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hristo Radev has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Galidiya Petrova
Department of Electronics, Faculty of Electronics and Automation, Technical University of Sofia, Plovdiv Branch, 25 “Tsanko Dyustabanov” Str., 4000 Plovdiv, Bulgaria
4 shared publications Galidiya Petrova
Technical University of Sofia Plovdiv branch 25 Tsanko Djustabanov Str.,Faculty of Electronics and Automation,Department of Electronics,Plovdiv,Bulgaria,4000
1 shared publicationGrisha Spasov
Technical University of Sofia Plovdiv branch 25 Tsanko Djustabanov Str.,Faculty of Electronics and Automation,Department of Electronics,Plovdiv,Bulgaria,4000
1 shared publication- Mitko Shopov
Department of Computer Systems and Technologies, Faculty of Electronics and Automation, Technical University of Sofia, 4000 Plovdiv, Bulgaria
1 shared publication - Nikolay Kakanakov
Faculty of Electronics and Automation, Plovdiv Branch, Technical University of Sofia, 4000 Plovdiv, Bulgaria
1 shared publication
Latest Publications
- Open Access
- 14 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (20) , 10201
Validation of Commercial Wearables for Driver Monitoring: Assessing Heart Rate Accuracy and Reliability for Early Detection of Sudden Illnesses
Sudden medical illnesses (SMI), including myocardial infarctions and occult arrhythmias, represent a primary etiology of catastrophic motor vehicle collisions. Although consumer wearable technologies provide a non-invasive modality for continuous driver monitoring, their measurement accuracy within dynamic automotive environments requires systematic evaluation. This investigation establishes an empirical validation paradigm for assessing the pulse-rate (PR) accuracy of consumer-grade wrist and finger photoplethysmography (PPG) devices against a reference heart rate (HR) value derived from an electrocardiographic (ECG) signal. To secure an uncompromised physiological reference, an analytical signal-processing pipeline was implemented, incorporating an Adaptive Layer-Dependent Thresholding Function (ALDTF) coupled with Maximal Overlap Discrete Wavelet Transform (MODWT) decomposition to suppress high-frequency motion artifacts and baseline wander (BW) in the ECG signal without inducing morphological distortion. Nineteen real-world driving sessions, totaling over 18 h of continuous physiological telemetry, were evaluated via Lin’s Concordance Correlation Coefficient and Bland–Altman limit-of-agreement statistics. The findings demonstrate a distinct performance bifurcation governed by device form factor and internal data filtering. The evaluated smartwatch exhibited reliable tracking (MAE = 2.73 BPM) and preserved underlying autonomic variability, attaining distributional alignment with the ECG reference in 47% of trials. Conversely, ring-based form factors demonstrated substantial perfusion decoupling induced by isometric manual gripping forces, alongside aggressive proprietary smoothing filters that suppressed micro-fluctuations in heart rate variability (0% distributional alignment). These outcomes indicate that while wrist-worn form factors possess sufficient fidelity for detecting subclinical autonomic shifts, their implementation in automotive safety systems requires access to raw data to circumvent proprietary algorithmic filtering.
- 14 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (20) , 10201
Open AccessValidation of Commercial Wearables for Driver Monitoring: Assessing Heart Rate Accuracy and Reliability for Early Detection of Sudden Illnesses
Sudden medical illnesses (SMI), including myocardial infarctions and occult arrhythmias, represent a primary etiology of catastrophic motor vehicle collisions. Although consumer wearable technologies provide a non-invasive modality for continuous driver monitoring, their measurement accuracy within dynamic automotive environments requires systematic evaluation. This investigation establishes an empirical validation paradigm for assessing the pulse-rate (PR) accuracy of consumer-grade wrist and finger photoplethysmography (PPG) devices against a reference heart rate (HR) value derived from an electrocardiographic (ECG) signal. To secure an uncompromised physiological reference, an analytical signal-processing pipeline was implemented, incorporating an Adaptive Layer-Dependent Thresholding Function (ALDTF) coupled with Maximal Overlap Discrete Wavelet Transform (MODWT) decomposition to suppress high-frequency motion artifacts and baseline wander (BW) in the ECG signal without inducing morphological distortion. Nineteen real-world driving sessions, totaling over 18 h of continuous physiological telemetry, were evaluated via Lin’s Concordance Correlation Coefficient and Bland–Altman limit-of-agreement statistics. The findings demonstrate a distinct performance bifurcation governed by device form factor and internal data filtering. The evaluated smartwatch exhibited reliable tracking (MAE = 2.73 BPM) and preserved underlying autonomic variability, attaining distributional alignment with the ECG reference in 47% of trials. Conversely, ring-based form factors demonstrated substantial perfusion decoupling induced by isometric manual gripping forces, alongside aggressive proprietary smoothing filters that suppressed micro-fluctuations in heart rate variability (0% distributional alignment). These outcomes indicate that while wrist-worn form factors possess sufficient fidelity for detecting subclinical autonomic shifts, their implementation in automotive safety systems requires access to raw data to circumvent proprietary algorithmic filtering.
- Open Access
- 21 July 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 150 (1) , 34
An Experimental Setup for Collecting Physiological Data from Vehicle Drivers
This paper presents an experimental framework for synchronizing multi-modal physiological data in a real-world driving environment. Research-grade sensors (CardioBAN, respiBAN) were integrated with consumer wearables (Huawei Watch D2, Oura, and Xmart smart rings) to monitor driver heart rate (HR) and respiration rate (RR). A custom MATLAB (version R2024a, 24.1.0)-based workflow was developed to align disparate data streams, using a nearest-neighbor principle to ensure temporal accuracy. The setup was validated through 60 min driving sessions, successfully correlating physiological responses with video feeds. Our results demonstrate that, with proper synchronization, consumer wearables can be compared with precise research-grade equipment for continuous driver state monitoring.
- 21 July 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 150 (1) , 34
Open AccessAn Experimental Setup for Collecting Physiological Data from Vehicle Drivers
This paper presents an experimental framework for synchronizing multi-modal physiological data in a real-world driving environment. Research-grade sensors (CardioBAN, respiBAN) were integrated with consumer wearables (Huawei Watch D2, Oura, and Xmart smart rings) to monitor driver heart rate (HR) and respiration rate (RR). A custom MATLAB (version R2024a, 24.1.0)-based workflow was developed to align disparate data streams, using a nearest-neighbor principle to ensure temporal accuracy. The setup was validated through 60 min driving sessions, successfully correlating physiological responses with video feeds. Our results demonstrate that, with proper synchronization, consumer wearables can be compared with precise research-grade equipment for continuous driver state monitoring.
- Open Access
- 11 July 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 100 (1) , 30
Sensors and Sensing Methods for Early Detection of Life-Threatening Sudden Illnesses in Motor Vehicles Drivers
Due to the increasing number of vehicles and the aging population, the vulnerability to sudden medical emergencies among drivers is a growing problem. Events such as heart attack, stroke, and loss of consciousness can occur without warning and endanger everyone on the road. Modern vehicles, equipped with electronic systems, can support real-time driver’s health monitoring through early detection technologies. The existing Driver Monitoring Systems (DMS) in our cars assess behavioral states such as drowsiness and distraction. In the future, DMS will include biometric sensors to monitor vital signs such as heart rate and respiration. By finding predictors of sudden illnesses (SI), such a system will provide valuable time for the driver to react before the strike of a medical event. In this paper, we present our vision for DMS operation with physiological monitoring capabilities. A brief overview of sensor’s types and their locations in the vehicle interior used in the research studies for monitoring the corresponding physiological parameters is presented. A comparative analysis of the advantages and disadvantages of the sensing methods used for physiological monitoring of the driver in real driving scenarios is made.
- 11 July 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 100 (1) , 30
Open AccessSensors and Sensing Methods for Early Detection of Life-Threatening Sudden Illnesses in Motor Vehicles Drivers
Due to the increasing number of vehicles and the aging population, the vulnerability to sudden medical emergencies among drivers is a growing problem. Events such as heart attack, stroke, and loss of consciousness can occur without warning and endanger everyone on the road. Modern vehicles, equipped with electronic systems, can support real-time driver’s health monitoring through early detection technologies. The existing Driver Monitoring Systems (DMS) in our cars assess behavioral states such as drowsiness and distraction. In the future, DMS will include biometric sensors to monitor vital signs such as heart rate and respiration. By finding predictors of sudden illnesses (SI), such a system will provide valuable time for the driver to react before the strike of a medical event. In this paper, we present our vision for DMS operation with physiological monitoring capabilities. A brief overview of sensor’s types and their locations in the vehicle interior used in the research studies for monitoring the corresponding physiological parameters is presented. A comparative analysis of the advantages and disadvantages of the sensing methods used for physiological monitoring of the driver in real driving scenarios is made.
- Open Access
- 7 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (13) , 7609
A Taxonomy of Methods, Techniques and Sensors for Acquisition of Physiological Signals in Driver Monitoring Systems
Driver monitoring systems (DMSs) are increasingly important for road safety, aiming to reduce driver-caused accidents. Traditional DMSs, focusing on behavioral and observable signals, lack the sensitivity to detect changes in the driver’s health status. Monitoring physiological parameters offers the opportunity to objectively assess the driver’s condition in real time and detect early signs of medical emergencies. After a brief overview of the physiological parameters that are critical for assessing the driver’s condition, we examine the different methods and sensors for obtaining the relevant physiological signals with their advantages and limitations. Based on this review, a taxonomy of methods, techniques, and sensors for acquisition of physiological signals in DMSs is proposed. It provides a systematically structured and detailed classification to understand the relationships between physiological parameters and the different methods and sensors for their measurement. This taxonomy can serve as a fundamental framework for researchers and developers to design and implement reliable next-generation DMSs based on physiological signals.
- 7 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (13) , 7609
Open AccessA Taxonomy of Methods, Techniques and Sensors for Acquisition of Physiological Signals in Driver Monitoring Systems
Driver monitoring systems (DMSs) are increasingly important for road safety, aiming to reduce driver-caused accidents. Traditional DMSs, focusing on behavioral and observable signals, lack the sensitivity to detect changes in the driver’s health status. Monitoring physiological parameters offers the opportunity to objectively assess the driver’s condition in real time and detect early signs of medical emergencies. After a brief overview of the physiological parameters that are critical for assessing the driver’s condition, we examine the different methods and sensors for obtaining the relevant physiological signals with their advantages and limitations. Based on this review, a taxonomy of methods, techniques, and sensors for acquisition of physiological signals in DMSs is proposed. It provides a systematically structured and detailed classification to understand the relationships between physiological parameters and the different methods and sensors for their measurement. This taxonomy can serve as a fundamental framework for researchers and developers to design and implement reliable next-generation DMSs based on physiological signals.
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Driver physiological parameters monitoring–initial study in real-road driving
Among the human factors which contribute to road accidents and crashes special attention deserve medical conditions, drowsiness and fatigue. Monitoring the physiological parameters of the vehicle driver in a real-road driving is a very challenging task, as the signals from biomedical sensors are often distorted by noises, motion artefacts and vibrations inside the car. In this paper a system for monitoring a driver’s physiological signals from Electrocardiogram (ECG), Respiratory Rate (RR), Electrodermal Activity (EDA) and Photoplethysmography (PPG) sensors is presented. The signals are collected in real driving scenarios on different road types and various locations of sensing electrodes in order to determine their appropriate placement for obtaining high quality signals. The results show that placing the ECG sensor electrodes below the chest is preferable because the signal is less affected by motion artefacts, vibration and noise. Also, better quality signals are obtained when the belt with an integrated RR sensor is located in close proximity to the level of diaphragm, EDA electrodes are placed on the right hand palm and PPG sensor is attached to the earlobe.
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Driver physiological parameters monitoring–initial study in real-road driving
Among the human factors which contribute to road accidents and crashes special attention deserve medical conditions, drowsiness and fatigue. Monitoring the physiological parameters of the vehicle driver in a real-road driving is a very challenging task, as the signals from biomedical sensors are often distorted by noises, motion artefacts and vibrations inside the car. In this paper a system for monitoring a driver’s physiological signals from Electrocardiogram (ECG), Respiratory Rate (RR), Electrodermal Activity (EDA) and Photoplethysmography (PPG) sensors is presented. The signals are collected in real driving scenarios on different road types and various locations of sensing electrodes in order to determine their appropriate placement for obtaining high quality signals. The results show that placing the ECG sensor electrodes below the chest is preferable because the signal is less affected by motion artefacts, vibration and noise. Also, better quality signals are obtained when the belt with an integrated RR sensor is located in close proximity to the level of diaphragm, EDA electrodes are placed on the right hand palm and PPG sensor is attached to the earlobe.