Runyu Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Runyu Jiang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Andrey Elagin
Enrico Fermi Institute, University of Chicago, Chicago, IL 60637, USA
1 shared publication - James J. Sohn
Department of Radiation and Cellular Oncology University of Chicago Chicago Illinois USA
1 shared publication - Malvern Madondo
Department of Radiation & Cellular Oncology, University of Chicago, Chicago, IL, United States of America
1 shared publication Mohammadamin Moradi
Department of Radiation & Cellular Oncology, University of Chicago, Chicago, IL, United States of America
1 shared publicationTianming Wu
Department of Radiation & Cellular Oncology, University of Chicago, Chicago, IL, United States of America
1 shared publication- Xiaofeng Yang
Emory University
1 shared publication
Latest Publications
- Open Access
- 6 June 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (11) , 115023
Deep learning-based applicator selection between Syed and T&O in high-dose-rate brachytherapy for locally advanced cervical cancer: a retrospective study
Objective. High-dose-rate (HDR) brachytherapy is integral to the standard-of-care for locally advanced cervical cancer (LACC). Currently, selection of brachytherapy applicators relies on physician’s clinical experience, which can lead to variability in treatment quality and outcomes. This study presents a deep learning-based decision-support tool for selecting between interstitial Syed applicators and intracavitary tandem & ovoids applicators. Approach. The network architecture consists of six 3D convolutional-pooling-rectified linear unit blocks, followed by a fully connected block. The input to the network includes three channels: a 3D contour mask of clinical target volume (CTV), organs at risk (OAR), and central tandem, and two 3D distance maps of CTV and OAR voxels relative to the tandem’s central axis. The network outputs a probability score, indicating the suitability of Syed applicators. Binary cross-entropy loss combined with L 1 regularization was used for network training. Main results. A retrospective study was performed on 184 LACC patients with 422 instances of applicator insertion. The data was divided into three sets: Dataset-1 of 163 patients with 372 insertions for training and hyperparameter tuning, Dataset-2 of 17 patients with 36 insertions and Dataset-3 of four complex cases with 14 insertions for testing. Five-fold cross-validation was performed on Dataset-1, during which hyperparameters were heuristically tuned to optimize classification accuracy across the folds. The highest average accuracy was 92.1 ± 3.8%. Using the hyperparameters that resulted in this highest accuracy, the final model was then trained on the full Dataset-1, and evaluated on the other two independent datasets, achieving 96.0% accuracy, 90.9% sensitivity, and 97.4% specificity. Significance. These results demonstrate the potential of our model as a quality assurance tool in LACC HDR brachytherapy, providing feedback on physicians’ applicator choice and supporting continuous improvement in decision-making. Future work will focus on collecting more data for further validation and extending its application for prospective applicator selection.
- 6 June 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (11) , 115023
Open AccessDeep learning-based applicator selection between Syed and T&O in high-dose-rate brachytherapy for locally advanced cervical cancer: a retrospective study
Objective. High-dose-rate (HDR) brachytherapy is integral to the standard-of-care for locally advanced cervical cancer (LACC). Currently, selection of brachytherapy applicators relies on physician’s clinical experience, which can lead to variability in treatment quality and outcomes. This study presents a deep learning-based decision-support tool for selecting between interstitial Syed applicators and intracavitary tandem & ovoids applicators. Approach. The network architecture consists of six 3D convolutional-pooling-rectified linear unit blocks, followed by a fully connected block. The input to the network includes three channels: a 3D contour mask of clinical target volume (CTV), organs at risk (OAR), and central tandem, and two 3D distance maps of CTV and OAR voxels relative to the tandem’s central axis. The network outputs a probability score, indicating the suitability of Syed applicators. Binary cross-entropy loss combined with L 1 regularization was used for network training. Main results. A retrospective study was performed on 184 LACC patients with 422 instances of applicator insertion. The data was divided into three sets: Dataset-1 of 163 patients with 372 insertions for training and hyperparameter tuning, Dataset-2 of 17 patients with 36 insertions and Dataset-3 of four complex cases with 14 insertions for testing. Five-fold cross-validation was performed on Dataset-1, during which hyperparameters were heuristically tuned to optimize classification accuracy across the folds. The highest average accuracy was 92.1 ± 3.8%. Using the hyperparameters that resulted in this highest accuracy, the final model was then trained on the full Dataset-1, and evaluated on the other two independent datasets, achieving 96.0% accuracy, 90.9% sensitivity, and 97.4% specificity. Significance. These results demonstrate the potential of our model as a quality assurance tool in LACC HDR brachytherapy, providing feedback on physicians’ applicator choice and supporting continuous improvement in decision-making. Future work will focus on collecting more data for further validation and extending its application for prospective applicator selection.
- Open Access
Space-Time Discriminant to Separate Double-Beta Decay from $^8$B Solar Neutrinos in Liquid Scintillator
We present a technique for separating double beta-decay from $^8$B solar neutrino interactions in a liquid scintillator detector. The technique uses position and time of photo-electrons (PEs) to separate directional Cherenkov light from isotropic sintillation light in the reconstruction of the kinematics of candidate events. Here we introduce a Cherenkov-scintillation space time boundary defined as the light cone in the 2-dimensional space of the arrival time and the polar angle of each PE with respect to the axis from the center of the detector to the vertex. The PEs located near the boundary correspond to photons that were emitted early and contain a high fraction of directional Cherenkov PEs. We apply weights derived from the distance to the boundary of each individual PE, which are then used in a spherical harmonics analysis that separates the two-track event topology of double-beta decay from the one-track topology of $^8$B events. The Geant-4 simulation assumes a detector of 6.5 m radius filled with $^{130}$Te-loaded liquid scintillator and surrounded by photo-detectors with time and space resolutions of 100 ps and 3 mm respectively. The scintillation properties and photo-detector quantum efficiency are modeled after KamLAND. Assuming a fiducial volume of 3 m radius, a photo-coverage of 65% and vertex resolution of $\sigma_{r_v} = $ 5.2 cm at 2.53 MeV the method of reconstructing event topology predicts factors of 1.3 and 2.3 in background suppression at 90% and 70% signal efficiency respectively. Additionally, the PEs near the Cherenkov-scintillation space-time boundary can be used to reconstruct the directionality of one-electron candidate events, allowing for further $^8$B background suppression due to the correlation between the direction of the scattered electron and the position of the sun. We find polar and azimuthal angular resolutions of 0.46 and 0.84 radians respectively.Open AccessSpace-Time Discriminant to Separate Double-Beta Decay from $^8$B Solar Neutrinos in Liquid Scintillator
We present a technique for separating double beta-decay from $^8$B solar neutrino interactions in a liquid scintillator detector. The technique uses position and time of photo-electrons (PEs) to separate directional Cherenkov light from isotropic sintillation light in the reconstruction of the kinematics of candidate events. Here we introduce a Cherenkov-scintillation space time boundary defined as the light cone in the 2-dimensional space of the arrival time and the polar angle of each PE with respect to the axis from the center of the detector to the vertex. The PEs located near the boundary correspond to photons that were emitted early and contain a high fraction of directional Cherenkov PEs. We apply weights derived from the distance to the boundary of each individual PE, which are then used in a spherical harmonics analysis that separates the two-track event topology of double-beta decay from the one-track topology of $^8$B events. The Geant-4 simulation assumes a detector of 6.5 m radius filled with $^{130}$Te-loaded liquid scintillator and surrounded by photo-detectors with time and space resolutions of 100 ps and 3 mm respectively. The scintillation properties and photo-detector quantum efficiency are modeled after KamLAND. Assuming a fiducial volume of 3 m radius, a photo-coverage of 65% and vertex resolution of $\sigma_{r_v} = $ 5.2 cm at 2.53 MeV the method of reconstructing event topology predicts factors of 1.3 and 2.3 in background suppression at 90% and 70% signal efficiency respectively. Additionally, the PEs near the Cherenkov-scintillation space-time boundary can be used to reconstruct the directionality of one-electron candidate events, allowing for further $^8$B background suppression due to the correlation between the direction of the scattered electron and the position of the sun. We find polar and azimuthal angular resolutions of 0.46 and 0.84 radians respectively.