Mikias Legesse Gebremedhin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mikias Legesse Gebremedhin has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Binbin Du
Department of Cardiology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
3 shared publications Zhao Ruixue
Department of Cardiology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
3 shared publications- Milan Sigdel
Department of Interventional Radiology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
2 shared publications - Yanzhou Zhang
Department of Cardiology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
2 shared publications - Chengzhi Zhang
Department of Interventional Radiology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
1 shared publication - Dechao Jiao
Department of Interventional Radiology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
1 shared publication
Latest Publications
- Open Access
- 9 January 2026
- Published by Wiley in Radiology Research and Practice
- Vol. 2026 (1)
Percutaneous Transhepatic Retrieval of Dysfunctional Plastic Biliary Stents
Purpose: To evaluate the safety and efficacy of percutaneous transhepatic retrieval of dysfunctional plastic biliary stent (PBS). Materials and Methods: In this retrospective, single‐center study, clinical and procedural data of 36 patients who underwent percutaneous transhepatic retrieval of dysfunctional PBS between January 2015 and April 2021 were analyzed. The primary outcomes were technical success, clinical success, complications, procedure time, and radiation exposure. The secondary outcomes were biochemical indicators (total bilirubin [TB], direct bilirubin [DB], glutamic transaminase [ALT], and CA‐19‐9) measured before treatment and two weeks posttreatment. Results: Technical and clinical success were both 100%. Minor complications occurred in 4 cases (11.2%), including 3 hemobilia (Grade 1) and 1 mild cholangitis (Grade 2). The mean procedure time was 39.22 ± 9.34 minutes, with no statistical significance between benign and malignant disease groups ([40.52 ± 9.0] min vs. [38.91 ± 9.5], p = 0.68). The mean radiation exposure was 326.13 ± 206.06 mGy, with no statistical significance between benign and malignant groups ([353.64 ± 258.93] mGy vs. [319.49 ± 196.15] mGy, p > 0.75). Liver functions parameter improved significantly after 2 weeks (TB: [168.31 ± 53.07] vs. [41.70 ± 7.29] μmol/L, DB: [133.51 ± 46.42] vs. [25.39 ± 7.26] μmol/L, ALT: [94.67 ± 38.06] vs. [47.41 ± 13.69] U/L, and CA‐19‐9: [479.11 ± 160.14] vs. [150.72 ± 105.72] U/mL) (all p = 0.01). Conclusion: This study suggests that percutaneous transhepatic retrieval of dysfunctional PBS appears to be a safe and effective alternative when ERCP is not feasible. However, given the retrospective single‐center design, limited sample size, and short follow‐up, larger multicenter studies with longer observation are needed to validate these findings.
- 9 January 2026
- Published by Wiley in Radiology Research and Practice
- Vol. 2026 (1)
Open AccessPercutaneous Transhepatic Retrieval of Dysfunctional Plastic Biliary Stents
Purpose: To evaluate the safety and efficacy of percutaneous transhepatic retrieval of dysfunctional plastic biliary stent (PBS). Materials and Methods: In this retrospective, single‐center study, clinical and procedural data of 36 patients who underwent percutaneous transhepatic retrieval of dysfunctional PBS between January 2015 and April 2021 were analyzed. The primary outcomes were technical success, clinical success, complications, procedure time, and radiation exposure. The secondary outcomes were biochemical indicators (total bilirubin [TB], direct bilirubin [DB], glutamic transaminase [ALT], and CA‐19‐9) measured before treatment and two weeks posttreatment. Results: Technical and clinical success were both 100%. Minor complications occurred in 4 cases (11.2%), including 3 hemobilia (Grade 1) and 1 mild cholangitis (Grade 2). The mean procedure time was 39.22 ± 9.34 minutes, with no statistical significance between benign and malignant disease groups ([40.52 ± 9.0] min vs. [38.91 ± 9.5], p = 0.68). The mean radiation exposure was 326.13 ± 206.06 mGy, with no statistical significance between benign and malignant groups ([353.64 ± 258.93] mGy vs. [319.49 ± 196.15] mGy, p > 0.75). Liver functions parameter improved significantly after 2 weeks (TB: [168.31 ± 53.07] vs. [41.70 ± 7.29] μmol/L, DB: [133.51 ± 46.42] vs. [25.39 ± 7.26] μmol/L, ALT: [94.67 ± 38.06] vs. [47.41 ± 13.69] U/L, and CA‐19‐9: [479.11 ± 160.14] vs. [150.72 ± 105.72] U/mL) (all p = 0.01). Conclusion: This study suggests that percutaneous transhepatic retrieval of dysfunctional PBS appears to be a safe and effective alternative when ERCP is not feasible. However, given the retrospective single‐center design, limited sample size, and short follow‐up, larger multicenter studies with longer observation are needed to validate these findings.
- Open Access
- 30 December 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (12) , e0326548
What role should EBU catheters play in the interventional approach to anomalous right coronary arteries? A case series
Background: Percutaneous coronary intervention (PCI) for anomalous right coronary artery (ARCA) remains technically challenging due to variable ostial anatomy. The Extra Back-Up (EBU) catheter, although designed for left coronary interventions, may offer advantages in ARCA PCI, but its performance across anatomical subtypes is not well defined. Methods: This single-center retrospective case series included 17 patients (2019–2024) with ARCA from the left coronary sinus or with high take-off anatomy, in whom an EBU catheter was used. Fourteen patients underwent PCI, one had fractional flow reserve (FFR)-only assessment, and two underwent diagnostic angiography alone. Anatomical subtypes were: Type A (ostium above left coronary artery [LCA]), Type B (below LCA), Type C (midline), or high take-off (≥10 mm above sinotubular junction). Primary outcomes were procedural success (stable engagement, full device delivery, no catheter exchange) and safety. Results: Procedural success with the EBU catheter was 100% in Type A (2/2) and 83.3% in Type B (5/6) when used as the initial guide. In Type C and high take-off anatomies, success was achieved in one of two cases each. EBU was also employed as a second-choice catheter in five patients(one Type A, three Type B, one high take-off) after failed engagement with standard guides catheters. No catheter-related dissections occurred. One minor in-hospital complication (5.9%) and one patient required unplanned re-intervention within 30 days. Conclusions: In this descriptive series, the EBU catheter was successfully employed as a primary or rescue tool in a majority of select ARCA cases, with the highest success in Types A and B. These observations, while not comparative, suggest it is a viable option in the operator’s arsenal for these challenging anatomies and warrant further prospective evaluation.
- 30 December 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (12) , e0326548
Open AccessWhat role should EBU catheters play in the interventional approach to anomalous right coronary arteries? A case series
Background: Percutaneous coronary intervention (PCI) for anomalous right coronary artery (ARCA) remains technically challenging due to variable ostial anatomy. The Extra Back-Up (EBU) catheter, although designed for left coronary interventions, may offer advantages in ARCA PCI, but its performance across anatomical subtypes is not well defined. Methods: This single-center retrospective case series included 17 patients (2019–2024) with ARCA from the left coronary sinus or with high take-off anatomy, in whom an EBU catheter was used. Fourteen patients underwent PCI, one had fractional flow reserve (FFR)-only assessment, and two underwent diagnostic angiography alone. Anatomical subtypes were: Type A (ostium above left coronary artery [LCA]), Type B (below LCA), Type C (midline), or high take-off (≥10 mm above sinotubular junction). Primary outcomes were procedural success (stable engagement, full device delivery, no catheter exchange) and safety. Results: Procedural success with the EBU catheter was 100% in Type A (2/2) and 83.3% in Type B (5/6) when used as the initial guide. In Type C and high take-off anatomies, success was achieved in one of two cases each. EBU was also employed as a second-choice catheter in five patients(one Type A, three Type B, one high take-off) after failed engagement with standard guides catheters. No catheter-related dissections occurred. One minor in-hospital complication (5.9%) and one patient required unplanned re-intervention within 30 days. Conclusions: In this descriptive series, the EBU catheter was successfully employed as a primary or rescue tool in a majority of select ARCA cases, with the highest success in Types A and B. These observations, while not comparative, suggest it is a viable option in the operator’s arsenal for these challenging anatomies and warrant further prospective evaluation.
- 28 October 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (7) , 3982-3991
Efficacy of the EBU Guide Catheter as a Bailout and Selective Strategy in Challenging Right Coronary Artery Interventions
Background: Right coronary artery (RCA) percutaneous coronary intervention (PCI) is often complicated by anatomical factors such as the RCA ostium's variable position within the aortic sinus, the orientation of the proximal RCA segment, aortic root diameter, and lesion complexity that can compromise guide catheter engagement and support. Although the Extra Back‑Up (EBU) catheter is typically used for left coronary interventions, it may have a selective role in RCA PCI, particularly in complex anatomies or as a bailout after failure of standard guides. Methods: We performed a single‐center, retrospective analysis of two cohorts of RCA PCI procedures. The EBU group included 60 RCA PCI procedures performed between 2019 and 2023 where the EBU catheter was used selectively for complex anatomy or after standard catheter failure. The control group comprised 200 consecutive RCA PCI procedues performed in 2023 using standard guide catheters. Primary outcome was catheter success. Secondary outcomes encompassed procedural efficiency and safety endpoints. Results: Catheter success rates did not differ significantly between EBU and standard groups (93.3% vs. 94.5%; p = 0.729), despite a markedly higher prevalence of chronic total occlusions in the EBU cohort (48.3% vs. 15.0%; p < 0.001). Overall complication rates including catheter‐induced dissection, no‐reflow, and general systemic events were low and comparable between cohorts. Operators reported particular EBU utility in low‐sitting and upward‐take‐off RCA ostia. Conclusion: The EBU catheter can be an effective bailout option for RCA PCI after failure of standard guides, demonstrating comparable procedural success and safety in selected appropriate scenarios. Nevertheless, its off‐label use mandates a cautious approach.
- 28 October 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (7) , 3982-3991
Efficacy of the EBU Guide Catheter as a Bailout and Selective Strategy in Challenging Right Coronary Artery Interventions
Background: Right coronary artery (RCA) percutaneous coronary intervention (PCI) is often complicated by anatomical factors such as the RCA ostium's variable position within the aortic sinus, the orientation of the proximal RCA segment, aortic root diameter, and lesion complexity that can compromise guide catheter engagement and support. Although the Extra Back‑Up (EBU) catheter is typically used for left coronary interventions, it may have a selective role in RCA PCI, particularly in complex anatomies or as a bailout after failure of standard guides. Methods: We performed a single‐center, retrospective analysis of two cohorts of RCA PCI procedures. The EBU group included 60 RCA PCI procedures performed between 2019 and 2023 where the EBU catheter was used selectively for complex anatomy or after standard catheter failure. The control group comprised 200 consecutive RCA PCI procedues performed in 2023 using standard guide catheters. Primary outcome was catheter success. Secondary outcomes encompassed procedural efficiency and safety endpoints. Results: Catheter success rates did not differ significantly between EBU and standard groups (93.3% vs. 94.5%; p = 0.729), despite a markedly higher prevalence of chronic total occlusions in the EBU cohort (48.3% vs. 15.0%; p < 0.001). Overall complication rates including catheter‐induced dissection, no‐reflow, and general systemic events were low and comparable between cohorts. Operators reported particular EBU utility in low‐sitting and upward‐take‐off RCA ostia. Conclusion: The EBU catheter can be an effective bailout option for RCA PCI after failure of standard guides, demonstrating comparable procedural success and safety in selected appropriate scenarios. Nevertheless, its off‐label use mandates a cautious approach.
- Open Access
What Role Should EBU Catheters Play in the Interventional Approach to Anomalous Right Coronary Arteries?
Background Percutaneous coronary intervention (PCI) for anomalous right coronary artery (ARCA) remains technically challenging due to variable ostial anatomy. The Extra Back-Up (EBU) catheter, although designed for left coronary interventions, may offer advantages in ARCA PCI, but its performance across anatomical subtypes is not well defined. Methods This single-center retrospective study included 17 patients (2019–2024) with ARCA from the left coronary sinus or with high take-off anatomy, in whom an EBU catheter was used. Fourteen patients underwent PCI, one had FFR-only assessment, and two underwent diagnostic angiography alone. Anatomical subtypes were: Type A (ostium above left coronary artery [LCA]), Type B (below LCA), Type C (midline), or high take-off (≥10 mm above sinotubular junction). Primary outcomes were procedural success (stable engagement, full device delivery, no catheter exchange) and safety. Results Procedural success with the EBU catheter was 100% in Type A (2/2) and 83.3% in Type B (5/6) when used as the initial guide. In Type C and high take-off anatomies, success was achieved in one of two cases each. EBU was also employed as a second-choice catheter in five patients after failed engagement with standard guides catheters. No catheter-related dissections occurred. One minor in-hospital complication (5.9%) and one patient had unplanned Re-intervention within 30 days. Conclusions EBU catheters are effective in ARCA PCI, especially in Type A and B anatomies, but less so in Type C and high take-off variants. These findings support anatomy-tailored guide selection. Multicenter studies are needed to further define role of EBU in this subset.
Open AccessWhat Role Should EBU Catheters Play in the Interventional Approach to Anomalous Right Coronary Arteries?
Background Percutaneous coronary intervention (PCI) for anomalous right coronary artery (ARCA) remains technically challenging due to variable ostial anatomy. The Extra Back-Up (EBU) catheter, although designed for left coronary interventions, may offer advantages in ARCA PCI, but its performance across anatomical subtypes is not well defined. Methods This single-center retrospective study included 17 patients (2019–2024) with ARCA from the left coronary sinus or with high take-off anatomy, in whom an EBU catheter was used. Fourteen patients underwent PCI, one had FFR-only assessment, and two underwent diagnostic angiography alone. Anatomical subtypes were: Type A (ostium above left coronary artery [LCA]), Type B (below LCA), Type C (midline), or high take-off (≥10 mm above sinotubular junction). Primary outcomes were procedural success (stable engagement, full device delivery, no catheter exchange) and safety. Results Procedural success with the EBU catheter was 100% in Type A (2/2) and 83.3% in Type B (5/6) when used as the initial guide. In Type C and high take-off anatomies, success was achieved in one of two cases each. EBU was also employed as a second-choice catheter in five patients after failed engagement with standard guides catheters. No catheter-related dissections occurred. One minor in-hospital complication (5.9%) and one patient had unplanned Re-intervention within 30 days. Conclusions EBU catheters are effective in ARCA PCI, especially in Type A and B anatomies, but less so in Type C and high take-off variants. These findings support anatomy-tailored guide selection. Multicenter studies are needed to further define role of EBU in this subset.