Yi Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yi Huang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- John A. Hossack
University of Virginia
2 shared publications Alexander L. Klibanov
Department of Medicine, Cardiovascular Division and Robert M. Berne Cardiovascular Research Center, University of Virginia, Charlottesville, VA, USA
1 shared publication- Carson Brantley
College of Arts & Sciences, University of Virginia Virginia USA
1 shared publication - Clark Andrew Bs Bonham
Pulmonary and Critical Care, University of Virginia, Charlottesville, VA, United States
1 shared publication - Eibhlin Goggins
University of Virginia
1 shared publication - F. William Mauldin
Rivanna Medical, Charlottesville, VA, USA
1 shared publication
Latest Publications
- 1 August 2025
- Published by American Physiological Society in American Journal of Physiology-Renal Physiology
- Vol. 329 (2) , F234-F249
Pulsed ultrasound targeted to the spleen mitigates against kidney injury and promotes kidney repair
We developed a safe and effective pulsed ultrasound (pUS) protocol targeting the mouse spleen to block inflammation and reduce AKI of multiple etiologies. By using a model of the AKI to CKD transition, we demonstrated the long-term benefits of pUS. The findings of these studies will be used to advance the human translation of spleen-targeted US as a preventative measure for AKI and CKD.
- 1 August 2025
- Published by American Physiological Society in American Journal of Physiology-Renal Physiology
- Vol. 329 (2) , F234-F249
Pulsed ultrasound targeted to the spleen mitigates against kidney injury and promotes kidney repair
We developed a safe and effective pulsed ultrasound (pUS) protocol targeting the mouse spleen to block inflammation and reduce AKI of multiple etiologies. By using a model of the AKI to CKD transition, we demonstrated the long-term benefits of pUS. The findings of these studies will be used to advance the human translation of spleen-targeted US as a preventative measure for AKI and CKD.
- 4 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (4) , 445-459
High-Resolution Ultrasound Molecular Imaging With Incremental Burst Sequence: In Vitro and in Vivo Validation
Ultrasound localization microscopy (ULM) enables super-resolution ultrasound (SRUS) imaging of microvasculature, while ultrasound molecular imaging (USMI) characterizes molecular signatures using microbubbles (MBs) targeted to specific biomarkers. Although the co-localization of SRUS and USMI has been demonstrated previously, USMI resolution is limited by ultrasound diffraction-based effects and does not match the super-resolved microvasculature. This study introduces the Incremental Burst Sequence (IBS) method to induce the population of polydisperse targeted MBs to burst progressively, achieving MBs spatial separation and enabling high-resolution USMI (HR-USMI) localization. IBS method employs interleaved imaging and bursting pulses, with transmit voltages of bursting pulses incrementally increased to produce a gradual rise in the acoustic pressure. IBS is first validated optically in vitro using a cellulose tubing phantom, and MB remaining count during IBS is measured. Thereafter, in vivo validation is performed in a murine tumor model, and the intra-tumoral targeted MB signal intensity is measured during IBS. Furthermore, high frame-rate data for SRUS and IBS data for HR-USMI are acquired from a single bolus injection of MBs to generate composite images with high-resolution molecular signatures superimposed on the tumor microvasculature. Both in vitro and in vivo results validate the technical feasibility of the proposed IBS method. In addition, we demonstrate that higher bursting pulse repetitions lead to a faster disruption of the MB population during IBS. Finally, HR-USMI signals localized within a 50 μm × 50 μm grid are aligned with microvessels resolved better than 100 μm, presenting a combination of molecular signatures and anatomical structures at fine resolution.
- 4 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (4) , 445-459
High-Resolution Ultrasound Molecular Imaging With Incremental Burst Sequence: In Vitro and in Vivo Validation
Ultrasound localization microscopy (ULM) enables super-resolution ultrasound (SRUS) imaging of microvasculature, while ultrasound molecular imaging (USMI) characterizes molecular signatures using microbubbles (MBs) targeted to specific biomarkers. Although the co-localization of SRUS and USMI has been demonstrated previously, USMI resolution is limited by ultrasound diffraction-based effects and does not match the super-resolved microvasculature. This study introduces the Incremental Burst Sequence (IBS) method to induce the population of polydisperse targeted MBs to burst progressively, achieving MBs spatial separation and enabling high-resolution USMI (HR-USMI) localization. IBS method employs interleaved imaging and bursting pulses, with transmit voltages of bursting pulses incrementally increased to produce a gradual rise in the acoustic pressure. IBS is first validated optically in vitro using a cellulose tubing phantom, and MB remaining count during IBS is measured. Thereafter, in vivo validation is performed in a murine tumor model, and the intra-tumoral targeted MB signal intensity is measured during IBS. Furthermore, high frame-rate data for SRUS and IBS data for HR-USMI are acquired from a single bolus injection of MBs to generate composite images with high-resolution molecular signatures superimposed on the tumor microvasculature. Both in vitro and in vivo results validate the technical feasibility of the proposed IBS method. In addition, we demonstrate that higher bursting pulse repetitions lead to a faster disruption of the MB population during IBS. Finally, HR-USMI signals localized within a 50 μm × 50 μm grid are aligned with microvessels resolved better than 100 μm, presenting a combination of molecular signatures and anatomical structures at fine resolution.