TITakamasa Ishikawa

Takamasa Ishikawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Takamasa Ishikawa has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Crista Caval Line: Lattice‐Tip Pulsed Field Ablation for Right Atrial Substrate Modification

    by Shuhei Arai, Yuya Nakamura, Rimpei Ueno, Yosuke Kai, Masaya Ochiai, Takamasa Ishikawa, Haruka Miyazaki, Kosuke Yoshikawa, Taku Asano, Toshiro Shinke

    Introduction: Pulmonary vein isolation remains central to atrial fibrillation (AF) ablation, yet right atrial substrate modification remains incompletely defined. The crista terminalis (CT) region lies close to the right phrenic nerve and may exhibit anisotropic conduction and native or functional conduction block, while also serving as a potential non‐pulmonary‐vein trigger site. We evaluated the acute feasibility and electroanatomic endpoint of the Crista Caval Line (CCL), a CT‐guided, sinoatrial node (SN)–sparing lesion set created with lattice‐tip pulsed field ablation (PFA). Methods and Results: We prospectively enrolled 36 consecutive patients undergoing CCL creation during repeat AF ablation or ablation for non‐paroxysmal AF. Pre‐CCL sinus‐rhythm high‐density right atrial activation mapping was performed in all patients. CT‐related conduction delay or block was observed in 27 patients (75.0%). In 14 patients (38.9%) with an apparent CT block line, the inferior application‐set edge was aligned to the block line; in the remaining 22 patients without an apparent block, placement was primarily guided by intracardiac echocardiography. The CCL was positioned posterior to the CT, with the lateral margin of its superior application set kept approximately 15 mm posterolateral to the earliest mapped sinus activation site for SN protection. The CCL measured 78.8 [66.4–86.0] mm from first to last tag and required 26 [22–30] PFA applications over 370 [282–481] s. First‐pass bidirectional transverse conduction block was confirmed in all patients by postablation activation mapping and differential pacing from both sides of the CCL. Next‐day inspiratory/expiratory chest radiography showed no abnormality suggestive of phrenic nerve palsy; no pacemaker‐requiring SN dysfunction or other clinically apparent collateral injury occurred. Conclusions: A CT‐guided, SN‐sparing CCL can be reproducibly created with lattice‐tip PFA, producing a first‐pass bidirectional transverse conduction block without clinically apparent phrenic nerve palsy. These findings establish acute feasibility and an electroanatomic endpoint; lesion durability, arrhythmia recurrence, and incremental clinical benefit require further study.

  • Open Access

    Ventricular Pacing Inhibition After Dual‐Chamber Leadless Pacing Associated With a Retained Right Ventricular Lead

    by Yuya Nakamura, Takamasa Ishikawa, Shuhei Arai, Kosuke Yoshikawa, Taku Asano, Toshiro Shinke

    An 88‐year‐old pacemaker‐dependent man with a retained low‐impedance, noise‐producing right ventricular lead underwent implantation of a dual‐chamber leadless pacemaker. On postoperative day 1, he developed recurrent syncope with pauses up to 13 s. Although stored electrograms from the index events were unavailable, post‐event interrogation showed atrial pacing followed by ventricular safety pacing, and provocative testing supported persistent electrical coupling involving the retained lead. After reduction of temporary high‐output settings and reprogramming to VDD, syncope did not recur during 12 months. Retained malfunctioning leads may mediate timing‐dependent ventricular inhibition after dual‐chamber leadless pacing.

  • Open Access

    Case of Frozen Leads: An Old but Persistent Challenge

    by Takamasa Ishikawa, Yuya Nakamura, Yosuke Kai, Rimpei Ueno, Yoshikazu Suzuki, Masaya Ochiai, Hiroto Sugiyama, Yoshimi Onishi, Taku Asano, Toshiro Shinke

    Frozen leads are a rare but clinically relevant complication during cardiac device replacement. A 77‐year‐old man undergoing pacemaker upgrade had atrial and ventricular leads firmly adhered to the generator header despite set screw removal and ethanol application. As specialized extraction tools were unavailable, an orthopedic nipper and forceps were used as a locking mechanism to dismantle the header, successfully freeing the leads without damage. This is the first reported case in which fully exposed lead pins could not be extracted. While adhesion limited to the pin port may be addressed with ethanol or fine needles, adhesion from the lead base requires header destruction, increasing damage risk. Specialized tools may not always be available, and in such scenarios, the described method may serve as a practical alternative. Thus, this case underscores the critical importance of meticulous blood and fluid removal during cardiac implantable electronic device (CIED) implantation to prevent frozen leads.

  • Open Access

    Cardiac Resynchronization Therapy in a Patient with PR Prolongation and Nonspecific Intraventricular Conduction Delay

    by Yuya Nakamura, Yousuke Kai, Rinpei Ueno, Yoshikazu Suzuki, Masaya Ochiai, Takamasa Ishikawa, Shuhei Arai, Yoshimi Onishi, Taku Asano, Toshiro Shinke

    Cardiac resynchronization therapy (CRT) improves outcomes in heart failure patients with left bundle branch block (LBBB), but its efficacy in patients with nonspecific intraventricular conduction delay (NICD) and prolonged PR interval remains uncertain. We present a 69-year-old male with NICD who was successfully treated with individualized atrioventricular (AV) delay optimization using SyncAV™ Plus. This approach resulted in QRS narrowing, echocardiographic improvement, and catecholamine withdrawal. The patient remained stable for two years. This case underscores the role of advanced AV delay programming in optimizing CRT outcomes for NICD patients with PR prolongation.