Bin Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bin Liu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Bingyu Mei
College of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443000, China
1 shared publication Junjun Xiong
China Electric Power Research Institute
1 shared publication- Junjun Xiong
China Electric Power Research Institute, Wuhan 430074, China
1 shared publication - Xiaopin Deng
China Electric Power Research Institute, Wuhan 430074, China
1 shared publication Xiaozhou Wang
China Electric Power Research Institute
1 shared publication- Xueyou Zhang
State Grid Anhui Electric Power Co., Ltd., Super High Voltage Branch, Hefei 230000, China
1 shared publication
Latest Publications
- 23 June 2026
- Published by Springer Nature
- p. 716-727
Performance Testing and Failure Analysis of Fiber-Optic Current Transformers Under Extreme Environment
- 23 June 2026
- Published by Springer Nature
- p. 716-727
Performance Testing and Failure Analysis of Fiber-Optic Current Transformers Under Extreme Environment
- Open Access
Equivalent Modeling of Disconnector Operation Based on Dynamic Arc Characteristics and VFTO Characteristic Analysis
To thoroughly analyze the high-frequency and high-amplitude electromagnetic disturbances generated during disconnector operation, this paper proposes an equivalent modeling approach based on dynamic arc behavior. The model incorporates the resistance, inductance, and capacitance characteristics of the arc and consists of four main modules: arc reignition, arc extinction, arc resistance control, and switch control. Complete logical coordination among these modules is designed to enhance the model’s performance in terms of dynamic response and modeling accuracy compared to traditional methods. By systematically comparing simulation results with experimental data and conventional model outputs, the effectiveness and reliability of the proposed model in accurately reflecting the operational characteristics of disconnectors are validated. Furthermore, a comparative analysis of transient waveform characteristics from both experiment and simulation is conducted, with key parameters extracted and probability density functions constructed. The results demonstrate the high-precision fitting capability of the model and further reveal the statistical distribution patterns of very fast transient overvoltage single-pulse characteristics.
Open AccessEquivalent Modeling of Disconnector Operation Based on Dynamic Arc Characteristics and VFTO Characteristic Analysis
To thoroughly analyze the high-frequency and high-amplitude electromagnetic disturbances generated during disconnector operation, this paper proposes an equivalent modeling approach based on dynamic arc behavior. The model incorporates the resistance, inductance, and capacitance characteristics of the arc and consists of four main modules: arc reignition, arc extinction, arc resistance control, and switch control. Complete logical coordination among these modules is designed to enhance the model’s performance in terms of dynamic response and modeling accuracy compared to traditional methods. By systematically comparing simulation results with experimental data and conventional model outputs, the effectiveness and reliability of the proposed model in accurately reflecting the operational characteristics of disconnectors are validated. Furthermore, a comparative analysis of transient waveform characteristics from both experiment and simulation is conducted, with key parameters extracted and probability density functions constructed. The results demonstrate the high-precision fitting capability of the model and further reveal the statistical distribution patterns of very fast transient overvoltage single-pulse characteristics.