Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Edgar Williams Villanueva Martinez has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Forward Osmosis for Sustainable Brackish Water Desalination

    by Juan Taumaturgo Medina Collana, Edgar Williams Villanueva Martinez, Kevin Remigio Azorza Gillen, Luis Américo Carrasco Venegas, César Augusto Rodríguez Aburto, César Augusto Santos Mejía, Pablo Manuel Morcillo Valdivia, Jorge Alberto Montaño Pisfil, Rodolfo Paz Salazar, Fredy Andrés Taipe Castro

    The desalination of brackish and seawater has emerged as a critical strategy to address growing water scarcity in regions experiencing water stress, particularly within the context of sustainable water resource management. Among available technologies, forward osmosis (FO) has gained increasing attention due to its potential for lower energy consumption and reduced environmental impact compared to conventional desalination processes. In this study, commercial HFFO2 (Aquaporin Inside) membrane from FO was used. A complete factorial design with three factors was used: feed solution concentration (1.5 and 3 g/L NaCl), draw solution concentration (15, 25, and 35 g/L NaCl), and feed solution flow rate (600 and 1000 mL/min) on the percentage of recovery and water flux. Tests showed that as the feed concentration decreases from 3 to 1.5 g/L of NaCl, water recovery improves by 23.6%. The results revealed that increasing the concentration of the draw solution from 15 to 25 g/L of NaCl increased water recovery by 22.2%. However, for a concentration variation of 25 to 35 g/L, this increase is insignificant at 0.92%. The results showed that, with a concentration of 1.5 g/L of NaCl, a feed flow rate of 1000 mL/min, and a concentration of 25 g/L of NaCl as the draw solution, a higher water recovery rate (95.4839%) was achieved. Similarly, average water flux values of 2.18, 2.43, and 2.68 Lm−2h−1 were observed when using draw solutions of 15, 25, and 35 g/L of NaCl, respectively. In addition, increasing the FS flow rate slightly reduces water recovery (from 76.04% to 74.06%). Consequently, the forward osmosis process has proven to be effective, practical, viable, and environmentally friendly for water desalination, as well as being applicable to the treatment of wastewater with high electrical conductivity.

  • Open Access

    Obtaining Biodiesel from Soybean Vegetable Oil Using a Hydrodynamic Cavitation Reactor

    by Luz Clara Andia-Marron, Jessica Abad-Salcca, Juan Taumaturgo Medina-Collana, Edgar Williams Villanueva-Martinez, Jorge Amador López-Herrera, Richard Brandon Guevara-Salcedo, Leonard Ordoñez-Santa Maria, Rodolfo Paz-Salazar, Fredy Andrés Taipe-Castro, Jorge Alberto Montaño-Pisfil, et al.

    Hydrodynamic cavitation (HC) is an efficient technique for biodiesel production. The main contribution of this study is the development of a modular reactor with a universal stainless steel joint, whose design facilitates the installation, replacement, and maintenance of the orifice plate by eliminating flanges and bolts during assembly. Using this reactor, the study evaluated the synergistic interaction between feed pressure and methanol:oil molar ratio in the transesterification of soybean oil, employing a 32 factorial design. The orifice plate was 3 mm thick and had 19 holes with a diameter of 1.0 mm, installed downstream of the pump. The process was carried out for 45 min, using NaOH at 1 wt% relative to the oil and at 60 ± 5 °C. Feed pressures of 1.72, 2.41, and 3.10 bar and methanol:oil molar ratios of 6:1, 8:1, and 10:1 were evaluated, reaching a maximum yield of 92.98% at 3.10 bar and 8:1. Analysis of variance (ANOVA) confirmed a significant interaction (p < 0.0001) and allowed a second-order polynomial model to be fitted (R2 = 0.9981). In contrast, conventional mechanical agitation required 90 min to achieve 95% yield. The biodiesel produced met most American Society for Testing and Materials (ASTM) D6751 requirements, confirming the potential of HC as a viable alternative for intensifying biodiesel production.


  • Open Access

    Electrochemical Production of Hypochlorous Acid and Sodium Hydroxide Using Ion Exchange Membranes

    by Juan Taumaturgo Medina Collana, Kevin Azorza Guillen, Edgar Williams Villanueva Martinez, Carlos Ancieta Dextre, Luis Carrasco Venegas, Oscar Rodriguez Taranco, Jorge Lopez Herrera, Pablo Diaz Bravo, Jose Porlles Loarte, Jorge Montaño Pisfil

    Given the problems related to drinking water supplies in rural and economically disadvantaged regions, point-of-use disinfection technologies are a viable alternative to improve access to drinking. Electrochlorinators are devices that produce chlorine-based disinfectants onsite via the electrolysis of a sodium chloride solution. In this research, we have constructed an innovative laboratory-scale three-compartment cell that includes two ion exchange membranes, fixed between two electrodes; in the anodic compartment, an acidic mixture of chlorine-based species (Cl2, HClO, HCl and ClO−) is obtained, and, in the cathodic compartment, an alkaline solution is present (NaOH and hydrogen gas), while the central compartment is fed with a sodium chloride solution. The Taguchi methodology was used to examine the impact of the process operating conditions on the results obtained. The effects of the electrical potential levels (4.5, 6 and 7 V), electrolysis times (30, 60 and 90 min) and initial sodium chloride concentrations (5, 15 and 30 g/L) on the physical and chemical characteristics (concentrations of available chlorine and sodium hydroxide and pH of the solutions) and energy consumption were investigated. Variations in the electrical potential significantly influenced the concentration levels of active chlorine and sodium hydroxide produced, as well as the pH values of the respective solutions. The most favorable conditions for the production of electrolyzed water were an electrical potential of 7 volts, an electrolysis time of 90 min and a concentration of 30 g/L of sodium chloride, which was verified by ANOVA. The maximum concentration of active chlorine reached 290 mg/L and that of sodium hydroxide reached 1450 mg/L without the presence of hypochlorite ions under the best synthesis conditions. The energy consumption was 18.6 kWh/kg Cl2 and 4.4 kWh/kg NaOH, while the average electric current efficiency for sodium hydroxide formation reached 88.9%. Similarly, the maximum conversion of chloride ions reached 24.37% under the best operating conditions.