HMHaoyu Meng

Haoyu Meng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haoyu Meng has a total of 23 co-authors. Here are the top co-authors by number of shared publications:

  • Chao Liu

    Ningxia Hui Autonomous Region Hospital of Traditional Chinese Medicine, Ningxia Hui Autonomous Region Academy of Traditional Chinese Medicine, Yinchuan, China.

    1 shared publication
  • Dengqing Shi

    Department of Cardiology , The First Affiliated Hospital with Nanjing Medical University, Nanjing, China

    1 shared publication
  • Di Zhao

    The Second Clinical Medical College, Nanjing Medical University, Nanjing, China

    1 shared publication
  • Jiabao Liu

    Department of Cardiovascular Medicine The First Affiliated Hospital of Nanjing Medical University Nanjing Jiangsu Province China

    1 shared publication
  • Jingsong Xia

    Department of Cardiology , The First Affiliated Hospital with Nanjing Medical University, Nanjing, China

    1 shared publication
  • Jun Zhang

    Department of Cardiology, Northern Jiangsu People’s Hospital, Yangzhou, China

    1 shared publication

Latest Publications

  • Open Access

    Coronary plaque phenotypes, inflammation and cardiovascular prognosis in metabolic dysfunction-associated steatotic liver disease

    by Jun Zhang, Yingqiang Du, Tianqing Cao, Keyu Dai, Xianglin Tang, Yinliang Li, Weifeng Guo, Haoyu Meng, Yong Xie, Neng Dai

  • Open Access

    Deep learning predicts stent implantation in borderline coronary lesions from angiography

    by Jingsong Xia, Di Zhao, Yiming Zhang, Leilei Chen, Zhenhua Yang, Dengqing Shi, Chao Liu, Haoyu Meng, Liansheng Wang, Jiabao Liu

    Accurate evaluation of coronary intermediate lesions (50–70% stenosis) is essential for stent decision-making, yet conventional angiography remains subjective and adjunctive tests like FFR are often invasive or costly. In this retrospective multicenter study of 1298 patients, we developed an attention-enhanced deep learning model using Improved_EfficientNet with a Convolutional Block Attention Module to predict stent necessity directly from coronary angiography images. The model utilized multimodal labels from FFR, IVUS, and OCT as reference standards during training. In internal validation, the model achieved an accuracy of 0.976 and an F1-score of 0.971. External validation across independent institutions demonstrated robust performance with an accuracy of 0.807 and an AUC of 0.897. Grad-CAM visualization confirmed that the model focuses on clinically relevant stenotic regions, showing high alignment with expert interpretations. These results suggest that the proposed model can effectively integrate anatomical and functional information to provide real-time decision support, potentially reducing the need for invasive adjunctive testing and enhancing precision in interventional cardiology.

  • Open Access

    Association between optical coherence tomography and functionally severe stenosis assessed by quantitative flow ratio in coronary intermediate lesions

    by Yuan Xue, Yuchen Zhang, Peng Wu, Yang Yang, Xin Lu, Haoyu Meng

    Background: Stenosis severity for an intermediate coronary lesion (ICL) demands comprehensive assessment methods. The relationship between optical coherence tomography (OCT) and coronary stenosis evaluated by quantitative flow ratio (QFR) remains to be discussed. Objective: To investigate the association between OCT parameters and coronary functionally significant stenosis identified by QFR in patients with ICL. Methods: A total of 113 patients with 115 target vessels were assessed using both OCT and QFR measurements for ICL. ICL was defined as a coronary lesion according to visual estimation with a diameter stenosis between 50% and 90%. Functional relevance stenosis was considered severe when QFR ≤ 0.80. Results: The mean age of the included patients was 62.2 years, and the overall median QFR was 0.82. The mean minimal lumen area (MLA) and area stenosis (AS) assessed by OCT were 3.11 mm2 and 68.4%, respectively. According to the cut-off value of QFR = 0.80, the vessels with hemodynamic ischemia (n = 55) or without ischemia (n = 60) were grouped. OCT-measured MLA and AS exhibited a moderate diagnostic value with an area under the curve (AUC) of 0.83 (95% CI 0.75 to 0.90) for MLA and 0.87 (95% CI 0.81 to 0.94) for AS, respectively. The optimal cutoff value exhibited by OCT-measured anatomical parameters for identifying coronary stenosis, represented by QFR ≤ 0.80 was 2.52 mm2 (sensitivity 71%, specificity 85%) for MLA and 69% (sensitivity 84%, specificity 78%) for AS. Subsequently, AS measured by QFR and OCT were evaluated using linear regression analysis, revealing a good correlation (r = 0.79, p<0.001). Conclusions: Intraluminal anatomical parameters obtained by OCT showed moderate diagnostic value for predicting the functional ischemia evaluated by QFR. Additionally, QFR may offer a rapid and simple method to assess area stenosis in coronary intermediate lesions.