Alberto Ñancupil-Andrade
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alberto Ñancupil-Andrade has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Héctor Fuentes-Barría
School of Dentistry Universidad Andrés Bello Concepción Chile
2 shared publications - Jorge Leschot-Gatica
Escuela de Ciencias de la Actividad Física, Facultad de Salud y Ciencias Sociales, Universidad de las Américas, Concepción 4030000, Chile
2 shared publications - Víctor Garrido-Osorio
Escuela de Ciencias de la Actividad Física, Facultad de Salud y Ciencias Sociales, Universidad de las Américas, Concepción 4030000, Chile
2 shared publications - Alejandro Pérez-Castilla
Department of Education, Faculty of Education Sciences, University of Almería, Almería, Spain
1 shared publication - Andre Renato Quispe Fajardo
Facultad de Ciencias Humanas, Escuela de Educación, Carrera de Entrenador en Actividad Física y Deporte, Universidad Bernardo O’Higgins, Avenida Viel 1497, Santiago 8370993, Chile
1 shared publication - Carolina López Mayoral
Khalifa Combat, Cuauhtémoc Branch, Mexico City 06920, Mexico
1 shared publication
Latest Publications
- Open Access
- 3 November 2026
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 11 (4) , 460
Kinanthropometric Profiles and Neuromuscular Performance in Professional Male Boxers: Relationships Between Body Composition, Proportionality, and Force Expression
Background and Objectives: This cross-sectional study examined associations between kinanthropometric indicators and lower-body force-time performance in 34 professional male boxers. Athletes were recruited by convenience sampling; no a priori sample-size calculation was performed. Methods: CMJ, countermovement rebound jump, and isometric-squat outcomes were assessed using a force platform. Three missing derived anthropometric estimates were recalculated from recorded measurements, and site-specific corrected-girth calculations, the Rocha bone-mass equation, and the Kerr adipose-mass input were corrected following confirmation by the study anthropometry investigator. A matrix of 117 Spearman correlations was evaluated with Benjamini–Hochberg false-discovery-rate adjustment. Results: CMJ peak force was correlated with BMI (rho = 0.697), body mass (rho = 0.663), corrected girths (rho = 0.622), estimated muscle mass (rho = 0.573), and adipose mass (rho = 0.508). Isometric-squat peak force was correlated with corrected girths (rho = 0.651), estimated muscle mass (rho = 0.638), sitting height (rho = 0.547), and estimated bone mass (rho = 0.521). Thirteen of 117 exploratory associations survived FDR correction. Conclusions: In this exploratory sample, observed relationships with absolute force tended to be larger than those with relative, ballistic, or time-dependent outputs, but formal differences between dependent correlations were not tested. The observed associations, including those based on anthropometric tissue-mass estimates, do not establish causal or body-mass-independent effects.
- 3 November 2026
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 11 (4) , 460
Open AccessKinanthropometric Profiles and Neuromuscular Performance in Professional Male Boxers: Relationships Between Body Composition, Proportionality, and Force Expression
Background and Objectives: This cross-sectional study examined associations between kinanthropometric indicators and lower-body force-time performance in 34 professional male boxers. Athletes were recruited by convenience sampling; no a priori sample-size calculation was performed. Methods: CMJ, countermovement rebound jump, and isometric-squat outcomes were assessed using a force platform. Three missing derived anthropometric estimates were recalculated from recorded measurements, and site-specific corrected-girth calculations, the Rocha bone-mass equation, and the Kerr adipose-mass input were corrected following confirmation by the study anthropometry investigator. A matrix of 117 Spearman correlations was evaluated with Benjamini–Hochberg false-discovery-rate adjustment. Results: CMJ peak force was correlated with BMI (rho = 0.697), body mass (rho = 0.663), corrected girths (rho = 0.622), estimated muscle mass (rho = 0.573), and adipose mass (rho = 0.508). Isometric-squat peak force was correlated with corrected girths (rho = 0.651), estimated muscle mass (rho = 0.638), sitting height (rho = 0.547), and estimated bone mass (rho = 0.521). Thirteen of 117 exploratory associations survived FDR correction. Conclusions: In this exploratory sample, observed relationships with absolute force tended to be larger than those with relative, ballistic, or time-dependent outputs, but formal differences between dependent correlations were not tested. The observed associations, including those based on anthropometric tissue-mass estimates, do not establish causal or body-mass-independent effects.
- Open Access
- 22 January 2026
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 11 (1) , 47
Effects of Knee Sleeve Density on Theoretical Neuromuscular Capacities Derived from the Force–Velocity–Power Profile in the Back Squat
Background: Neoprene knee sleeves are commonly used to enhance joint stability and mechanical performance during resistance training. However, the specific influence of sleeve density on the force–velocity–power (F–V–P) profile during multi-joint lower-body exercises such as the back squat remains unclear. This study aimed to compare the theoretical F–V–P parameters derived from back squat performance while wearing low-density (LD) versus high-density (HD) knee sleeves. Methods: Fifteen resistance-trained males completed an incremental back squat test under both LD and HD conditions. A linear position transducer recorded barbell displacement and velocity. Individual force–velocity relationships were modelled to determine maximal theoretical force (F0), velocity (V0), power (Pmax), and the F–V slope. Paired-sample t-tests, linear mixed models, and Cohen’s d effect sizes were calculated. Clinical relevance was assessed using a threshold defined as 0.2 × the standard deviation of the HD condition. Bayesian analyses were conducted to estimate the probability and magnitude of the observed effects. Results: No statistically significant differences were observed between sleeve conditions for F0, V0, Pmax, or F–V slope (p > 0.05, d ≤ 0.37). Nonetheless, HD sleeves yielded slightly higher mean values for F0, V0, and Pmax, exceeding the predefined threshold for practical relevance. Bayesian models showed moderate probabilities (~0.80) that HD sleeves outperformed LD, though with limited chances of crossing the clinical significance threshold. Conclusions: Although HD sleeves do not produce systematic changes in F–V–P parameters, their increased material stiffness may provide small yet practically meaningful mechanical advantages in high-force resistance training contexts.
- 22 January 2026
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 11 (1) , 47
Open AccessEffects of Knee Sleeve Density on Theoretical Neuromuscular Capacities Derived from the Force–Velocity–Power Profile in the Back Squat
Background: Neoprene knee sleeves are commonly used to enhance joint stability and mechanical performance during resistance training. However, the specific influence of sleeve density on the force–velocity–power (F–V–P) profile during multi-joint lower-body exercises such as the back squat remains unclear. This study aimed to compare the theoretical F–V–P parameters derived from back squat performance while wearing low-density (LD) versus high-density (HD) knee sleeves. Methods: Fifteen resistance-trained males completed an incremental back squat test under both LD and HD conditions. A linear position transducer recorded barbell displacement and velocity. Individual force–velocity relationships were modelled to determine maximal theoretical force (F0), velocity (V0), power (Pmax), and the F–V slope. Paired-sample t-tests, linear mixed models, and Cohen’s d effect sizes were calculated. Clinical relevance was assessed using a threshold defined as 0.2 × the standard deviation of the HD condition. Bayesian analyses were conducted to estimate the probability and magnitude of the observed effects. Results: No statistically significant differences were observed between sleeve conditions for F0, V0, Pmax, or F–V slope (p > 0.05, d ≤ 0.37). Nonetheless, HD sleeves yielded slightly higher mean values for F0, V0, and Pmax, exceeding the predefined threshold for practical relevance. Bayesian models showed moderate probabilities (~0.80) that HD sleeves outperformed LD, though with limited chances of crossing the clinical significance threshold. Conclusions: Although HD sleeves do not produce systematic changes in F–V–P parameters, their increased material stiffness may provide small yet practically meaningful mechanical advantages in high-force resistance training contexts.
- Open Access
- 22 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12409
Validation of the G-Force Platform for Isometric Tests in Physically Active Young Adults: A Pilot Study
Objectives: To evaluate the validity, accuracy, and reliability of the G-Force force platform during isometric tests, through comparison with a gold-standard force platform in physically active young adults. Methods: Nine physically active participants (23.67 ± 4.97 years; body mass index: 25.79 ± 3.02 kg/m2) performed isometric posterior lower limb muscle tests per leg, following a standardized warm-up and familiarization protocol. The G-Force platform and compared against a gold-standard device, the Valkyria Trainer Balance (VTB) force platform. The measured variables included Peak Force and peak rate of force development (RFD) at 50, 100 and 150 ms (RFD50, RFD100 and RFD150). Intra- and inter-platform reliability were assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV%), Bland–Altman analysis and Pearson’s correlation coefficients between both platforms. Results: Peak Force showed excellent intra-platform repeatability (ICC = 0.86–0.91) and moderate-to-good inter-platform reliability (ICC = 0.75–0.77), with the G-Force platform generally reporting slightly lower absolute values than VTB. RFD measures demonstrated moderate reproducibility (ICC = 0.75–0.87) and higher variability (CV = 47–57%). Bland–Altman analyses revealed minimal bias for Peak Force, while regression analyses indicated strong, significant associations between G-Force and VTB measurements (R2 = 0.55–0.77; β = 0.74–0.88; p < 0.05). Conclusions: The G-Force force platform is a valid, reliable, and low-cost tool for assessing isometric strength in physically active young adults.
- 22 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12409
Open AccessValidation of the G-Force Platform for Isometric Tests in Physically Active Young Adults: A Pilot Study
Objectives: To evaluate the validity, accuracy, and reliability of the G-Force force platform during isometric tests, through comparison with a gold-standard force platform in physically active young adults. Methods: Nine physically active participants (23.67 ± 4.97 years; body mass index: 25.79 ± 3.02 kg/m2) performed isometric posterior lower limb muscle tests per leg, following a standardized warm-up and familiarization protocol. The G-Force platform and compared against a gold-standard device, the Valkyria Trainer Balance (VTB) force platform. The measured variables included Peak Force and peak rate of force development (RFD) at 50, 100 and 150 ms (RFD50, RFD100 and RFD150). Intra- and inter-platform reliability were assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV%), Bland–Altman analysis and Pearson’s correlation coefficients between both platforms. Results: Peak Force showed excellent intra-platform repeatability (ICC = 0.86–0.91) and moderate-to-good inter-platform reliability (ICC = 0.75–0.77), with the G-Force platform generally reporting slightly lower absolute values than VTB. RFD measures demonstrated moderate reproducibility (ICC = 0.75–0.87) and higher variability (CV = 47–57%). Bland–Altman analyses revealed minimal bias for Peak Force, while regression analyses indicated strong, significant associations between G-Force and VTB measurements (R2 = 0.55–0.77; β = 0.74–0.88; p < 0.05). Conclusions: The G-Force force platform is a valid, reliable, and low-cost tool for assessing isometric strength in physically active young adults.
- Open Access
- 10 June 2025
- Published by Asociacion Espanola de Analisis del Rendimiento Deportivo in Journal of Human Sport and Exercise
- Vol. 20 (3) , 1086-1093
The influence of menstrual cycle in heart rate variability and performance
Introduction: Heart rate variability (HRV) is a non-invasive marker of the autonomic nervous system (ANS) that provides insights into physiological responses to training. This study investigates the relationship between HRV and athletic performance with and without the menstrual cycle (MC) in a highly-trained female long-distance runner. Methods: A 24-year-old elite female long-distance runner participated in this quantitative case study. HRV was recorded daily using a Polar H10 chest strap over three months, both with and without the MC. Athletic performance was assessed through mean power output (MPO) during 3-minute time trials (TT) using a Stryd inertial sensor. Four evaluations were conducted: two without MC and two with MC. Results: A nearly perfect correlation was found between HRV (rolling RMSSD) and MPO during the first TT without MC (r = 0.969, p ≤ .001). However, no significant correlations were observed during the second TT with MC, the third TT without MC, or the fourth TT with MC. These findings suggest that HRV is a reliable marker for predicting athletic performance in the absence of MC but is influenced by hormonal fluctuations during the MC. Conclusion: HRV monitoring is a valuable tool for assessing internal load and predicting performance in female athletes. However, its reliability can be affected by the menstrual cycle and by accumulated fatigue. Future research should explore larger sample sizes and the impact of contraceptives on HRV and performance.
- 10 June 2025
- Published by Asociacion Espanola de Analisis del Rendimiento Deportivo in Journal of Human Sport and Exercise
- Vol. 20 (3) , 1086-1093
Open AccessThe influence of menstrual cycle in heart rate variability and performance
Introduction: Heart rate variability (HRV) is a non-invasive marker of the autonomic nervous system (ANS) that provides insights into physiological responses to training. This study investigates the relationship between HRV and athletic performance with and without the menstrual cycle (MC) in a highly-trained female long-distance runner. Methods: A 24-year-old elite female long-distance runner participated in this quantitative case study. HRV was recorded daily using a Polar H10 chest strap over three months, both with and without the MC. Athletic performance was assessed through mean power output (MPO) during 3-minute time trials (TT) using a Stryd inertial sensor. Four evaluations were conducted: two without MC and two with MC. Results: A nearly perfect correlation was found between HRV (rolling RMSSD) and MPO during the first TT without MC (r = 0.969, p ≤ .001). However, no significant correlations were observed during the second TT with MC, the third TT without MC, or the fourth TT with MC. These findings suggest that HRV is a reliable marker for predicting athletic performance in the absence of MC but is influenced by hormonal fluctuations during the MC. Conclusion: HRV monitoring is a valuable tool for assessing internal load and predicting performance in female athletes. However, its reliability can be affected by the menstrual cycle and by accumulated fatigue. Future research should explore larger sample sizes and the impact of contraceptives on HRV and performance.