Hualei Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hualei Zheng has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Fei Xu
Hebei university of Technology
4 shared publications - Xian Zhang
Hebei university of Technology
3 shared publications - Zhixin Chen
Hebei university of Technology
3 shared publications - Chi Kong Tse
City University of Hong Kong
1 shared publication - Xiaoning Li
State Key Lab of the Intelligent Power Distribution Equipment and System, China
1 shared publication - Xiquan Deng
State Key Laboratory of Intelligent Power Distribution Equipment and System, Hebei University of Technology, Tianjin, China
1 shared publication
Latest Publications
- 13 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 6939-6950
Multiobjective Optimization With Minimum Output Error and Maximum Efficiency for WPT Systems Based on Discrete Neighborhood Search–Model Predictive Control Scheme
Traditional control schemes for wireless power transfer (WPT) systems struggle to achieve zero voltage switching (ZVS), output stability, and efficiency optimization simultaneously. To address this limitation, this article proposes a discrete neighborhood search–model predictive control (DNS-MPC) strategy for multiobjective optimization in inductor-capacitor-capacitor-series (LCC-S) compensated WPT systems, addressing three critical requirements: output regulations, transmission efficiency maximization, and ZVS realization. First, a mathematical model of the WPT system is developed based on circuit analysis. The derived expressions are then used to identify the operating regions that ensure ZVS across all power switches. Second, a composite cost function is formulated to systematically coordinate voltage tracking precision and power loss minimization. Third, the DNS-MPC strategy is developed to simultaneously achieve precise output voltage regulation, high efficiency, and ZVS operation over a wide load range without auxiliary circuits. Experimental validation under multiple operating points (80/100/120 V references) demonstrates consistent performance: the maximum voltage fluctuation is limited to 0.26 V, peak efficiency reaches 93.92%, and efficiency variation remains within 4.22% and ensures ZVS operation. Additional tests under coil misalignment confirm robust operation with efficiency above 89%, and detailed loss analysis shows that system losses were reduced by 29.1%, 25.22%, and 38.99% at load resistances of 20, 50, and 100 Ω, respectively.
- 13 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 6939-6950
Multiobjective Optimization With Minimum Output Error and Maximum Efficiency for WPT Systems Based on Discrete Neighborhood Search–Model Predictive Control Scheme
Traditional control schemes for wireless power transfer (WPT) systems struggle to achieve zero voltage switching (ZVS), output stability, and efficiency optimization simultaneously. To address this limitation, this article proposes a discrete neighborhood search–model predictive control (DNS-MPC) strategy for multiobjective optimization in inductor-capacitor-capacitor-series (LCC-S) compensated WPT systems, addressing three critical requirements: output regulations, transmission efficiency maximization, and ZVS realization. First, a mathematical model of the WPT system is developed based on circuit analysis. The derived expressions are then used to identify the operating regions that ensure ZVS across all power switches. Second, a composite cost function is formulated to systematically coordinate voltage tracking precision and power loss minimization. Third, the DNS-MPC strategy is developed to simultaneously achieve precise output voltage regulation, high efficiency, and ZVS operation over a wide load range without auxiliary circuits. Experimental validation under multiple operating points (80/100/120 V references) demonstrates consistent performance: the maximum voltage fluctuation is limited to 0.26 V, peak efficiency reaches 93.92%, and efficiency variation remains within 4.22% and ensures ZVS operation. Additional tests under coil misalignment confirm robust operation with efficiency above 89%, and detailed loss analysis shows that system losses were reduced by 29.1%, 25.22%, and 38.99% at load resistances of 20, 50, and 100 Ω, respectively.
- 26 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 1515-1519
Hierarchical-Constraint Model Predictive Control for Multiobjective Optimization of WPT System
Existing control methods for wireless power transfer (WPT) systems struggle to achieve zero-voltage switching (ZVS), output stability, and efficiency optimization at the same time. To address this problem, this letter proposes a hierarchical-constraint model predictive control (HCMPC) method by structuring the control into prioritized layers. HCMPC can achieve ZVS, output regulation, and efficiency optimization simultaneously without using complex weighting factors. Experimental results illustrate that HCMPC delivers an output voltage error below 0.5% and efficiency above 90% over a wide load range from 30 to 80 Ω. Under load transients, the settling times are 12 and 15 ms, respectively. Meanwhile, the WPT system can ensure ZVS for all switches in the whole load range. The proposed approach provides a robust and scalable solution for WPT systems, broadening their practical deployment in electric vehicles and consumer electronics products.
- 26 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 1515-1519
Hierarchical-Constraint Model Predictive Control for Multiobjective Optimization of WPT System
Existing control methods for wireless power transfer (WPT) systems struggle to achieve zero-voltage switching (ZVS), output stability, and efficiency optimization at the same time. To address this problem, this letter proposes a hierarchical-constraint model predictive control (HCMPC) method by structuring the control into prioritized layers. HCMPC can achieve ZVS, output regulation, and efficiency optimization simultaneously without using complex weighting factors. Experimental results illustrate that HCMPC delivers an output voltage error below 0.5% and efficiency above 90% over a wide load range from 30 to 80 Ω. Under load transients, the settling times are 12 and 15 ms, respectively. Meanwhile, the WPT system can ensure ZVS for all switches in the whole load range. The proposed approach provides a robust and scalable solution for WPT systems, broadening their practical deployment in electric vehicles and consumer electronics products.
- 22 May 2025
- Published by Springer Nature
- p. 248-257
Computer-Aided Accurate Modeling for S-S Bidirectional-Inductive-Power-Transfer Converters
- 22 May 2025
- Published by Springer Nature
- p. 248-257
Computer-Aided Accurate Modeling for S-S Bidirectional-Inductive-Power-Transfer Converters
- 20 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (4) , 4221-4229
Accurate Modeling of Discontinuous Operating State for LCC–LCC Compensated Inductive-Power-Transfer Converters by Time-Domain Analysis
The LCC-LCC compensation topology has been widely applied to inductive-power-transfer (IPT) systems to achieve constant-current (CC) output for battery charging. However, the mathematical model for the CC output is usually derived by fundamental-harmonic-analysis (FHA) applied in the frequency domain, which cannot describe the output current accurately when the load resistance is larger than a threshold value, i.e., R L >πω Lfs /2, because of the discontinuous part-sine current flowing into the rectifier. To tackle this problem, in this paper, an accurate time-domain-analysis (TDA) is firstly proposed to derive the mathematical model of output current for the LCC-LCC compensated IPT system. The derived output model shows that the output current would decrease with the increase of load resistance which is totally different from the conclusion from FHA. Both simulation and experimental results are presented to validate the accuracy of our derived output current model by TDA, which are consistent with our theoretical results. The proposed method can provide guidance on how to design the parameters of LCC-LCC compensated IPT converters to achieve rated outputs with small tolerance error for battery charging.
- 20 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (4) , 4221-4229
Accurate Modeling of Discontinuous Operating State for LCC–LCC Compensated Inductive-Power-Transfer Converters by Time-Domain Analysis
The LCC-LCC compensation topology has been widely applied to inductive-power-transfer (IPT) systems to achieve constant-current (CC) output for battery charging. However, the mathematical model for the CC output is usually derived by fundamental-harmonic-analysis (FHA) applied in the frequency domain, which cannot describe the output current accurately when the load resistance is larger than a threshold value, i.e., R L >πω Lfs /2, because of the discontinuous part-sine current flowing into the rectifier. To tackle this problem, in this paper, an accurate time-domain-analysis (TDA) is firstly proposed to derive the mathematical model of output current for the LCC-LCC compensated IPT system. The derived output model shows that the output current would decrease with the increase of load resistance which is totally different from the conclusion from FHA. Both simulation and experimental results are presented to validate the accuracy of our derived output current model by TDA, which are consistent with our theoretical results. The proposed method can provide guidance on how to design the parameters of LCC-LCC compensated IPT converters to achieve rated outputs with small tolerance error for battery charging.