VGVidisha Ganesh

Vidisha Ganesh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vidisha Ganesh has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Lyapunov-Based Nonlinear Model Predictive Control of Input-Delayed Functional Electrical Stimulation: Investigative Simulations and Experiments

    by Krysten Lambeth, Ziyue Sun, Ashwin Iyer, Vidisha Ganesh, Nitin Sharma

    Existing closed-loop controllers for functional electrical stimulation are prone to exceeding subject-specific stimulation limits, thereby limiting performance and also accelerating stimulation-induced muscle fatigue. In view of these challenges, this paper develops a Lyapunov-based model predictive control method to control knee flexion and extension during input-delayed stimulation. The method incorporates a contractive constraint under an electromechanical delay (EMD) compensation control law that achieves system stability despite an unknown constant input delay, bounded control constraints, and imperfectly estimated model parameters. A Lyapunov stability analysis proves that the Lyapunov constraint renders the closed-loop error ultimately bounded, and gain conditions are provided to guarantee recursive feasibility. LMPC's performance is explored in simulation and experiments and compared against an analytical proportional derivative-dynamic surface controller (PD-DSC) and a proportional-derivative-delay compensation (PD-DC) controller. In simulation, LMPC improved tracking root-mean-square error by 75.57% and 71.71%, on average, compared to PD-DSC and PD-DC, respectively. We observed that incorporating a slackening term often improved LMPC's tracking performance, although strict enforcement of the Lyapunov constraint was superior when there was greater EMD estimation error. Additionally, unlike PD-DSC and PD-DC, LMPC was not destabilized when EMD was overestimated or underestimated, nor did it violate input constraints. In knee extension experiments, LMPC respected input constraints, which PD-DSC did not. The LMPC was also validated in overground walking experiments to test its ability to produce both knee flexion and extension in participants with and without spinal cord injury.

  • Wearable Ultrasound Sensing With Dual Arrays and Machine Learning for Real-Time Tremor Characterization and Antagonist Muscle Monitoring

    by Xiangming Xue, Sunho Moon, Vidisha Ganesh, Qianqian Cai, Yu Chu, Ella Schropp, Daniel Roque, Tanya P. Garcia, Nitin Sharma, Xiaoning Jiang

    Precise and time-efficient sensing of tremor dynamics is essential for developing personalized, adaptive stimulation strategies for movement disorders such as Parkinson’s Disease (PD) and Essential Tremor (ET). Existing modalities—such as inertial measurement units (IMUs) and surface electromyography (EMG)—lack muscle specificity and are prone to stimulation artifacts. To address these limitations, we fabricated and applied a Wearable Ultrasound Sensing (WUS) system, featuring dual flexible 64- element transducer arrays with center frequency of 6 MHz conformed over the flexor carpi radialis (FCR) and extensor carpi radialis (ECR) muscles for simultaneous antagonist muscle monitoring. A machine learning (ML) pipeline was introduced to estimate tissue displacement (TD) from raw ultrasound signals. Across three participants and multiple trials, the WUS system achieved tremor frequency detection within 10 %variation relative to commercial B-mode and IMU sensors, and met statistical equivalence thresholds based on two one-sided test (TOST) analysis. The TD estimation models demonstrated high predictive accuracy, with overall Pearson correlation coefficients between predicted and actual values ranging from 0.88 to 0.97, normalized RMSE values below 10 %, and offline model building times under 800 seconds. Compared to classical B-mode speckle tracking, the proposed WUS-ML pipeline reduced offline model building time by 75 % (from 3095 sec to 792 sec). In real-time performance tests, it reduced frame-level latency from 3700 ms to 17 ms and achieved effective processing rates exceeding 50 Hz, well above the Nyquist threshold for tremor analysis. These results demonstrate the feasibility of dual-array wearable ultrasound for accurate, low-latency tremor tracking and lay the groundwork for future closed-loop afferent stimulation systems in both clinical and at-home environments.


  • Open Access

    Ultrasound-Informed State Estimation of Wrist Tremor Dynamics via Koopman Operator for Personalized Sensory Peripheral Nerve Stimulation

    by Xiangming Xue, Vidisha Ganesh, Daniel Roque, Tanya P. Garcia, Xiaoning Jiang, Nitin Sharma

    Tremor is among the most disabling motor symptoms in Parkinson's disease and essential tremor, yet current pharmacological and surgical therapies remain limited by side effects, invasiveness, and inconsistent efficacy. Sensory peripheral nerve stimulation (sPNS) has emerged as a non-invasive alternative, but its optimization requires computational models that integrate ultrasound-informed state estimation of tremor dynamics and adapt to individual variability. Here, we introduce a data-driven modeling framework that leverages ultrasound sensing within a Koopman operator approach for state estimation to capture wrist tremor dynamics. In a study of six individuals with Parkinsonian or essential tremor, ultrasound-informed models significantly improved accuracy, reducing time-domain prediction error from 38.1% to 21.3% and enhancing frequency-domain measures, including tremor frequency and power ratio. Modal input analysis revealed that ultrasound-derived features from flexor and extensor muscles accounted for >60% of model sensitivity, while intermuscular latency among sPNS parameters contributed most strongly (31.6%), consistent with the physiological principle of out-of-phase stimulation. The framework also proved resilient to sensor dropout, preserving dominant tremor frequency and temporal features via data-driven interpolation. In a pilot human-validation study involving one Parkinsonian tremor participant and one essential tremor participant, the model-informed protocols selected by the proposed framework produced the strongest suppression among the tested stimulation conditions, achieving mean suppression ratios of 28.3% and 45.1%, respectively. These findings establish ultrasound-informed modeling as a novel state-estimation and modeling strategy for tremor characterization, while also providing initial prospective support for model-guided personalization of sPNS parameters.

  • Ultrasound-Enhanced Data-Driven Modeling for Characterizing Natural Wrist Tremor Dynamics

    by Xiangming Xue, Vidisha Ganesh, Ashwin Iyer, Daniel Roque, Xiaoning Jiang, Nitin Sharma

    The complex interplay of neural and muscular activity underlying involuntary rhythmic wrist tremors poses significant challenges for effective symptom management, particularly with identifying key tremor characteristics such as dominant frequency and amplitude. This study introduces an ultrasound (US)-enhanced data-driven modeling framework that uses wrist angle kinematics as state variables which are augmented with muscle-specific ultrasound data inputs. We explore three modeling configurations: a wrist kinematics-only baseline model, a fixed-parameter US-augmented model, and a real-time adaptive US-enhanced model updated using a recursive least squares (RLS) algorithm. Comprehensive validation using time- and frequency-domain analyses was conducted using experimental data from six patients with tremor. Results show that integrating US input improves modeling specificity and accuracy by capturing internal muscle dynamics and temporal evolution patterns that are not accessible through IMU alone. Specifically, the modeling error in the time domain (nRMSE) decreased substantially from 49.36% in the baseline model to 24.53% in the US-augmented model. The adaptive model further reduced the error to just 0.48%, demonstrating its ability to dynamically account for the variability of tremor behaviors. Moreover, this work introduces, for the first time in tremor research, a comprehensive eigenvalue analysis of the data-driven model to extract clinically relevant tremor characteristics. The method enables accurate estimation of dominant tremor frequencies (average across patients nRMSE = 12.7%), quantification of dominant state contributions (mean $\Delta _{\text{dominance}}$ = 18.73%), and reliable tremor event detection (F1-score = 0.796). These findings highlight the framework's ability to not only reproduce tremor trajectories but also uncover how tremor behavior evolves over time in response to underlying neuromuscular activity. This work establishes a foundation for real-time tremor tracking and model-based control strategies, such as closed-loop afferent stimulation. By leveraging the unique sensing capabilities of ultrasound, the proposed framework offers a promising path toward personalized tremor modeling and intervention.


  • Open Access

    Enhancing Hybrid Exoskeleton Performance With Spatially Distributed Asynchronous Stimulation and Ultrasound Imaging-Based Fatigue Measurements

    by Ashwin Iyer, Vidisha Ganesh, Mayank Singh, William Filer, Christine Cleveland, Nitin Sharma

    This paper introduces an innovative approach, Spatially distributed asynchronous stimulation (SDAS), designed to enhance the fatigue resistance of electrically stimulated muscles for mobility assistance in individuals with spinal cord injury (SCI), stroke, and multiple sclerosis. The study focuses on modulating stimulation intensity in multiple distributed electrodes through a phenomenological model of SDAS to increase muscle power output. A model predictive control (MPC) approach is used to design optimal SDAS intensity profiles for knee extension tracking. The study also establishes a strong correlation between Ultrasound (US)-derived strain measurements of the quadriceps muscle and the model’s fatigue parameter. The model is extended to predict non-isometric knee extension and integrated with US-derived feedback from the quadriceps muscle to control stepping with the hybrid exoskeleton. The results demonstrate that the optimized SDAS inputs and US-derived fatigue measurements of spatially separated muscle regions during SDAS can effectively delay fatigue and increase muscle power output. This study underscores the importance of a model-based closed-loop SDAS approach and the integration of US-derived feedback in the design of a novel fatigue-resistant SDAS-based gait assistance technology.