Yunuen Reyes-Paz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yunuen Reyes-Paz has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Lilia Castillo-Martínez
Department of Clinical Nutrition, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
4 shared publications - José Luis Villanueva-Juárez
Clinical Nutrition Service, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán
2 shared publications - María Fernanda Bernal-Ceballos
Unidad de Atención a la Salud, Servicios Públicos de Salud del Instituto Mexicano del Seguro Social para el Bienestar, Mexico
2 shared publications - Thierry Hernández-Gilsoul
Emergency Department, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City 14080, Mexico
2 shared publications
Latest Publications
- 14 February 2026
- Published by MyJove Corporation
- No. 228,p. e69691
JoVE Video Dataset
Body composition assessment is crucial in clinical nutrition practice for screening, diagnosis, treatment, and prognosis of patients. Bioelectrical impedance analysis (BIA) is widely used to assess body composition. Impedance devices measure the body's electrical response (resistance) when exposed to an electrical current, thereby indirectly estimating body composition by conducting a low electrical current into the body. However, multiple factors, including devices, equations, indices, and population references, affect the interpretation of BIA results. Bioelectrical impedance vector analysis (BIVA) has been developed as an alternative method for semi-quantitative assessment of hydration status, which overcomes some limitations of traditional BIA by analyzing vector distance patterns and their distribution on resistance and reactance (R-Xc). This review describes the BIA device classification, which is useful for determining when the BIVA approach is appropriate for body composition analysis. This narrative review outlines the requirements and medical and nutritional uses of bioelectrical impedance vector analysis in adult patients over the past decade. Several publications have reported the clinical applications of BIVA in adult patients, including the evaluation of fluid volume status, control of body fluids, and prediction of negative outcomes in patients undergoing renal replacement therapy or admitted to critical care units. It has also been used as an alternative diagnostic tool in adults with fluid abnormalities to detect sarcopenia, cachexia, or malnutrition, reflecting low body cell mass or a decrease in soft tissue. However, some implications must be considered to avoid affecting the interpretation of the results, including differences in devices, analysis methods, and specific population references. Thus, this review aims to describe the differences between the devices and analysis techniques used for BIVA, which will be discussed in this review.
- 14 February 2026
- Published by MyJove Corporation
- No. 228,p. e69691
JoVE Video Dataset
Body composition assessment is crucial in clinical nutrition practice for screening, diagnosis, treatment, and prognosis of patients. Bioelectrical impedance analysis (BIA) is widely used to assess body composition. Impedance devices measure the body's electrical response (resistance) when exposed to an electrical current, thereby indirectly estimating body composition by conducting a low electrical current into the body. However, multiple factors, including devices, equations, indices, and population references, affect the interpretation of BIA results. Bioelectrical impedance vector analysis (BIVA) has been developed as an alternative method for semi-quantitative assessment of hydration status, which overcomes some limitations of traditional BIA by analyzing vector distance patterns and their distribution on resistance and reactance (R-Xc). This review describes the BIA device classification, which is useful for determining when the BIVA approach is appropriate for body composition analysis. This narrative review outlines the requirements and medical and nutritional uses of bioelectrical impedance vector analysis in adult patients over the past decade. Several publications have reported the clinical applications of BIVA in adult patients, including the evaluation of fluid volume status, control of body fluids, and prediction of negative outcomes in patients undergoing renal replacement therapy or admitted to critical care units. It has also been used as an alternative diagnostic tool in adults with fluid abnormalities to detect sarcopenia, cachexia, or malnutrition, reflecting low body cell mass or a decrease in soft tissue. However, some implications must be considered to avoid affecting the interpretation of the results, including differences in devices, analysis methods, and specific population references. Thus, this review aims to describe the differences between the devices and analysis techniques used for BIVA, which will be discussed in this review.
- 13 February 2026
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 228,p. e69691
Bioelectrical Impedance Vector Analysis in Adult Patients: Applications in Clinical Practice
Body composition assessment is crucial in clinical nutrition practice for screening, diagnosis, treatment, and prognosis of patients. Bioelectrical impedance analysis (BIA) is widely used to assess body composition. Impedance devices measure the body's electrical response (resistance) when exposed to an electrical current, thereby indirectly estimating body composition by conducting a low electrical current into the body. However, multiple factors, including devices, equations, indices, and population references, affect the interpretation of BIA results. Bioelectrical impedance vector analysis (BIVA) has been developed as an alternative method for semi-quantitative assessment of hydration status, which overcomes some limitations of traditional BIA by analyzing vector distance patterns and their distribution on resistance and reactance (R-Xc). This review describes the BIA device classification, which is useful for determining when the BIVA approach is appropriate for body composition analysis. This narrative review outlines the requirements and medical and nutritional uses of bioelectrical impedance vector analysis in adult patients over the past decade. Several publications have reported the clinical applications of BIVA in adult patients, including the evaluation of fluid volume status, control of body fluids, and prediction of negative outcomes in patients undergoing renal replacement therapy or admitted to critical care units. It has also been used as an alternative diagnostic tool in adults with fluid abnormalities to detect sarcopenia, cachexia, or malnutrition, reflecting low body cell mass or a decrease in soft tissue. However, some implications must be considered to avoid affecting the interpretation of the results, including differences in devices, analysis methods, and specific population references. Thus, this review aims to describe the differences between the devices and analysis techniques used for BIVA, which will be discussed in this review.
- 13 February 2026
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 228,p. e69691
Bioelectrical Impedance Vector Analysis in Adult Patients: Applications in Clinical Practice
Body composition assessment is crucial in clinical nutrition practice for screening, diagnosis, treatment, and prognosis of patients. Bioelectrical impedance analysis (BIA) is widely used to assess body composition. Impedance devices measure the body's electrical response (resistance) when exposed to an electrical current, thereby indirectly estimating body composition by conducting a low electrical current into the body. However, multiple factors, including devices, equations, indices, and population references, affect the interpretation of BIA results. Bioelectrical impedance vector analysis (BIVA) has been developed as an alternative method for semi-quantitative assessment of hydration status, which overcomes some limitations of traditional BIA by analyzing vector distance patterns and their distribution on resistance and reactance (R-Xc). This review describes the BIA device classification, which is useful for determining when the BIVA approach is appropriate for body composition analysis. This narrative review outlines the requirements and medical and nutritional uses of bioelectrical impedance vector analysis in adult patients over the past decade. Several publications have reported the clinical applications of BIVA in adult patients, including the evaluation of fluid volume status, control of body fluids, and prediction of negative outcomes in patients undergoing renal replacement therapy or admitted to critical care units. It has also been used as an alternative diagnostic tool in adults with fluid abnormalities to detect sarcopenia, cachexia, or malnutrition, reflecting low body cell mass or a decrease in soft tissue. However, some implications must be considered to avoid affecting the interpretation of the results, including differences in devices, analysis methods, and specific population references. Thus, this review aims to describe the differences between the devices and analysis techniques used for BIVA, which will be discussed in this review.
- 10 June 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 220,p. e68203
Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Acute heart failure is the most common cause of hospital admission in patients aged > 65 years, with congestion being the predominant symptom. It is widely known that congestion is the main cause of readmission and its association with poor outcomes. This study aimed to determine the cutoff value of the phase angle using bioelectrical impedance analysis in the first 24 h after admission for the prediction of in-hospital mortality and all-cause mortality or rehospitalization 90 day post discharge in patients with acute heart failure. The dataset analyzed for this protocol included 219 patients who presented to the emergency department with acute heart failure, of whom 115 died during hospitalization, 90 days post discharge, or were readmitted during the same period. Through univariable analysis using Cox proportional hazards regression analysis, potential predictors were identified, and a multivariable Cox proportional hazard model was used to identify the significant prognostic factors associated with patient survival and to control for confounding variables. Analysis of the phase angle adjusted by different predictors using restricted cubic splines revealed that lower values were directly associated with the risk of 90 day readmission or death post discharge, particularly when the cutoff value of PhA was <4.0°. All developed models showed moderate discriminatory ability (C-statistic < 0.80); however, the in-hospital mortality model demonstrated the highest discrimination ability (C-statistic, 0.75).
- 10 June 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 220,p. e68203
Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Acute heart failure is the most common cause of hospital admission in patients aged > 65 years, with congestion being the predominant symptom. It is widely known that congestion is the main cause of readmission and its association with poor outcomes. This study aimed to determine the cutoff value of the phase angle using bioelectrical impedance analysis in the first 24 h after admission for the prediction of in-hospital mortality and all-cause mortality or rehospitalization 90 day post discharge in patients with acute heart failure. The dataset analyzed for this protocol included 219 patients who presented to the emergency department with acute heart failure, of whom 115 died during hospitalization, 90 days post discharge, or were readmitted during the same period. Through univariable analysis using Cox proportional hazards regression analysis, potential predictors were identified, and a multivariable Cox proportional hazard model was used to identify the significant prognostic factors associated with patient survival and to control for confounding variables. Analysis of the phase angle adjusted by different predictors using restricted cubic splines revealed that lower values were directly associated with the risk of 90 day readmission or death post discharge, particularly when the cutoff value of PhA was <4.0°. All developed models showed moderate discriminatory ability (C-statistic < 0.80); however, the in-hospital mortality model demonstrated the highest discrimination ability (C-statistic, 0.75).
- 10 June 2025
- Published by MyJove Corporation
- No. 220,p. e68203
JoVE Video Dataset
Acute heart failure is the most common cause of hospital admission in patients aged > 65 years, with congestion being the predominant symptom. It is widely known that congestion is the main cause of readmission and its association with poor outcomes. This study aimed to determine the cutoff value of the phase angle using bioelectrical impedance analysis in the first 24 h after admission for the prediction of in-hospital mortality and all-cause mortality or rehospitalization 90 day post discharge in patients with acute heart failure. The dataset analyzed for this protocol included 219 patients who presented to the emergency department with acute heart failure, of whom 115 died during hospitalization, 90 days post discharge, or were readmitted during the same period. Through univariable analysis using Cox proportional hazards regression analysis, potential predictors were identified, and a multivariable Cox proportional hazard model was used to identify the significant prognostic factors associated with patient survival and to control for confounding variables. Analysis of the phase angle adjusted by different predictors using restricted cubic splines revealed that lower values were directly associated with the risk of 90 day readmission or death post discharge, particularly when the cutoff value of PhA was <4.0°. All developed models showed moderate discriminatory ability (C-statistic < 0.80); however, the in-hospital mortality model demonstrated the highest discrimination ability (C-statistic, 0.75).
- 10 June 2025
- Published by MyJove Corporation
- No. 220,p. e68203
JoVE Video Dataset
Acute heart failure is the most common cause of hospital admission in patients aged > 65 years, with congestion being the predominant symptom. It is widely known that congestion is the main cause of readmission and its association with poor outcomes. This study aimed to determine the cutoff value of the phase angle using bioelectrical impedance analysis in the first 24 h after admission for the prediction of in-hospital mortality and all-cause mortality or rehospitalization 90 day post discharge in patients with acute heart failure. The dataset analyzed for this protocol included 219 patients who presented to the emergency department with acute heart failure, of whom 115 died during hospitalization, 90 days post discharge, or were readmitted during the same period. Through univariable analysis using Cox proportional hazards regression analysis, potential predictors were identified, and a multivariable Cox proportional hazard model was used to identify the significant prognostic factors associated with patient survival and to control for confounding variables. Analysis of the phase angle adjusted by different predictors using restricted cubic splines revealed that lower values were directly associated with the risk of 90 day readmission or death post discharge, particularly when the cutoff value of PhA was <4.0°. All developed models showed moderate discriminatory ability (C-statistic < 0.80); however, the in-hospital mortality model demonstrated the highest discrimination ability (C-statistic, 0.75).