Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ju-Hyeon Park has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reframing urban green infrastructure for particulate matter mitigation: a systematic review and functional planning framework for high-density cities

    by Jeong-Hee Eum, Jeong-Min Son, Ju-Hyeon Park, Uk-Je Sung, Ju-Eun Kim, Alex Guenther, Jung-Hun Woo

    Rapid urbanization and increasing particulate matter (PM) pollution have heightened public health risks in high-density urban environments, highlighting the need for effective nature-based solutions. Although urban green infrastructure (UGI) is widely recognized for its potential to improve air quality, existing classification systems, particularly those based on development purposes, remain inadequate for capturing the functional mechanisms necessary for effective PM mitigation. This limitation hinders the development of context-sensitive planning strategies that account for spatial conditions, emission sources, and human exposure. To address this gap, this study develops a PM-oriented functional planning framework for high-density cities by reclassifying UGI according to PM mitigation functions rather than conventional purpose-based categories. Drawing on 8 Korean institutional/policy documents and a systematic review of 139 academic studies (124 international and 15 Korean), four functional classification criteria, namely development purpose, proximity to emission sources, receptor vulnerability, and physical structure, were identified and used to establish an evidence-informed typology comprising ten PM-oriented UGI types. These types were contextualized and operationalized within the Korean urban system as a representative model for complex, high-density urban development. The findings indicate that type-specific strategies emphasizing deposition, blocking, and dispersion are essential for effective PM mitigation. Structurally diverse vegetation can enhance particle deposition in residential areas, whereas optimized vegetation porosity improves performance in roadside environments. The proposed framework offers a decision-support tool for policymakers and urban planners; however, further empirical validation is required to assess its effectiveness and applicability across diverse urban contexts.

  • Open Access

    Designing Climate-Adaptive Street Greenery for Pedestrian Thermal Environment: A Spatial Framework Linking Sidewalk Width, Street Orientation, and Street Tree Configuration from a Korean Case Study

    by Ju-Hyeon Park, Jeong-Hee Eum, Jeong-Min Son, Uk-Je Sung

    Under the growing threat of urban heat stress, street canyons play a critical role in shaping the pedestrian thermal environment. While street greenery is an effective mitigation strategy, its performance varies substantially with physical characteristics—such as aspect ratio, street width, and sidewalk width—highlighting the need for spatially adaptive design. This study evaluates the effects of sidewalk width, street orientation, and planting structure on thermal conditions in a humid subtropical climate in Daegu Metropolitan City, Republic of Korea. The analysis focuses on open low-aspect-ratio street canyons (H/W = 0.86 for E–W and 0.43 for N–S orientations). Using a validated ENVI-met (Version 5.6.1) model based on field measurements from Daegu, Republic of Korea, 56 street-greening scenarios were simulated by systematically varying sidewalk width, street orientation, planting rows, spacing, and planting structure. Results show that multi-row planting served as the primary structural framework governing thermal performance. Optimal configurations varied with sidewalk width, with two-row planting for 6 m sidewalks and three-row planting for 10 m sidewalks providing the most effective cooling. The greatest cooling (−2.02 °C) was achieved when optimized multi-row configurations were combined with multi-layer planting. Once optimal multi-row configurations were established, the presence of understory vegetation had a greater influence on thermal improvement than its specific composition, allowing flexibility in understory design. Clear spatial asymmetries were identified, with the highest thermal stress occurring on the north-side sidewalk in E–W streets and the west-side sidewalk in N–S streets. Targeted planting in these locations produced greater cooling benefits than uniform strategies. These findings provide a spatially grounded framework for climate-responsive street greenery and offer practical design guidance, highlighting the need for context-specific, optimized multi-row planting strategies adapted to local urban and climatic conditions.


  • Open Access

    Development of a planting model for creating street green spaces to improve the urban thermal environment

    by Juhyeon Park, Jeong-Hee Eum

    Cities around the world are working to increase canopy coverage within cities to 30%~ 40% for improving the urban thermal environment. This study developed an efficient and systematic roadside green space planting model aimed at improving the urban thermal environment, focusing on street canyons with low aspect ratios and high thermal stress. The criteria for multi-row planting and installation of vegetative median strips were established based on the width of the sidewalk and road. For street trees with a crown width of 8m, two-row planting showed the highest cooling effect for a sidewalk width of 6m, and three-row planting was identified as the most effective strategy for enhancing the thermal environment along sidewalks with a width of 10m. Additionally, it was shown that the installation of vegetated median strips was effective for roads with four or more lanes. These results are equally applicable to both east-west and north-south oriented street canyons.Furthermore, solutions for the optimized planting method of multi-row planting and vegetated median strips were also presented. The spacing between street trees should be the same as or narrower than the crown width, and the width of the green strap should be as wide as possible to enhance the cooling effect. The multi-layer structural planting demonstrates that the structure of trees + subtrees + shrubs is the most effective for improving the thermal environment in both multi-row planting and vegetated median strips.This study is expected that urban planners, designers, and other professionals who plan and design urban spaces will be able to increase the possibility of alleviating urban thermal environment problems by understanding the thermal environment improvement mechanism through green space creation and utilizing it in green space planning and design.