Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Julian Nwodo has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Water Quality Dynamics in the Mohokare Local Municipality: A Focus on the Rouxville Rural Community

    by Karabo Joseph Maqeba, Leana Esterhuizen, Julian Nwodo, Irene Mokgadi

    The study evaluated the drinking water quality of Rouxville (RX) in Mohokare Local Municipality in the Free State, using chemical, physical, and microbiological parameters in comparison with South African National Standard 241 (SANS 241:2015). Drinking water samples were collected monthly from five sample sites, including the water treatment plant (WTP) and four end-user points, over a period of three years (2021–2023). Microbiological parameters revealed persistent non-compliance, with total coliforms and Escherichia coli (E. coli) frequently exceeding recommended limits by SANS 241 at multiple sites. The highest total coliform concentration of 201 CFU was recorded at the Rouxville Water Treatment Plant during the third year (2023) of sampling, while E. coli reached a maximum of 11 CFU at an end-user point, indicating the presence of possible pathogens in the water system. Colour exceeded the recommended limit (15 Pt-Co mg/L) at all sampling sites, with the highest value of 133 Pt-Co mg/L recorded at Rolelethunya Library. Chemical parameters mostly complied with SANS 241 limits, elevated values of total alkalinity and aluminium were observed at certain sites, particularly during the third year (2023) of sampling. The Canadian Council of Ministers of the Environment Water Quality Index (CCME-WQI) was also used to determine the overall water quality of the sample sites. The findings revealed that several sample sites had non-compliant parameters. The CCME-WQI revealed that the drinking water quality of Rouxville was either in the marginal or fair category, indicating that the water quality may be occasionally or frequently threatened, posing public health risks. These findings highlight the urgent need to ensure regular maintenance of WTP and ensuring continuous microbial monitoring.

  • Open Access

    Water Quality Dynamics in the Mohokare Local Municipality: A Focus on the Rouxville Rural Community

    by Karabo Joseph Maqeba, Leana Esterhuizen, Julian Nwodo, Irene Mokgadi

    The study evaluated the drinking water quality of Rouxville (RX) in Mohokare Local Municipality in the Free State, using chemical, physical, and microbiological parameters in comparison with South African National Standard 241 (SANS 241:2015). Drinking water samples were collected monthly from 5 sample sites, including the water treatment plant (WTP) and four end-user points, over a period of three years (2021–2023). Microbiological parameters revealed persistent non-compliance, with total coliforms and Escherichia coli (E. coli) frequently exceeding recommended limits by SANS 241 at multiple sites. The highest total coliform concentration of 201 CFU was recorded at the Rouxville Water Treatment Plant during the third year (2023) of sampling, while E. coli reached a maximum of 11 CFU at an end-user point, indicating the presence of possible pathogens in the water system. Colour exceeded the recommended limit (15 Pt-Co mg/L) at all sampling sites, with the highest value of 133 Pt-Co mg/L recorded at Rolelethunya Library. Chemical parameters mostly complied with SANS 241 limits, elevated values of total alkalinity and aluminium were observed at certain sites, particularly during the third year (2023) of sampling. The Canadian Council of Ministers of the Environment Water Quality Index (CCME-WQI) was also used to determine the overall water quality of the sample sites. The findings revealed that several sample sites had non-compliant parameters. The CCME-WQI revealed that the drinking water quality of Rouxville was either in the marginal or fair category, indicating that the water quality may be occasionally or frequently threatened, posing public health risks. These findings highlight the urgent need to ensure regular maintenance of WTP and ensuring continuous microbial monitoring.

  • Open Access

    Comparison of the Material Quality of AlxIn1−xN (x—0–0.50) Films Deposited on Si(100) and Si(111) at Low Temperature by Reactive RF Sputtering

    by Michael Sun, Rodrigo Blasco, Julian Nwodo, María de la Mata, Sergio I. Molina, Akhil Ajay, Eva Monroy, Sirona Valdueza-Felip, Fernando B. Naranjo

    AlxIn1−xN ternary semiconductors have attracted much interest for application in photovoltaic devices. Here, we compare the material quality of AlxIn1−xN layers deposited on Si with different crystallographic orientations, (100) and (111), via radio-frequency (RF) sputtering. To modulate their Al content, the Al RF power was varied from 0 to 225 W, whereas the In RF power and deposition temperature were fixed at 30 W and 300 °C, respectively. X-ray diffraction measurements reveal a c-axis-oriented wurtzite structure with no phase separation regardless of the Al content (x = 0–0.50), which increases with the Al power supply. The surface morphology of the AlxIn1−xN layers improves with increasing Al content (the root-mean-square roughness decreases from ≈12 to 2.5 nm), and it is similar for samples grown on both Si substrates. The amorphous layer (~2.5 nm thick) found at the interface with the substrates explains the weak influence of their orientation on the properties of the AlxIn1−xN films. Simultaneously grown AlxIn1−xN-on-sapphire samples point to a residual n-type carrier concentration in the 1020–1021 cm−3 range. The optical band gap energy of these layers evolves from 1.75 to 2.56 eV with the increase in the Al. PL measurements of AlxIn1−xN show a blue shift in the peak emission when adding the Al, as expected. We also observe an increase in the FWHM of the main peak and a decrease in the integrated emission with the Al content in room-temperature PL measurements. In general, the material quality of the AlxIn1-xN films on Si is similar for both crystallographic orientations.


  • Open Access

    Decoupling the Monitoring of Solar Water Heaters and their Usage Profiles

    by Julian C. Nwodo, Ochuko K. Overen, Edson L. Meyer

    South Africa is the most technologically advanced nation in Africa. However, the country is plagued with constant load shedding. The country receives about 2500 sunshine hours annually, with daily average irradiation levels of 4.5–6.5 kWh/m2. Despite these potentials, the use of electricity for domestic water heating is still prevalent in the country. The mass rollout of solar water heating (SWH) technologies in the low-cost housing sector across the country were met with massive failures. This study aims to assess the energy yield of a passive flat plate and an evacuated tube solar water heating system by evaluating the performance of these systems to address the energy crisis in South Africa. The flat plate (FP) and evacuated tube (ET) solar water heating systems were monitored for four days, characterised by varying sky conditions through instantaneous data measurement at 5 s. The parameters measured were water temperature, ambient temperature, irradiance at the plane of array, relative humidity, wind speed and direction. The results obtained show that a maximum irradiance of 1050 W/m2 was obtained on a clear day and corresponded to a hot water temperature of about 58 °C and 65 °C for the FP and ET, respectively. However, a cloudy day with a maximum irradiance of 400 W/m2 produced about 22 °C and 29 °C of hot water for the FP and ET, respectively. The results obtained in this study will guide stakeholders in the renewable energy sector towards employing SWH systems to replace or augment the electric geyser. Solar water heaters (SWH) can be used in the low-cost housing sector to provide hot water. Hence, the assessments in this study offer essential information for the deployment of these systems to reduce demand on the ailing South African electricity utility, Eskom, and mitigate climate change.


  • Open Access

    Autonomous Dynamic Adaptability System to Maintain Irradiance Levels in a Steady-State Solar Simulator

    by Edson L. Meyer, Julian C. Nwodo

    This paper presents the design of an autonomous dynamic adaptability system (ADAS) for maintaining the irradiance levels of a steady-state xenon arc lamp solar simulator (SS). The solar simulator is used to carry out indoor testing and accelerated age tests on photovoltaic (PV) cells at the Fort Hare Institute of Technology (FHIT). The ADAS was designed primarily for two reasons: Firstly, to maintain a set irradiance level, irrespective of external effects which may cause unintended irradiance drift or fluctuations, while carrying out indoor tests. Secondly, to achieve the solar simulator set point quicker, thus reducing temperature build up on the target area. At a cold start, the SS runs at 20% of its rated current (145 A). At 20% of 145 A, the simulator gave an irradiance of 145.97 Wm−2 with a non-uniformity of 1.02%, and a cell surface temperature of 24.9 °C. At 50%, the simulator produced irradiance of 501.30 Wm−2, with a non-uniformity of 1.53% and a cell surface temperature of 25.0 °C. The irradiance of 1000 Wm−2, with a non-uniformity of 3.26% and a cell surface temperature of 25.9 °C, was achieved at 90% of the rated current. From the results obtained, the ADAS demonstrates that it can reliably operate the SS with very minimal human–machine interaction. Through the autonomous dynamic adaptability, set irradiance levels are maintained in a steady-state solar simulator once the user supplies operational set points via the supervisory control and data acquisition (SCADA) interface.