Friderike K. Longarino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Friderike K. Longarino has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Cedric Beyer
Department of Radiation Oncology and Heidelberg Ion Beam Therapy Center (HIT), Heidelberg University Hospital, Heidelberg, Germany
2 shared publicationsJulia Bauer
Heidelberg University Hospital
2 shared publicationsJürgen Debus
Heidelberg University Hospital
2 shared publicationsKatharina Seidensaal
Department of Radiation Oncology and Heidelberg Ion Beam Therapy Center (HIT), Heidelberg University Hospital, Heidelberg, Germany
2 shared publicationsKathryn E. Keenan
National Institute of Standards and Technology, Boulder, USA
2 shared publications- Lars Wessel
Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
2 shared publications
Latest Publications
- Open Access
- 21 April 2026
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 25
Influence of Interfractional Variations of Bladder and Rectal Filling on Vaginal Cuff Movement and the Role of Rectal Balloons in Gynecological Pelvic Proton Beam Therapy
Introduction: Postoperative active raster-scanning intensity modulated proton beam therapy (IMPT) for gynecological cancers requires precise target coverage, yet interfractional motion of the vaginal cuff and adjacent pelvic organs may compromise dosimetric robustness. This study retrospectively assessed interfractional organ movement and evaluated the clinical need for rectal balloon (RB) use to ensure adequate target coverage. Methods: 23 patients, 17/6 with/without RB, received postoperative IMPT between 2017 and 2020 at Heidelberg Ion-beam Therapy Center (HIT). Positioning verification computed tomography (pv-CT) and treatment planning CT (tp-CT) images were retrieved and rectum, bladder and the vaginal cuff (VC) were contoured. The clinical target volume (CTV) and planning target volume (PTV) were mapped from tp-CT to the pv-CT images and forward dose calculation was performed. To assess the volume of the VC not covered by the CTV or PTV, the region of interest (ROI), VC outside of CTV (VC-CTV) and outside of PTV (VC-PTV) were created. Volume differences (Δ) to the tp-CT images and dose parameters for each ROI were evaluated. Results: 139 pv-CTs were analysed. The use of RB significantly reduced VC displacements, resulting in fewer pv-CTs with the VC located outside the CTV (40% vs. 91%, p = 0.0252) and PTV (28% vs. 68%, p = 0.0362). CTV/PTV coverage and ROI doses remained stable across all fractions and there was no significant difference between groups. The applied PTV margins ensured robust dose coverage despite interfractional anatomical variations. Conclusion: RB application effectively reduced interfractional VC motion and there was no significant Δ in target coverage or ROI doses. Using tp-CT images with full and empty bladder for definition of the CTV and standardized PTV margins contributed to stable dosimetry outcomes, confirming the robustness of the used IMPT treatment protocol. However, the use of RB may be beneficial, especially in patients with known gastrointestinal comorbidities or trapped air in the rectum.
- 21 April 2026
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 25
Open AccessInfluence of Interfractional Variations of Bladder and Rectal Filling on Vaginal Cuff Movement and the Role of Rectal Balloons in Gynecological Pelvic Proton Beam Therapy
Introduction: Postoperative active raster-scanning intensity modulated proton beam therapy (IMPT) for gynecological cancers requires precise target coverage, yet interfractional motion of the vaginal cuff and adjacent pelvic organs may compromise dosimetric robustness. This study retrospectively assessed interfractional organ movement and evaluated the clinical need for rectal balloon (RB) use to ensure adequate target coverage. Methods: 23 patients, 17/6 with/without RB, received postoperative IMPT between 2017 and 2020 at Heidelberg Ion-beam Therapy Center (HIT). Positioning verification computed tomography (pv-CT) and treatment planning CT (tp-CT) images were retrieved and rectum, bladder and the vaginal cuff (VC) were contoured. The clinical target volume (CTV) and planning target volume (PTV) were mapped from tp-CT to the pv-CT images and forward dose calculation was performed. To assess the volume of the VC not covered by the CTV or PTV, the region of interest (ROI), VC outside of CTV (VC-CTV) and outside of PTV (VC-PTV) were created. Volume differences (Δ) to the tp-CT images and dose parameters for each ROI were evaluated. Results: 139 pv-CTs were analysed. The use of RB significantly reduced VC displacements, resulting in fewer pv-CTs with the VC located outside the CTV (40% vs. 91%, p = 0.0252) and PTV (28% vs. 68%, p = 0.0362). CTV/PTV coverage and ROI doses remained stable across all fractions and there was no significant difference between groups. The applied PTV margins ensured robust dose coverage despite interfractional anatomical variations. Conclusion: RB application effectively reduced interfractional VC motion and there was no significant Δ in target coverage or ROI doses. Using tp-CT images with full and empty bladder for definition of the CTV and standardized PTV margins contributed to stable dosimetry outcomes, confirming the robustness of the used IMPT treatment protocol. However, the use of RB may be beneficial, especially in patients with known gastrointestinal comorbidities or trapped air in the rectum.
- 12 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2)
3D range modulators for fast, conformal carbon ion therapy: anthropomorphic phantom validation and robustness analysis
Objective: Fast and precise delivery of ion-beam therapy is essential for improving clinical throughput and intrafractional motion management, yet synchrotron-based systems require multiple energy layers for depth dose coverage, resulting in delays on the order of minutes. To eliminate energy layer switching times, a fast Monte Carlo (MC)-based workflow for patient-specific 3D range modulators (3D-RMs) was developed to enable monoenergetic, conformal carbon irradiation at clinically viable speeds. To mirror realistic clinical use, the dosimetric impact of setup and RM geometry deviations from simulated models were assessed. Approach: The workflow begins with spot extraction from clinical intensity modulated particle therapy (IMPT) plans, followed by RM geometry optimization, fast MC dose verification using MonteRay, and 3D printing final geometries. Experimental validations were performed for spread-out Bragg peaks (SOBPs) in water, and two targets in an anthropomorphic head phantom: 1) in a homogeneous brain region and 2) across a heterogeneous bone-soft tissue interface. Robustness against realistic setup and printing errors were assessed in the heterogeneous case. Main results: Each RM geometry was optimized in under one minute and the RM-based plans achieved dose distributions comparable to IMPT with similar target coverage and homogeneity. Simulated and measured depth dose profiles for SOBP plans agreed within 1.2% local deviation in the target. In the head phantom, measured 2D dose maps achieved local gamma pass rates >99% (2%/2 mm, 10% threshold) in both uniform and anatomically complex settings. Plans were robust to setup deviations up to 1 mm, and manufacturing deviations up to 100 µm. Significance: This rapid, clinically feasible workflow enables conformal, monoenergetic carbon ion delivery with dosimetric quality comparable to IMPT even in heterogenous scenarios. The substantially reduce treatment delivery time facilitates motion mitigation and higher patient throughput, and may also provide a technical basis for exploring FLASH regimes in synchrotron-based ion beam facilities.
- 12 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2)
3D range modulators for fast, conformal carbon ion therapy: anthropomorphic phantom validation and robustness analysis
Objective: Fast and precise delivery of ion-beam therapy is essential for improving clinical throughput and intrafractional motion management, yet synchrotron-based systems require multiple energy layers for depth dose coverage, resulting in delays on the order of minutes. To eliminate energy layer switching times, a fast Monte Carlo (MC)-based workflow for patient-specific 3D range modulators (3D-RMs) was developed to enable monoenergetic, conformal carbon irradiation at clinically viable speeds. To mirror realistic clinical use, the dosimetric impact of setup and RM geometry deviations from simulated models were assessed. Approach: The workflow begins with spot extraction from clinical intensity modulated particle therapy (IMPT) plans, followed by RM geometry optimization, fast MC dose verification using MonteRay, and 3D printing final geometries. Experimental validations were performed for spread-out Bragg peaks (SOBPs) in water, and two targets in an anthropomorphic head phantom: 1) in a homogeneous brain region and 2) across a heterogeneous bone-soft tissue interface. Robustness against realistic setup and printing errors were assessed in the heterogeneous case. Main results: Each RM geometry was optimized in under one minute and the RM-based plans achieved dose distributions comparable to IMPT with similar target coverage and homogeneity. Simulated and measured depth dose profiles for SOBP plans agreed within 1.2% local deviation in the target. In the head phantom, measured 2D dose maps achieved local gamma pass rates >99% (2%/2 mm, 10% threshold) in both uniform and anatomically complex settings. Plans were robust to setup deviations up to 1 mm, and manufacturing deviations up to 100 µm. Significance: This rapid, clinically feasible workflow enables conformal, monoenergetic carbon ion delivery with dosimetric quality comparable to IMPT even in heterogenous scenarios. The substantially reduce treatment delivery time facilitates motion mitigation and higher patient throughput, and may also provide a technical basis for exploring FLASH regimes in synchrotron-based ion beam facilities.
- Open Access
- 14 June 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 35
Stability of liver position in a shuttle-based workflow for daily online magnetic resonance imaging-guided particle therapy
- 14 June 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 35
Open AccessStability of liver position in a shuttle-based workflow for daily online magnetic resonance imaging-guided particle therapy
- Open Access
- 29 March 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 34, 100758
Ultra-low field magnetic resonance breast imaging in prone and seated positions for radiation therapy
- 29 March 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 34, 100758
Open AccessUltra-low field magnetic resonance breast imaging in prone and seated positions for radiation therapy
- Open Access
- 20 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (5) , 1750-1765
Breast Coil Optimization for Low Field MRI and Future MR-Guided Proton Therapy
Objective: Magnetic resonance imaging of the breast and the chest wall imaging was performed at ultra-low field (ULF) using optimal radiofrequency (RF) coil designs and, with an eye toward future application in MR-guided proton therapy (MRgPT), simulation studies of a pencil proton beam trajectory in low and ultra-low magnetic fields were performed. Methods: The primary focus in this study is the RF coil design, which is approached as a multi-objective optimization (MOO) problem and effectively solved using a Pareto optimality formalism. Our coil winding pattern algorithm simultaneously optimizes the magnetic field homogeneity of the coil, the attainable MRI signal-to-noise ratio (SNR), and the magnetic field drop-off into the chest wall for improved OAR imaging. Five transmit/receive single channel breast-shaped RF coils were constructed, and 3D phantom MRI was performed at 6.5 mT. The RF magnetic field homogeneity across the imaging volume and SNR were analyzed among the different coils. In vivo breast imaging was performed for the first time at 6.5 mT. Monte Carlo simulations were implemented to study the influence of copper wire on a proton beam, as well as the beam deflection at various static field strengths. Results: Our MOO method was validated - the observed field homogeneity, the relative ratio of attainable SNRs for all five breast coils, and the MRI signal from the chest agree with the simulations. In vivo breast and chest wall images acquired at ULF reveal good breast tissue contrast and can also visualize the heart. Finally, the results of this work indicate that a field strength of ∼50 mT with gradient strengths of ∼10 mT/m to minimize proton beam deflection, and the ability to achieve a ∼2 ´ 2 ´ 5 mm3 spatial resolution within few minutes are essential for making MRgPT clinically feasible. Conclusion: Our MOO method can be used to design breast coils that meet a wide range of imaging requirements.
- 20 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (5) , 1750-1765
Open AccessBreast Coil Optimization for Low Field MRI and Future MR-Guided Proton Therapy
Objective: Magnetic resonance imaging of the breast and the chest wall imaging was performed at ultra-low field (ULF) using optimal radiofrequency (RF) coil designs and, with an eye toward future application in MR-guided proton therapy (MRgPT), simulation studies of a pencil proton beam trajectory in low and ultra-low magnetic fields were performed. Methods: The primary focus in this study is the RF coil design, which is approached as a multi-objective optimization (MOO) problem and effectively solved using a Pareto optimality formalism. Our coil winding pattern algorithm simultaneously optimizes the magnetic field homogeneity of the coil, the attainable MRI signal-to-noise ratio (SNR), and the magnetic field drop-off into the chest wall for improved OAR imaging. Five transmit/receive single channel breast-shaped RF coils were constructed, and 3D phantom MRI was performed at 6.5 mT. The RF magnetic field homogeneity across the imaging volume and SNR were analyzed among the different coils. In vivo breast imaging was performed for the first time at 6.5 mT. Monte Carlo simulations were implemented to study the influence of copper wire on a proton beam, as well as the beam deflection at various static field strengths. Results: Our MOO method was validated - the observed field homogeneity, the relative ratio of attainable SNRs for all five breast coils, and the MRI signal from the chest agree with the simulations. In vivo breast and chest wall images acquired at ULF reveal good breast tissue contrast and can also visualize the heart. Finally, the results of this work indicate that a field strength of ∼50 mT with gradient strengths of ∼10 mT/m to minimize proton beam deflection, and the ability to achieve a ∼2 ´ 2 ´ 5 mm3 spatial resolution within few minutes are essential for making MRgPT clinically feasible. Conclusion: Our MOO method can be used to design breast coils that meet a wide range of imaging requirements.