Oleg V. Fedorov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Oleg V. Fedorov has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Alexey V. Kovalenko
Research Institute for Systems Biology and Medicine (RISBM), Moscow, Russia
4 shared publications - Grigory L. Kozhemyakin
Research Institute for Systems Biology and Medicine (RISBM), Moscow, Russia
4 shared publications - Nikita M. Baraboshkin
Research Institute for Systems Biology and Medicine (RISBM), Moscow, Russia
4 shared publications - Anastasia V. Vakaryuk
Research Institute for Systems Biology and Medicine (RISBM), Moscow, Russia
3 shared publications - Angelina A. Lebedeva
Research Institute for Systems Biology and Medicine (RISBM), Moscow, Russia
3 shared publications - Ivan Chudinov
Laboratory of Multiomics Research, Scientific Research Institute for Systems Biology and Medicine, Federal Service on Consumer Rights Protection and Human Well-Being Surveillance, Russia
3 shared publications
Latest Publications
- Open Access
Affordable 96-parallel SPPS: hardware and software add-on for automated liquid handling platforms
ParSynt-P is a hardware and software add-on that converts a liquid-handling robot already available in a proteomics laboratory (Tecan Freedom EVO) into a parallel plate-format peptide synthesizer for generating libraries of candidate peptide standards for targeted blood plasma proteomics. The manifold is milled from polytetrafluoroethylene and has ports for an inert gas and a vacuum line; a standard commercially available 96-well filtration plate is secured to it with an airtight seal. The software layer generates robot worklists from a table of peptide sequences and controls switching of the N₂/vacuum lines, including pulsed gas mixing. The system performs up to 96 syntheses per run, and coupling of one residue takes 94 min. Workability of this 96-well format was verified on three fully loaded plates. The uniformity of synthesis conversion across the plate was measured quantitatively using a characterized NAT/SIL standard pair. The add-on cost $351, while the synthesis cost is $0.23 per coupling and $1.14 per milligram of crude product, an order of magnitude below the market price of custom synthesis.
Open AccessAffordable 96-parallel SPPS: hardware and software add-on for automated liquid handling platforms
ParSynt-P is a hardware and software add-on that converts a liquid-handling robot already available in a proteomics laboratory (Tecan Freedom EVO) into a parallel plate-format peptide synthesizer for generating libraries of candidate peptide standards for targeted blood plasma proteomics. The manifold is milled from polytetrafluoroethylene and has ports for an inert gas and a vacuum line; a standard commercially available 96-well filtration plate is secured to it with an airtight seal. The software layer generates robot worklists from a table of peptide sequences and controls switching of the N₂/vacuum lines, including pulsed gas mixing. The system performs up to 96 syntheses per run, and coupling of one residue takes 94 min. Workability of this 96-well format was verified on three fully loaded plates. The uniformity of synthesis conversion across the plate was measured quantitatively using a characterized NAT/SIL standard pair. The add-on cost $351, while the synthesis cost is $0.23 per coupling and $1.14 per milligram of crude product, an order of magnitude below the market price of custom synthesis.
- Open Access
Direct empirical in-house assessment of peptide proteotypicity for targeted proteomics
In bottom-up proteomics peptide it was early shown that despite a certain protein is present in a sample, only a subset of it’s proteolytic peptide products will be detected with LC-MS analysis. Property of peptide being frequently detected given its source protein’s identification was called proteotypicity. Much effort has been since applied to predict proteotypic peptides and summarize evidence on peptide detection. Nevertheless, when targeted proteomics method is being developed, prediction or inference from communal experience might be inaccurate and prior knowledge of true peptide proteotypicity in a selected setup for a selected population is necessary. In this work we test fully in-house approach for proteotypicity assessment including comprehensive peptide synthesis and detection verification. Proteotypicity and contribution of sample processing and biology-related factors are estimated in a model experiment for three plasma proteins, albumin, ceruloplasmin and C-reactive protein.
Open AccessDirect empirical in-house assessment of peptide proteotypicity for targeted proteomics
In bottom-up proteomics peptide it was early shown that despite a certain protein is present in a sample, only a subset of it’s proteolytic peptide products will be detected with LC-MS analysis. Property of peptide being frequently detected given its source protein’s identification was called proteotypicity. Much effort has been since applied to predict proteotypic peptides and summarize evidence on peptide detection. Nevertheless, when targeted proteomics method is being developed, prediction or inference from communal experience might be inaccurate and prior knowledge of true peptide proteotypicity in a selected setup for a selected population is necessary. In this work we test fully in-house approach for proteotypicity assessment including comprehensive peptide synthesis and detection verification. Proteotypicity and contribution of sample processing and biology-related factors are estimated in a model experiment for three plasma proteins, albumin, ceruloplasmin and C-reactive protein.
- Open Access
Quality control of blood plasma for mass-spectrometry proteomic research
Mishandling of samples during blood plasma preparation may lead to biases in proteomic analysis and false interpretation of data. Previous plasma proteome profiling study ( Geyer, Mann et al ., 2019) described proteins that may serve to indicate poor plasma sample quality. We have established a targeted quantitative method for three prominent panels of markers proposed by previous study for exclusion of hemolyzed and coagulation samples. We conducted a model experiment similar to Geyer, Mann et al ., with both panoramic and targeted detection and investigated the feasibility of application internal control for hemolysis in targeted proteomic analysis by using incorrectly collected plasma. We propose to include plasma sample hemolysis assessment into standard MRM analysis and associated sample exclusion criteria.
Open AccessQuality control of blood plasma for mass-spectrometry proteomic research
Mishandling of samples during blood plasma preparation may lead to biases in proteomic analysis and false interpretation of data. Previous plasma proteome profiling study ( Geyer, Mann et al ., 2019) described proteins that may serve to indicate poor plasma sample quality. We have established a targeted quantitative method for three prominent panels of markers proposed by previous study for exclusion of hemolyzed and coagulation samples. We conducted a model experiment similar to Geyer, Mann et al ., with both panoramic and targeted detection and investigated the feasibility of application internal control for hemolysis in targeted proteomic analysis by using incorrectly collected plasma. We propose to include plasma sample hemolysis assessment into standard MRM analysis and associated sample exclusion criteria.
- Open Access
Automated Multiplex Plasma Proteomics for Quality Assessment and Clinical Triage: A Proof-of-Concept in Indeterminate Thyroid Nodules
Fine-needle aspiration biopsy of thyroid nodules frequently yields indeterminate results, leading to unnecessary diagnostic surgeries. We evaluated a targeted plasma proteomics approach to differentiate benign follicular thyroid adenoma (FTA) from malignant papillary thyroid carcinoma (PTC). Using LC-MRM mass spectrometry with stable isotope-labeled standards (SIS), we quantified a multiplex protein panel in plasma samples from 267 patients. The analytical workflow incorporated an MS-based assessment of preanalytical hemolysis to prevent bias associated with thyroid-related blood composition changes and multiple rounds of randomization allowed assessment of batch effects. While previously proposed low-abundance thyroid cancer markers were rarely detected in the cohort, a signature of high-abundance plasma proteins successfully stratified the patients. The malignant PTC phenotype was characterized by a significant increase in apolipoprotein A1 and myosin-9, along with elevated CD14 and kininogen-1. Benign FTA was associated with higher levels of acute-phase proteins, including ceruloplasmin and complement C1q subunit C. Simple PCRE model with 20 parameters based on 4 major plasma proteins allowed to build a classifier with specificity that can be adjusted with regard to epidemiology and medical resource. This study establishes a foundational mass spectrometry-based framework that utilizes systemic proteomic profiles to differentiate underlying pathologies and improve clinical decision-making regarding patient management. By enabling additional stratification of patients with Bethesda IV cytology, who are otherwise frequently subjected to unwarranted diagnostic operations, this multiplex MS approach provides a potential non-invasive triage tool to reduce unnecessary surgical interventions for indeterminate thyroid nodules.
Open AccessAutomated Multiplex Plasma Proteomics for Quality Assessment and Clinical Triage: A Proof-of-Concept in Indeterminate Thyroid Nodules
Fine-needle aspiration biopsy of thyroid nodules frequently yields indeterminate results, leading to unnecessary diagnostic surgeries. We evaluated a targeted plasma proteomics approach to differentiate benign follicular thyroid adenoma (FTA) from malignant papillary thyroid carcinoma (PTC). Using LC-MRM mass spectrometry with stable isotope-labeled standards (SIS), we quantified a multiplex protein panel in plasma samples from 267 patients. The analytical workflow incorporated an MS-based assessment of preanalytical hemolysis to prevent bias associated with thyroid-related blood composition changes and multiple rounds of randomization allowed assessment of batch effects. While previously proposed low-abundance thyroid cancer markers were rarely detected in the cohort, a signature of high-abundance plasma proteins successfully stratified the patients. The malignant PTC phenotype was characterized by a significant increase in apolipoprotein A1 and myosin-9, along with elevated CD14 and kininogen-1. Benign FTA was associated with higher levels of acute-phase proteins, including ceruloplasmin and complement C1q subunit C. Simple PCRE model with 20 parameters based on 4 major plasma proteins allowed to build a classifier with specificity that can be adjusted with regard to epidemiology and medical resource. This study establishes a foundational mass spectrometry-based framework that utilizes systemic proteomic profiles to differentiate underlying pathologies and improve clinical decision-making regarding patient management. By enabling additional stratification of patients with Bethesda IV cytology, who are otherwise frequently subjected to unwarranted diagnostic operations, this multiplex MS approach provides a potential non-invasive triage tool to reduce unnecessary surgical interventions for indeterminate thyroid nodules.
- 13 June 2025
- Published by Pleiades Publishing Ltd in Biochemistry (Moscow), Supplement Series A: Membrane and Cell Biology
- Vol. 19 (2) , 210-218
Humoral and Cellular Immune Response to the Genetically Detoxified S1 Subunit of Pertussis Toxin in Mice
Bordetella pertussis, a gram-negative bacterium responsible for whooping cough, poses severe health risks, especially to young children. However, the disease can be prevented by immunization with whole-cell pertussis vaccines and acellular pertussis vaccines containing 2–5 purified B. pertussis antigens, of which chemically detoxified pertussis toxin is the main protective component. While current vaccines have proven effective, concerns over high reactogenicity of whole-cell pertussis vaccines and the waning immunity to acellular pertussis vaccines formulations underscore the need for improved pertussis vaccines. Genetically detoxified pertussis toxin is an attractive vaccine candidate because it retains most of the structural properties of native pertussis toxin and better preserves the protective epitopes compared to detoxified pertussis toxin. In this study, we developed a candidate vaccine based on a genetically detoxified pertussis toxin S1 subunit, gd15PTxS1. We evaluated humoral and cellular immunogenicity of gd15PTxS1 in a murine model and demonstrated significant anti-PTx IgG seroconversion and a balanced Th1/Th2/Th17 T-cell response, with gd15PTxS1 inducing robust cytotoxic and helper T-cell activation comparable to that of the whole-cell pertussis vaccines. Our results show that gd15PTxS1 is highly immunogenic in mice and is a promising vaccine candidate for further protectivity studies.
- 13 June 2025
- Published by Pleiades Publishing Ltd in Biochemistry (Moscow), Supplement Series A: Membrane and Cell Biology
- Vol. 19 (2) , 210-218
Humoral and Cellular Immune Response to the Genetically Detoxified S1 Subunit of Pertussis Toxin in Mice
Bordetella pertussis, a gram-negative bacterium responsible for whooping cough, poses severe health risks, especially to young children. However, the disease can be prevented by immunization with whole-cell pertussis vaccines and acellular pertussis vaccines containing 2–5 purified B. pertussis antigens, of which chemically detoxified pertussis toxin is the main protective component. While current vaccines have proven effective, concerns over high reactogenicity of whole-cell pertussis vaccines and the waning immunity to acellular pertussis vaccines formulations underscore the need for improved pertussis vaccines. Genetically detoxified pertussis toxin is an attractive vaccine candidate because it retains most of the structural properties of native pertussis toxin and better preserves the protective epitopes compared to detoxified pertussis toxin. In this study, we developed a candidate vaccine based on a genetically detoxified pertussis toxin S1 subunit, gd15PTxS1. We evaluated humoral and cellular immunogenicity of gd15PTxS1 in a murine model and demonstrated significant anti-PTx IgG seroconversion and a balanced Th1/Th2/Th17 T-cell response, with gd15PTxS1 inducing robust cytotoxic and helper T-cell activation comparable to that of the whole-cell pertussis vaccines. Our results show that gd15PTxS1 is highly immunogenic in mice and is a promising vaccine candidate for further protectivity studies.