Mohammadreza Borzooei
Mohammadreza Borzooei has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Hadi Ghasemi
Department of Mechanical Engineering, University of Houston, 4726 Calhoun Rd, Houston, Texas 77204, United States
4 shared publications - Amirmohammad Jahanbakhsh3 shared publications
- Saber Badkoobeh Hezaveh3 shared publications
Rojan Firuznia
2 shared publications- Ben Xu
University of Texas Rio Grande Valley, Edinburg, TX
1 shared publication - Long Chang
Department of Electrical & Computer Engineering, University of Houston 2 , Houston, Texas 77204, USA
1 shared publication
Latest Publications
- Open Access
- 3 August 2026
- Published by Elsevier in SSRN Electronic Journal
System-Level Performance Assessment of a Thermochemical Salt-Hydrate Slurry Heat Transfer Fluid for Data Center Cooling
The rapid growth of artificial intelligence (AI) and high-performance computing (HPC) has significantly increased the cooling demand of modern data centers, making the development of energy-efficient thermal management technologies increasingly important. This study proposes a thermochemical paradigm for warm-water data-center cooling, in which thermochemical materials (TCMs) are dispersed into a heat-transfer fluid (HTF) to provide additional thermochemical heat absorption. The proposed concept is evaluated through a system-level analysis of its thermal, hydraulic, economic, and application performance. The thermophysical properties of 3 low-temperature TCM hydrates (Na₂SO₄·10H₂O, MgSO₄·7H₂O, and KAl(SO₄)₂·12H₂O) are modeled and their performance is assessed in a rear-door heat exchanger (RDHX) cooling system. Results show that the thermochemical system increases the effective heat-carrying capacity of the HTF, enabling the supply temperature to increase from 22 ℃ for the water baseline to approximately 30 ℃ while maintaining comparable RDHX heat-transfer performance. Although the increased slurry viscosity causes a moderate increase in pressure drop and pumping power, the higher HTF supply temperature substantially improves the chiller COP, leading to a 23.5% reduction in PUE−1, with Case B (10 wt.% Na₂SO₄·10H₂O) providing the best overall performance. Economic analysis indicates that, based on the IEA projection of 945 TWh global data-center electricity consumption in 2030 and if 30% of cooling demand is served by RDHX systems, the proposed thermochemical cooling concept could reduce worldwide RDHX-related annual electricity costs by approximately $817.9 million. Furthermore, under representative NVIDIA warm-water operating conditions (45/55 ℃), the concept further supports up to 78.4% higher IT thermal load or increases the coolant supply temperature from 45.0 to 52.2 °C at the same thermal load. These results demonstrate that the proposed thermochemical cooling concept provides a promising pathway toward improving both the energy efficiency and cooling capacity of next-generation warm-water data-center cooling systems.
- 3 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSystem-Level Performance Assessment of a Thermochemical Salt-Hydrate Slurry Heat Transfer Fluid for Data Center Cooling
The rapid growth of artificial intelligence (AI) and high-performance computing (HPC) has significantly increased the cooling demand of modern data centers, making the development of energy-efficient thermal management technologies increasingly important. This study proposes a thermochemical paradigm for warm-water data-center cooling, in which thermochemical materials (TCMs) are dispersed into a heat-transfer fluid (HTF) to provide additional thermochemical heat absorption. The proposed concept is evaluated through a system-level analysis of its thermal, hydraulic, economic, and application performance. The thermophysical properties of 3 low-temperature TCM hydrates (Na₂SO₄·10H₂O, MgSO₄·7H₂O, and KAl(SO₄)₂·12H₂O) are modeled and their performance is assessed in a rear-door heat exchanger (RDHX) cooling system. Results show that the thermochemical system increases the effective heat-carrying capacity of the HTF, enabling the supply temperature to increase from 22 ℃ for the water baseline to approximately 30 ℃ while maintaining comparable RDHX heat-transfer performance. Although the increased slurry viscosity causes a moderate increase in pressure drop and pumping power, the higher HTF supply temperature substantially improves the chiller COP, leading to a 23.5% reduction in PUE−1, with Case B (10 wt.% Na₂SO₄·10H₂O) providing the best overall performance. Economic analysis indicates that, based on the IEA projection of 945 TWh global data-center electricity consumption in 2030 and if 30% of cooling demand is served by RDHX systems, the proposed thermochemical cooling concept could reduce worldwide RDHX-related annual electricity costs by approximately $817.9 million. Furthermore, under representative NVIDIA warm-water operating conditions (45/55 ℃), the concept further supports up to 78.4% higher IT thermal load or increases the coolant supply temperature from 45.0 to 52.2 °C at the same thermal load. These results demonstrate that the proposed thermochemical cooling concept provides a promising pathway toward improving both the energy efficiency and cooling capacity of next-generation warm-water data-center cooling systems.
- 27 October 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 256
PINN-guided porous hierarchical structure for extreme thin film evaporation
- 27 October 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 256
PINN-guided porous hierarchical structure for extreme thin film evaporation
- 12 June 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 251
Accelerated wetting induced by nano-bumps
- 12 June 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 251
Accelerated wetting induced by nano-bumps