Andriy Zarubin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andriy Zarubin has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ihor Lavryk
O.M. Beketov National University of Urban Economy in Kharkiv
5 shared publications - Polina Pavlenko
Kharkiv National University of Radio Electronics
2 shared publications - Viktor Sergieiev
O.M. Beketov National University of Urban Economy in Kharkiv
2 shared publications - Ihor Biletskyi
O.M. Beketov National University of Urban Economy in Kharkiv
1 shared publication - Lidiia Piddubna
O.M. Beketov National University of Urban Economy in Kharkiv
1 shared publication
Latest Publications
- Open Access
- 31 March 2026
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Lighting Engineering & Power Engineering
- Vol. 65 (1) , 11-20
Algorithms for Digital Processing of Rheographic Signals for Non-Invasive Arterial Pressure Assessment
The article presents an algorithmic approach to the digital processing of rheographic signals for non-invasive arterial pressure assessment. The proposed method is based on a comprehensive analysis of the frequency structure of the rheosignal, enabling the separation of its low-frequency (first harmonic) and high-frequency components, which correspond to the global hemodynamic behavior and the local vascular properties, respectively. The study describes algorithms for signal filtering, baseline drift correction, segmentation, valid period selection, normalization, and averaging. It is demonstrated that separate processing of the low- and high-frequency components enhances the stability of the signal’s morphological features and enables the reconstruction of the arterial pressure waveform in the time domain. Calibration is performed using reference systolic and diastolic pressure values obtained by a standard measurement technique. The proposed approach provides a unified algorithmic structure for the assessment of both central and peripheral arterial pressure based on rheographic signals, thereby improving the accuracy and reproducibility of non-invasive pressure estimation.
- 31 March 2026
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Lighting Engineering & Power Engineering
- Vol. 65 (1) , 11-20
Open AccessAlgorithms for Digital Processing of Rheographic Signals for Non-Invasive Arterial Pressure Assessment
The article presents an algorithmic approach to the digital processing of rheographic signals for non-invasive arterial pressure assessment. The proposed method is based on a comprehensive analysis of the frequency structure of the rheosignal, enabling the separation of its low-frequency (first harmonic) and high-frequency components, which correspond to the global hemodynamic behavior and the local vascular properties, respectively. The study describes algorithms for signal filtering, baseline drift correction, segmentation, valid period selection, normalization, and averaging. It is demonstrated that separate processing of the low- and high-frequency components enhances the stability of the signal’s morphological features and enables the reconstruction of the arterial pressure waveform in the time domain. Calibration is performed using reference systolic and diastolic pressure values obtained by a standard measurement technique. The proposed approach provides a unified algorithmic structure for the assessment of both central and peripheral arterial pressure based on rheographic signals, thereby improving the accuracy and reproducibility of non-invasive pressure estimation.
- 25 December 2025
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Lighting Engineering & Power Engineering
- p. 119
Synchronous Multichannel Rheography for Cuffless Rheographic Assessment of the Ankle-Brachial Index: Experimental Evaluation of the Method
This study presents an experimental evaluation of a non-invasive cuffless method for as-sessing the ankle-brachial index based on synchronous multichannel rheography. The proposed approach is based on simultaneous acquisition of rheographic signals from the brachial and lower-leg leads, digital signal processing, averaging of pulse periods, and transformation of the averaged rheograms into pressure-equivalent pulse waveforms on a common relative scale. In contrast to the classical cuff-based determination of the ankle-brachial index, this method does not require sequential compression-based pressure measurements in the upper and lower limbs and enables analysis of pulsatile changes in both vascular regions under the same functional state of the cardiovascular system. The experimental material included synchronous rheographic recordings obtained from five subjects aged 55–65 years. For each subject, seven valid paired recordings of the brachial and lower-leg leads were analyzed. In each recording, a rheographic estimate of the ankle-brachial index was calculated from the amplitudes of the pressure-equivalent pulse wave-forms derived from the averaged rheograms, along with the ratio of the low-frequency and high-frequency components for the brachial and lower-leg leads. The coefficient of variation of the rheographic estimate of the ankle-brachial index ranged from 6.67 to 8.06%, indicating relatively low intra-individual variability across repeated recordings. The LF/HF ratio was higher in the lower-leg lead than in the brachial lead in all subjects. The obtained results confirm the feasibility of the proposed approach; however, the study should be regarded as an experimental evaluation rather than a clinical validation. Further research should focus on expanding the sample size and comparing the proposed method with clinically accepted reference methods for determining the ankle-brachial index.
- 25 December 2025
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Lighting Engineering & Power Engineering
- p. 119
Synchronous Multichannel Rheography for Cuffless Rheographic Assessment of the Ankle-Brachial Index: Experimental Evaluation of the Method
This study presents an experimental evaluation of a non-invasive cuffless method for as-sessing the ankle-brachial index based on synchronous multichannel rheography. The proposed approach is based on simultaneous acquisition of rheographic signals from the brachial and lower-leg leads, digital signal processing, averaging of pulse periods, and transformation of the averaged rheograms into pressure-equivalent pulse waveforms on a common relative scale. In contrast to the classical cuff-based determination of the ankle-brachial index, this method does not require sequential compression-based pressure measurements in the upper and lower limbs and enables analysis of pulsatile changes in both vascular regions under the same functional state of the cardiovascular system. The experimental material included synchronous rheographic recordings obtained from five subjects aged 55–65 years. For each subject, seven valid paired recordings of the brachial and lower-leg leads were analyzed. In each recording, a rheographic estimate of the ankle-brachial index was calculated from the amplitudes of the pressure-equivalent pulse wave-forms derived from the averaged rheograms, along with the ratio of the low-frequency and high-frequency components for the brachial and lower-leg leads. The coefficient of variation of the rheographic estimate of the ankle-brachial index ranged from 6.67 to 8.06%, indicating relatively low intra-individual variability across repeated recordings. The LF/HF ratio was higher in the lower-leg lead than in the brachial lead in all subjects. The obtained results confirm the feasibility of the proposed approach; however, the study should be regarded as an experimental evaluation rather than a clinical validation. Further research should focus on expanding the sample size and comparing the proposed method with clinically accepted reference methods for determining the ankle-brachial index.
- 1 October 2025
- Published by Springer Nature
- p. 56-70
Experimental Study of the Rheographic Method for Assessing Endothelial Function
- 1 October 2025
- Published by Springer Nature
- p. 56-70
Experimental Study of the Rheographic Method for Assessing Endothelial Function
- Open Access
- 29 April 2025
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Lighting Engineering & Power Engineering
- Vol. 64 (1) , 125-137
Assessment of the state of the vascular system based on the results of rheographic measurements
The reasons for the decline in interest in the rheographic method of studying the state of the cardiovascular system, proposed in the forties of the last century as a new promising research method, are considered. It is shown that the noted shortcomings of the method are not related to its fundamental capabilities, but to the inadequacy of the proposed method of analysis and interpretation of the obtained data, which underlies the classical method used today for assessing the state of the cardiovascular system based on the results of rheographic studies. The classical method proposed completely unfounded information parameters and unclear formal rules for their evaluation, which do not allow the observed features of the rheographic signal to be linked to the hemodynamic features of the pa-tient’s cardiovascular system. The article examines the causes of errors in assessing the state of the cardiovascular system that arise when using the classical method of analysis and suggests possible ways to im-prove the method. The potential of using rheography is shown not only for the adequate assessment of its traditional parameters, such as blood filling of arterial vessels, tone of vessels of various calibers, peripheral resistance, and the state of venous outflow. It is also demonstrated to be effective for the highly accurate assessment of peripheral and central arterial pressure. Rheography can improve the accuracy of determining the speed of pulse wave propagation in arterial vessels. It also enhances the precision of the ankle-brachial index when evaluating the condition of the arteries in the patient's lower extremities. Finally, rheography can be used to assess the functional state of the endothelium in arteri-al vessels. It is shown that the rheographic method allows obtaining all these data using simpler methods compared to the methods currently used for similar purposes and using cheaper equipment. In addition, the use of rheography makes it possible to obtain higher accuracy in assessing the parameters of interest.
- 29 April 2025
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Lighting Engineering & Power Engineering
- Vol. 64 (1) , 125-137
Open AccessAssessment of the state of the vascular system based on the results of rheographic measurements
The reasons for the decline in interest in the rheographic method of studying the state of the cardiovascular system, proposed in the forties of the last century as a new promising research method, are considered. It is shown that the noted shortcomings of the method are not related to its fundamental capabilities, but to the inadequacy of the proposed method of analysis and interpretation of the obtained data, which underlies the classical method used today for assessing the state of the cardiovascular system based on the results of rheographic studies. The classical method proposed completely unfounded information parameters and unclear formal rules for their evaluation, which do not allow the observed features of the rheographic signal to be linked to the hemodynamic features of the pa-tient’s cardiovascular system. The article examines the causes of errors in assessing the state of the cardiovascular system that arise when using the classical method of analysis and suggests possible ways to im-prove the method. The potential of using rheography is shown not only for the adequate assessment of its traditional parameters, such as blood filling of arterial vessels, tone of vessels of various calibers, peripheral resistance, and the state of venous outflow. It is also demonstrated to be effective for the highly accurate assessment of peripheral and central arterial pressure. Rheography can improve the accuracy of determining the speed of pulse wave propagation in arterial vessels. It also enhances the precision of the ankle-brachial index when evaluating the condition of the arteries in the patient's lower extremities. Finally, rheography can be used to assess the functional state of the endothelium in arteri-al vessels. It is shown that the rheographic method allows obtaining all these data using simpler methods compared to the methods currently used for similar purposes and using cheaper equipment. In addition, the use of rheography makes it possible to obtain higher accuracy in assessing the parameters of interest.