Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Minhui Liang has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simulation-Based Microfluidic Deformation Mapping for Region-Dependent Apparent Young’s Modulus Estimation of Single Cells

    by Minhui Liang, Yilong Zhou, Dawei Ming, Jiawei Lyu, Jianwei Zhong, Han Li, Lin Lin

    High-throughput microfluidic deformation assays enable label-free single-cell mechanophenotyping by quantifying how cells deform under controlled hydrodynamic loading. These approaches commonly extract deformation-related observables, such as projected area, axis ratio, and deformation index, and use them as indicators for cellular mechanical properties. However, deformation is not solely determined by stiffness; it is a coupled outcome of cell size, local hydrodynamic stress, and intrinsic mechanical response. Therefore, we present a simulation-based microfluidic framework for estimating region-dependent apparent Young’s modulus (E, a quantitative indicator characterizing cellular mechanical stiffness) from diameter–deformation measurements at the single-cell level. A three-region microfluidic channel is designed to impose distinct hydrodynamic loading conditions, while numerical simulations establish quantitative maps linking cell diameter, deformation, and E. Based on these results, region-specific nonlinear surface models are constructed to invert experimental diameter–deformation measurements into E values. Finally, application to primary T cells and K562 cells demonstrates clear region-dependent differences in E, highlighting the influence of local loading conditions on inferred mechanical properties. Overall, this work provides a simplified but practical route for transforming deformation-based phenotypes into quantitative, loading-aware mechanical parameters for single-cell analysis.

  • Open Access

    Non-Invasive Three-Dimensional Cell Manipulation Technology Based on Acoustic Microfluidic Chips

    by Lin Lin, Yiming Zhen, Wang Li, Guoqiang Dong, Rongxing Zhu, Minhui Liang

    This study presents a non-invasive three-dimensional cell manipulation technique based on acoustic microfluidic chips, which generates acoustic flow fields through the vibration of micropillars induced by bulk acoustic waves to achieve precise multi-dimensional rotational manipulation of cells. Moreover, the characteristics of the acoustic flow field under linear, quasi-circular, elliptical, and higher-order vibration modes were intensively studied, and the rotational manipulation performance of polystyrene microbeads and cancer cells was optimized by adjusting the frequency and voltage. The results showed that the rotational speed and direction of the particles varied significantly in different vibration modes, with the particles and cells achieving the highest rotational speed in the elliptical vibration mode (frequency: 44.9 kHz, and voltage: 60 Vpp). In addition, the technique successfully achieved in-plane and out-of-plane rotation of cancer cells, and cell viability tests showed that 94% of the cells remained active after manipulation, demonstrating the low damage and biocompatibility of the method. This study provides a new, efficient, precise and gentle approach to three-dimensional manipulation of cells, which holds significant potential in biomedical research and clinical applications.


  • On-Demand Nanoliter Delivering Platform via Electrical-Activated Microdroplet Assembling

    by Jianwei Zhong, Yifu Chang, Minhui Liang, Yinning Zhou, Ye Ai

    Precise delivery of nanoliter-scale reagents is essential for high-throughput biochemical assays, yet existing platforms often lack real-time control and selective content fusion. Conventional methods rely on passive encapsulation or stochastic pairing, limiting both throughput and biochemical specificity. Here, we introduce an on-demand nanoliter delivery platform that seamlessly integrates electrical sensing, triggered droplet merging, and passive sorting in a single continuous flow. Leveraging impedance-based content detection, the system selectively identifies target droplets and initiates electrocoalescence-based fusion only when specific biochemical criteria are met. Fused nanoliter droplets are then sorted via size-dependent hydrodynamic deflection, enabling energy-free enrichment. Applied to bacterial screening, the system accurately distinguishes metabolically active droplets and could achieve over 6000 events per minute with postfusion purity exceeding 92%. This platform provides a label-free, high-precision solution for programmable nanoliter delivery, offering broad potential for drug discovery, synthetic biology, and single-cell analysis applications.

  • Top Cited Papers
    Open Access

    Pathophysiological Associations and Measurement Techniques of Red Blood Cell Deformability

    by Minhui Liang, Dawei Ming, Jianwei Zhong, Choo Sheriel Shannon, William Rojas-Carabali, Kajal Agrawal, Ye Ai, Rupesh Agrawal

    Red blood cell (RBC), accounting for approximately 45% of total blood volume, are essential for oxygen delivery and carbon dioxide removal. Their unique biconcave morphology, high surface area-to-volume ratio, and remarkable deformability enable them to navigate microvessels narrower than their resting diameter, ensuring efficient microcirculation. RBC deformability is primarily determined by membrane viscoelasticity, cytoplasmic viscosity, and cell geometry, all of which can be altered under various physiological and pathological conditions. Reduced deformability is a hallmark of numerous diseases, including sickle cell disease, malaria, diabetes mellitus, sepsis, ischemia–reperfusion injury, and storage lesions in transfused blood. As these mechanical changes often precede overt clinical symptoms, RBC deformability is increasingly recognized as a sensitive biomarker for disease diagnosis, prognosis, and treatment monitoring. Over the past decades, diverse techniques have been developed to measure RBC deformability. These include single-cell methods such as micropipette aspiration, optical tweezers, atomic force microscopy, magnetic twisting cytometry, and quantitative phase imaging; bulk approaches like blood viscometry, ektacytometry, filtration assays, and erythrocyte sedimentation rate; and emerging microfluidic platforms capable of high-throughput, physiologically relevant measurements. Each method captures distinct aspects of RBC mechanics, offering unique advantages and limitations. This review synthesizes current knowledge on the pathophysiological significance of RBC deformability and the methods for its measurement. We discuss disease contexts in which deformability is altered, outline mechanical models describing RBC viscoelasticity, and provide a comparative analysis of measurement techniques. Our aim is to guide the selection of appropriate approaches for research and clinical applications, and to highlight opportunities for developing robust, clinically translatable diagnostic tools.


  • Dynamically Tunable Optofluidic Multifocal Microlens Arrays by 3D Printing

    by Li Liang, Jin Du, Wang Zhang, Heyun Zhang, Yifan Wang, Minhui Liang, Feng Liao, Jianping Shi, Joel K.W. Yang, Zewen Zuo, et al.

    Microlens arrays (MLAs) are key components in 3D integrated imaging optical systems, particularly the multifocal MLAs, which provide a new strategy to break through the depth-of-field limitations for 3D imaging. However, the focal lengths of most existing multifocal MLAs that are produced by solid materials are fixed, making it difficult to meet dynamic imaging requirements with a large depth of field. In this article, we innovatively propose dynamically tunable multifocal MLAs using fluid as the lens material, which is integrated into a three-dimensional optofluidic chip fabricated by two-photon 3D printing technology. The fluid multifocal MLAs are realized by filling a microcavity array with flow streams of a gradient refractive index (RI) distribution, which is formed through convection and diffusion between miscible liquids of different RIs. By changing the flow rates, the RI distribution in the microcavity array can be readily regulated; thus, the optical characteristics of the MLAs can be dynamically tuned. The modulation mechanism is revealed by combining theoretical analysis, numerical simulations, and experimental observations. Thanks to the excellent regulatability of fluids by optofluidics, the present fluid MLA offers a wide adjustment range for the focal length, numerical aperture, and focal spot intensity. Especially, it possesses the ability to rapidly switch between different focal planes (flat, concave, and multiple-curved focal planes). Furthermore, the imaging applications of fluid MLAs are demonstrated using fluorescent microparticles and fluorescence-stained cells as samples, which exhibit enhanced magnification and improved clarity. This adaptability supports dynamic sample observation, highlighting the great potential of optofluidic multifocal MLAs for applications requiring large depth-of-field imaging.


  • A Systematic Study of Size Correlation and Young's Modulus Sensitivity for Cellular Mechanical Phenotyping by Microfluidic Approaches

    by Minhui Liang, Jianwei Zhong, Ye Ai

    Cellular mechanical properties are a class of intrinsic biophysical markers for cell state and health. Microfluidic mechanical phenotyping methods have emerged as promising tools to overcome the challenges of low throughput and high demand for manual skills in conventional approaches. In this work, two types of microfluidic cellular mechanical phenotyping methods, contactless hydro‐stretching deformability cytometry (lh‐DC) and contact constriction deformability cytometry (cc‐DC) are comprehensively studied and compared. Polymerized hydrogel beads with defined sizes are used to characterize a strong negative correlation between size and deformability in cc‐DC (r = −0.95), while lh‐DC presents a weak positive correlation (r = 0.13). Young's modulus sensitivity in cc‐DC is size‐dependent while it is a constant in lh‐DC. Moreover, the deformability assessment for human breast cell line mixture suggests the lh‐DC exhibits better differentiation capability of cells with different size distributions, while cc‐DC provides higher sensitivity to identify cellular mechanical changes within a single cell line. This work is the first to present a quantitative study and comparison of size correlation and Young's modulus sensitivity of contactless and contact microfluidic mechanical phenotyping methods, which provides guidance to choose the most suitable cellular mechanical phenotyping platform for specific cell analysis applications.


  • Biosensors for single-cell mechanical characterization

    by Minhui Liang, Jianwei Zhong, Ye Ai

  • Single-Cell Stretching in Viscoelastic Fluids with Electronically Triggered Imaging for Cellular Mechanical Phenotyping

    by Minhui Liang, Dahou Yang, Yinning Zhou, Peixian Li, Jianwei Zhong, Ye Ai

    Cellular mechanical phenotypes in connection to physiological and pathological states of cells have become a promising intrinsic biomarker for label-free cell analysis in various biological research and medical diagnostics. In this work, we present a microfluidic system capable of high-throughput cellular mechanical phenotyping based on a rapid single-cell hydrodynamic stretching in a continuous viscoelastic fluid flow. Randomly introduced single cells are first aligned into a single streamline in viscoelastic fluids before being guided to a flow splitting junction for consistent hydrodynamic stretching. The arrival of individual cells prior to the flow splitting junction can be detected by an electrical sensing unit, which produces a triggering signal to activate a high-speed camera for on-demand imaging of the cell motion and deformation through the flow splitting junction. Cellular mechanical phenotypes, including cell size and cell deformability, are extracted from the analysis of these captured single-cell images. We have evaluated the sensitivity of the developed microfluidic mechanical phenotyping system by measuring the synthesized hydrogel microbeads with known Young’s modulus. With this microfluidic cellular mechanical phenotyping system, we have revealed the statistical difference in the deformability of microfilament disrupted, normal, and fixed NIH 3T3 fibroblast cells. Furthermore, with the implementation of a machine-learning-based classification of MCF-10A and MDA-MB-231 mixtures, our label-free cellular phenotyping system has achieved a comparable cell analysis accuracy (0.9:1, 5.03:1) with respect to the fluorescence-based flow cytometry results (0.97:1, 5.33:1). The presented microfluidic mechanical phenotyping technique will open new avenues for high-throughput and label-free single-cell analysis in diverse biomedical applications.