Hongsheng Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hongsheng Xu has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Meng Zhan
Huazhong University of Science and Technology
2 shared publications Jiawei Yu
State Key Laboratory of HVDC (Electric Power Research Institute Guangdong Provincial Key Laboratory of Intelligent Operation and Control for New Energy Power System CSG Key Laboratory for Power System Simulation (Electric Power Research Institute China Southern Power Grid) National Energy Power Grid Technology R&D Centre China Southern Power Grid) Guangzhou China
1 shared publicationMin Cheng
Yunnan Power Grid Kunming China
1 shared publicationQi Guo
State Key Laboratory of HVDC (Electric Power Research Institute Guangdong Provincial Key Laboratory of Intelligent Operation and Control for New Energy Power System CSG Key Laboratory for Power System Simulation (Electric Power Research Institute China Southern Power Grid) National Energy Power Grid Technology R&D Centre China Southern Power Grid) Guangzhou China
1 shared publication
Latest Publications
- 2 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (3) , 3894-3911
Transient Synchronization Stability Analysis and Assessment of DFIG System Under Severe Faults
In the transient stability analysis of renewable energy grid-tied systems, although a large amount of works have been devoted to the detailed electromagnetic transient simulation and the stability analyses of during-fault stage, the whole low-voltage ride through (LVRT) process and transient stability mechanism remain to be uncovered. Taking the doubly fed induction generator (DFIG) system as an objective, this article divides its transient processes into four different stages, including the prefault, during-fault, early postfault, and late postfault ones, establishes the full mechanism models for each stage, and studies the sequential switching dynamics in detail. It is found that the during-fault dynamics can be determined by the phase-lock loop second-order equation within the framework of the generalized swing equation (GSE), with additive scaled parameters. In particular, for the early postfault stage dynamics, it can be treated as a series of quasisteady states and its dominant driving system dynamics can still be described by the GSE. Thus the system transient stability can be completely determined by whether the initial state of the early postfault stage is within or out of its corresponding basin of attraction (BOA). Based on these unique dynamical characteristics, the BOA-based and equal area criterion-based transient stability assessment methods are developed, which are supported by broad numerical simulations and hardware-in-the-loop experiments. This work provides a clear physical picture and perfectly solves the difficult stability analysis problem when severe faults and LVRT showing discontinuous switching dynamics have to be considered in most of DFIG engineering situations.
- 2 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (3) , 3894-3911
Transient Synchronization Stability Analysis and Assessment of DFIG System Under Severe Faults
In the transient stability analysis of renewable energy grid-tied systems, although a large amount of works have been devoted to the detailed electromagnetic transient simulation and the stability analyses of during-fault stage, the whole low-voltage ride through (LVRT) process and transient stability mechanism remain to be uncovered. Taking the doubly fed induction generator (DFIG) system as an objective, this article divides its transient processes into four different stages, including the prefault, during-fault, early postfault, and late postfault ones, establishes the full mechanism models for each stage, and studies the sequential switching dynamics in detail. It is found that the during-fault dynamics can be determined by the phase-lock loop second-order equation within the framework of the generalized swing equation (GSE), with additive scaled parameters. In particular, for the early postfault stage dynamics, it can be treated as a series of quasisteady states and its dominant driving system dynamics can still be described by the GSE. Thus the system transient stability can be completely determined by whether the initial state of the early postfault stage is within or out of its corresponding basin of attraction (BOA). Based on these unique dynamical characteristics, the BOA-based and equal area criterion-based transient stability assessment methods are developed, which are supported by broad numerical simulations and hardware-in-the-loop experiments. This work provides a clear physical picture and perfectly solves the difficult stability analysis problem when severe faults and LVRT showing discontinuous switching dynamics have to be considered in most of DFIG engineering situations.
- Open Access
- 20 May 2025
- Published by Institution of Engineering and Technology (IET) in Energy Internet
- Vol. 2 (2) , 174-183
Singular Perturbation and Complex Torque Analyses of Doubly Fed Induction Generator With Additional Inertia Control
The doubly fed induction generator (DFIG) shows multi‐time‐scale and strong nonlinearity, making its stability analysis difficult. This paper conducts small perturbation stability analysis for the single‐DFIG infinite‐bus system with additional inertia control (AIC). First, the full‐order electromagnetic transient model is constructed based on its topology and control structure. Then, the original model is reduced by using the singular perturbation method, and the validity of the simplified sixth‐order model is verified by simulation. After linearising the sixth‐order model based on the root locus and frequency response diagrams, it is found that increasing the gain coefficient K f of the AIC could improve the inertia response characteristics but weaken the system's small disturbance stability. Furthermore, a complex torque model is constructed, which reveals that the system's negative damping originates from the terminal voltage control loop. Moreover, as K f increases, the inherent damping continuously decreases, leading to further deterioration of the negative damping. As T f increases, the stability of the system initially weakens and then strengthens. This study could help understand the DFIG grid‐tied system dynamics.
- 20 May 2025
- Published by Institution of Engineering and Technology (IET) in Energy Internet
- Vol. 2 (2) , 174-183
Open AccessSingular Perturbation and Complex Torque Analyses of Doubly Fed Induction Generator With Additional Inertia Control
The doubly fed induction generator (DFIG) shows multi‐time‐scale and strong nonlinearity, making its stability analysis difficult. This paper conducts small perturbation stability analysis for the single‐DFIG infinite‐bus system with additional inertia control (AIC). First, the full‐order electromagnetic transient model is constructed based on its topology and control structure. Then, the original model is reduced by using the singular perturbation method, and the validity of the simplified sixth‐order model is verified by simulation. After linearising the sixth‐order model based on the root locus and frequency response diagrams, it is found that increasing the gain coefficient K f of the AIC could improve the inertia response characteristics but weaken the system's small disturbance stability. Furthermore, a complex torque model is constructed, which reveals that the system's negative damping originates from the terminal voltage control loop. Moreover, as K f increases, the inherent damping continuously decreases, leading to further deterioration of the negative damping. As T f increases, the stability of the system initially weakens and then strengthens. This study could help understand the DFIG grid‐tied system dynamics.