Lucie C. Vermeulen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lucie C. Vermeulen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Christiaan Delmaar
Centre for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, Netherlands
1 shared publication - Erwin Duizer
Centre for Infectious Disease Control , National Institute for Public Health and the Environment (RIVM) , Bilthoven , the Netherlands , rivm.nl
1 shared publication - Gabriel Goderski
Centre for Infectious Disease Control, National Institute for Public Health and the Environment, Bilthoven, The Netherlands
1 shared publication - Ingmar Janse
Centre for Infectious Disease Control , National Institute for Public Health and the Environment (RIVM) , Bilthoven , the Netherlands , rivm.nl
1 shared publication - J. Kocken
Centre for Infectious Disease Control , National Institute for Public Health and the Environment (RIVM) , Bilthoven , the Netherlands , rivm.nl
1 shared publication - Jack F. Schijven
Environmental Hydrogeology Group, Geosciences Utrecht University Utrecht The Netherlands
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Wiley in Indoor Air
- Vol. 2026 (1) , 5068026
Sampler‐Induced Loss of Respiratory Virus Infectivity Revealed by Spiked Collection‐Liquid Experiments
Understanding the transmission risk of respiratory viruses in indoor environments requires reliable detection of infectious particles in air samples. However, mechanical stress during air sampling may reduce the survival of infectious virus, complicating accurate assessment. This study investigated the impact of air sampler‐induced mechanical stress on the RNA recovery and infectivity of rhinovirus, SARS‐CoV‐2 and influenza A virus using the Coriolis μ liquid impinger in an experimental setting with spiked collection liquids rather than aerosol or ambient air collection. Collection liquids were spiked with known virus concentrations and subjected to different airflow rates. Infectious virus titres and viral RNA copies were quantified by culture and PCR, respectively. Results demonstrated substantial reductions in culturable virus for SARS‐CoV‐2 and influenza A virus (up to 98.6% loss) at the tested airflow speeds, whereas rhinovirus changes were minimal and of limited biological significance. Viral RNA concentrations remained mostly unchanged throughout all airflow speeds for SARS‐CoV‐2 and rhinovirus, but were reduced for influenza A virus. These findings suggest that mechanical stress caused by an air sampling device can significantly decrease the recovery of infectious viruses, which could lead to underestimation of the presence of infectious virus. Our results emphasise the need to account for virus‐specific stability and sampler‐induced inactivation when interpreting data from air sampling studies and assessing airborne transmission risk.
- 1 January 2026
- Published by Wiley in Indoor Air
- Vol. 2026 (1) , 5068026
Open AccessSampler‐Induced Loss of Respiratory Virus Infectivity Revealed by Spiked Collection‐Liquid Experiments
Understanding the transmission risk of respiratory viruses in indoor environments requires reliable detection of infectious particles in air samples. However, mechanical stress during air sampling may reduce the survival of infectious virus, complicating accurate assessment. This study investigated the impact of air sampler‐induced mechanical stress on the RNA recovery and infectivity of rhinovirus, SARS‐CoV‐2 and influenza A virus using the Coriolis μ liquid impinger in an experimental setting with spiked collection liquids rather than aerosol or ambient air collection. Collection liquids were spiked with known virus concentrations and subjected to different airflow rates. Infectious virus titres and viral RNA copies were quantified by culture and PCR, respectively. Results demonstrated substantial reductions in culturable virus for SARS‐CoV‐2 and influenza A virus (up to 98.6% loss) at the tested airflow speeds, whereas rhinovirus changes were minimal and of limited biological significance. Viral RNA concentrations remained mostly unchanged throughout all airflow speeds for SARS‐CoV‐2 and rhinovirus, but were reduced for influenza A virus. These findings suggest that mechanical stress caused by an air sampling device can significantly decrease the recovery of infectious viruses, which could lead to underestimation of the presence of infectious virus. Our results emphasise the need to account for virus‐specific stability and sampler‐induced inactivation when interpreting data from air sampling studies and assessing airborne transmission risk.
- Open Access
- 1 January 2025
- Published by Wiley in Indoor Air
- Vol. 2025 (1)
Modelling Near‐Field Aerosol Exposure for Respiratory Infection Risk Assessment
Quantitative microbiological risk assessment (QMRA) is a method to estimate the risk of infectious disease transmission from human exposure to pathogens. QMRA is a helpful tool to inform health policies to control the impact of infectious disease transmission from human‐to‐human transmissible infectious respiratory diseases. QMRA combines an estimate of pathogen exposure with information on the probability of infection given the dose. The infection risk of respiratory diseases is generally assumed to depend on the interpersonal distance between the infectious person (index) and the exposed recipient. To account for close‐proximity exposure in QMRA, specific generic models are required. To be helpful in policy information, these models should be sufficiently accurate in describing elevated air concentrations of pathogens near the index. On the other hand, they should be sufficiently generic and flexible to be applied in generalized situations without requiring very specific and detailed situational information. In this work, we identified different models to account for near‐field exposure in the literature: multizone, diffusion, and jet models. These methods were tested with respect to their applicability in QMRA. We evaluated them on the criteria of ease of use, the availability of parameter values for generic application, and their ability to describe air concentrations in realistic situations as replicated in experiments. It was found that only diffusion modelling appeared to be both flexible enough to describe experimental data and to be supported by sufficient information to allow for parametrization in a wide variety of situations. The multizone models were found to be easy to use but difficult to parametrize given the arbitrariness of aspects of the modelling method. The jet models were found to be more complex to implement and adapt to specific exposure scenarios.
- 1 January 2025
- Published by Wiley in Indoor Air
- Vol. 2025 (1)
Open AccessModelling Near‐Field Aerosol Exposure for Respiratory Infection Risk Assessment
Quantitative microbiological risk assessment (QMRA) is a method to estimate the risk of infectious disease transmission from human exposure to pathogens. QMRA is a helpful tool to inform health policies to control the impact of infectious disease transmission from human‐to‐human transmissible infectious respiratory diseases. QMRA combines an estimate of pathogen exposure with information on the probability of infection given the dose. The infection risk of respiratory diseases is generally assumed to depend on the interpersonal distance between the infectious person (index) and the exposed recipient. To account for close‐proximity exposure in QMRA, specific generic models are required. To be helpful in policy information, these models should be sufficiently accurate in describing elevated air concentrations of pathogens near the index. On the other hand, they should be sufficiently generic and flexible to be applied in generalized situations without requiring very specific and detailed situational information. In this work, we identified different models to account for near‐field exposure in the literature: multizone, diffusion, and jet models. These methods were tested with respect to their applicability in QMRA. We evaluated them on the criteria of ease of use, the availability of parameter values for generic application, and their ability to describe air concentrations in realistic situations as replicated in experiments. It was found that only diffusion modelling appeared to be both flexible enough to describe experimental data and to be supported by sufficient information to allow for parametrization in a wide variety of situations. The multizone models were found to be easy to use but difficult to parametrize given the arbitrariness of aspects of the modelling method. The jet models were found to be more complex to implement and adapt to specific exposure scenarios.