Shuo Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuo Zhang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Hui Huang
School of Control Science and Engineering, Dalian University of Technology, Dalian, China
1 shared publication - Huolin Huang
Central Hospital of Dalian University of Technology, Dalian, P.R. China
1 shared publication - Jianchao Fan
Dalian University of Technology
1 shared publication - Jien Song
Jiangsu Shenyuan Marine Information Technology and Equipment Innovation Center Company Ltd., Suzhou, China
1 shared publication - Jing Chen
School of Control Science and Engineering, Dalian University of Technology, Dalian, China
1 shared publication - Pei Guo
School of Mechanical Engineering, Dalian University of Technology, Dalian, China
1 shared publication
Latest Publications
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
A Compact and Sensitive Metal-Capillary Fluorometer: Application to Online Monitoring Oil Spill
Due to the frequent occurrence of marine oil spill accidents and related ecological pollution, online detection of oil-slick thickness is important. Fluorescence detection of oil slick has the advantages of high sensitivity and no need of reagent. Herein, a compact and sensitive fluorometer consisted of two metal capillary (MC), a UV LED and a linear variable filter (LVF), was developed for oil slick detection in a non-contact way. The two MCs are used to transmit UV light and collect fluorescence above the oil slick, respectively, and the angle between them is 45 degrees (V-shaped MCs). By employing MCs, the detection signal-to-noise ratio (SNR) can be improved by 34.5 times, and the limit of detection (LOD) of oil slick thickness is as low as 0.035 µm. The relationship between the fluorescence signal and the oil slick thickness features good linearity (R2 = 0.998) in a range of 0.035 ~ 20 µm. The spectrometer would be suitable for online monitoring marine oil spill.
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
A Compact and Sensitive Metal-Capillary Fluorometer: Application to Online Monitoring Oil Spill
Due to the frequent occurrence of marine oil spill accidents and related ecological pollution, online detection of oil-slick thickness is important. Fluorescence detection of oil slick has the advantages of high sensitivity and no need of reagent. Herein, a compact and sensitive fluorometer consisted of two metal capillary (MC), a UV LED and a linear variable filter (LVF), was developed for oil slick detection in a non-contact way. The two MCs are used to transmit UV light and collect fluorescence above the oil slick, respectively, and the angle between them is 45 degrees (V-shaped MCs). By employing MCs, the detection signal-to-noise ratio (SNR) can be improved by 34.5 times, and the limit of detection (LOD) of oil slick thickness is as low as 0.035 µm. The relationship between the fluorescence signal and the oil slick thickness features good linearity (R2 = 0.998) in a range of 0.035 ~ 20 µm. The spectrometer would be suitable for online monitoring marine oil spill.