João Paulo Liute Scarramal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
João Paulo Liute Scarramal has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Marcio Yuri Ferreira
Department of Neurosurgery, Lenox Hill Hospital/Northwell Health, New York, NY
2 shared publications - Ahmet Günkan
Division of Vascular and Interventional Radiology, Department of Radiology and Imaging Sciences, University of Arizona, Tucson, USA
1 shared publication - Christian Ferreira
Phelps Hospital, Northwell Health
1 shared publication - Christian Ferreira
Department of Neurosurgery, Northwell Health, New York, United States
1 shared publication - David Gordon
Phelps Hospital, Sleepy Hollow, United States
1 shared publication - David J. Langer
Department of Neurosurgery, Lenox Hill Hospital/Northwell Health
1 shared publication
Latest Publications
- 17 June 2025
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (8) , 1669-1681
Diagnostic accuracy of ultrasonographic optic nerve sheath diameter compared to invasive ICP monitoring for intracranial hypertension in pediatric patients
Background Monitoring intracranial pressure (ICP) is essential in pediatric neurocritical care, but invasive methods pose risks, highlighting the need for accurate non-invasive alternatives like ultrasonographic optic nerve sheath diameter (ONSD) measurement. Objective To evaluate the diagnostic accuracy of ultrasonographic measurement of the ONSD for detecting elevated ICP in children, stratified by age (< 1 year or > 1 year). Materials and methods A systematic search was conducted in PubMed, Embase, and Cochrane from inception to February 3, 2025. Eligible studies included prospective or retrospective cohorts and randomized trials comparing ultrasonographic ONSD with invasive ICP measurements (mmHg) in pediatric patients, reporting data for a 2 × 2 table. The analyses included (1) sensitivity; (2) specificity; (3) summary receiver operating characteristic curve; (4) area under the curve; (5) diagnostic odds ratio; and (6) likelihood ratios. A random-effects model was used, with 95% confidence intervals and subgroup differences assessed (P < 0.05 statistically significant). Results Seven studies with 380 patients were included. ONSD cutoffs ranged from 4.0 mm to 5.29 mm across studies. For the 20 mmHg cutoff (n = 369), sensitivity was 91.6% [95% CI, 83.2–96.0] and specificity was 71.9% [95% CI, 65.4–77.6]. For the 15 mmHg cutoff (n = 304), sensitivity was 89.3% [95% CI, 83.9–93.1] and specificity was 76.2% [95% CI, 68.0–82.8]. Sensitivity differences by age were statistically significant at 20 mmHg (P = 0.03), with 245 patients > 1 year (sensitivity, 90.1% [95% CI, 83.3–94.3]) and 124 patients < 1 year (sensitivity, 75.7% [95% CI, 59.5–86.8]). Conclusion The diagnostic accuracy of ultrasound-measured ONSD in detecting intracranial hypertension was high in pediatric patients, although sensitivity varied with age. These findings highlight the importance of age-stratified analyses to assess ONSD accuracy, particularly in infants. Graphical Abstract
- 17 June 2025
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (8) , 1669-1681
Diagnostic accuracy of ultrasonographic optic nerve sheath diameter compared to invasive ICP monitoring for intracranial hypertension in pediatric patients
Background Monitoring intracranial pressure (ICP) is essential in pediatric neurocritical care, but invasive methods pose risks, highlighting the need for accurate non-invasive alternatives like ultrasonographic optic nerve sheath diameter (ONSD) measurement. Objective To evaluate the diagnostic accuracy of ultrasonographic measurement of the ONSD for detecting elevated ICP in children, stratified by age (< 1 year or > 1 year). Materials and methods A systematic search was conducted in PubMed, Embase, and Cochrane from inception to February 3, 2025. Eligible studies included prospective or retrospective cohorts and randomized trials comparing ultrasonographic ONSD with invasive ICP measurements (mmHg) in pediatric patients, reporting data for a 2 × 2 table. The analyses included (1) sensitivity; (2) specificity; (3) summary receiver operating characteristic curve; (4) area under the curve; (5) diagnostic odds ratio; and (6) likelihood ratios. A random-effects model was used, with 95% confidence intervals and subgroup differences assessed (P < 0.05 statistically significant). Results Seven studies with 380 patients were included. ONSD cutoffs ranged from 4.0 mm to 5.29 mm across studies. For the 20 mmHg cutoff (n = 369), sensitivity was 91.6% [95% CI, 83.2–96.0] and specificity was 71.9% [95% CI, 65.4–77.6]. For the 15 mmHg cutoff (n = 304), sensitivity was 89.3% [95% CI, 83.9–93.1] and specificity was 76.2% [95% CI, 68.0–82.8]. Sensitivity differences by age were statistically significant at 20 mmHg (P = 0.03), with 245 patients > 1 year (sensitivity, 90.1% [95% CI, 83.3–94.3]) and 124 patients < 1 year (sensitivity, 75.7% [95% CI, 59.5–86.8]). Conclusion The diagnostic accuracy of ultrasound-measured ONSD in detecting intracranial hypertension was high in pediatric patients, although sensitivity varied with age. These findings highlight the importance of age-stratified analyses to assess ONSD accuracy, particularly in infants. Graphical Abstract
- 16 June 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (7) , 1859-1872
Safety and efficacy of the Woven EndoBridge (WEB) device in ruptured intracranial aneurysms: a systematic review and updated meta-analysis
Background The Woven EndoBridge (WEB; Terumo) device has gained increasing recognition for treating ruptured intracranial aneurysms (RIAs) due to its ability to disrupt flow with a single implant, avoiding long-term dual antiplatelet therapy. Despite multiple studies, a comprehensive synthesis of recent evidence remains lacking. This study addresses this gap through a systematic review and meta-analysis evaluating the WEB device’s safety and efficacy in RIA management. Methods A systematic search of EMBASE, MEDLINE, Scopus, Cochrane, and the Web of Science identified studies on WEB treatment for RIAs up to January 2025. Key outcomes included implantation success, rebleeding, occlusion, retreatment, good functional outcomes (mRS 0–2) at 90 days, morbidity, mortality, and complications. A single-arm proportion analysis was conducted under a random-effects model. Results Twenty-five studies with 1,065 patients (1,077 aneurysms) were included. The implantation success rate was 98.04%, and rebleeding occurred in 0.33% of cases. Adequate and complete occlusion at 12 months were 83.77% and 59.42%, respectively. Good functional outcomes at 90 days were 87.27%, with a retreatment rate of 7.54%. Procedure-related mortality and morbidity were 0.39% and 1.39%. The overall complication rate was 12.82%, with thromboembolic and hemorrhagic events in 4.55% and 1.05% of cases, respectively. Conclusion Our findings indicate that the WEB device is a safe and effective treatment for RIAs, offering high rates of adequate occlusion, good functional outcomes, and low complication rates. This evidence reaffirms the WEB device’s safety and efficacy, supporting its wider adoption in clinical use.
- 16 June 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (7) , 1859-1872
Safety and efficacy of the Woven EndoBridge (WEB) device in ruptured intracranial aneurysms: a systematic review and updated meta-analysis
Background The Woven EndoBridge (WEB; Terumo) device has gained increasing recognition for treating ruptured intracranial aneurysms (RIAs) due to its ability to disrupt flow with a single implant, avoiding long-term dual antiplatelet therapy. Despite multiple studies, a comprehensive synthesis of recent evidence remains lacking. This study addresses this gap through a systematic review and meta-analysis evaluating the WEB device’s safety and efficacy in RIA management. Methods A systematic search of EMBASE, MEDLINE, Scopus, Cochrane, and the Web of Science identified studies on WEB treatment for RIAs up to January 2025. Key outcomes included implantation success, rebleeding, occlusion, retreatment, good functional outcomes (mRS 0–2) at 90 days, morbidity, mortality, and complications. A single-arm proportion analysis was conducted under a random-effects model. Results Twenty-five studies with 1,065 patients (1,077 aneurysms) were included. The implantation success rate was 98.04%, and rebleeding occurred in 0.33% of cases. Adequate and complete occlusion at 12 months were 83.77% and 59.42%, respectively. Good functional outcomes at 90 days were 87.27%, with a retreatment rate of 7.54%. Procedure-related mortality and morbidity were 0.39% and 1.39%. The overall complication rate was 12.82%, with thromboembolic and hemorrhagic events in 4.55% and 1.05% of cases, respectively. Conclusion Our findings indicate that the WEB device is a safe and effective treatment for RIAs, offering high rates of adequate occlusion, good functional outcomes, and low complication rates. This evidence reaffirms the WEB device’s safety and efficacy, supporting its wider adoption in clinical use.