NMNiladri Maiti

Niladri Maiti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Niladri Maiti has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative evaluation of fracture resistance of Hyflex EDM OGSF file system, Protaper Ultimate and RACE EVO file system: an in vitro study

    by N. Maiti, V. M. Lup, R. Chawla, P. Agrawal, Н. Майти, Р. Чавла

    INTRODUCTION. The intracanal fracture of nickel-titanium (NiTi) rotary instruments remains a significant procedural concern in endodontics. Advances in metallurgy, manufacturing processes, and geometric design have led to the development of new file systems with enhanced mechanical properties. The Hyflex EDM OGSF (HEDM), Protaper Ultimate (PTU), and RACE EVO (RE) systems represent distinct technological approaches to improving instrument safety. However, a direct comparative evaluation of their fracture resistance is limited. MATERIALS AND METHODS. A total of 120 new NiTi files, 40 from each system (HEDM, PTU, RE), with a tip size of 25 and a .07 taper, were selected. For the cyclic fatigue test (n = 20 per group), instruments were rotated in a custom-fabricated stainless steel artificial canal with a 60° angle of curvature and a 5 mm radius until fracture. The number of cycles to fracture (NCF) was calculated. For the torsional resistance test (n = 20 per group), the apical 3 mm of each file was clamped, and the instrument was rotated clockwise at 2 RPM until fracture, following ISO 3630-1 standards. Maximum torque (Ncm) and angular deflection (degrees) at failure were recorded. Data were statistically analyzed using one-way ANOVA and Tukey’s HSD post-hoc test (α = 0.05). RESULTS. HEDM exhibited a significantly higher mean NCF (852.5 ± 75.3) compared to both RE (621.8 ± 60.2) and PTU (455.1 ± 55.4) ( p < 0.001). RE also showed significantly higher cyclic fatigue resistance than PTU ( p < 0.001). In the torsional test, PTU demonstrated the highest maximum torque to fracture (0.46 ± 0.05 Ncm), which was significantly greater than RE (0.41 ± 0.04 Ncm) and HEDM (0.34 ± 0.06 Ncm) ( p < 0.001). The difference in torque resistance between RE and HEDM was also statistically significant ( p < 0.01). CONCLUSIONS. Within the limitations of this laboratory study, the Hyflex EDM OGSF file system demonstrated the highest resistance to cyclic fatigue. The Protaper Ultimate file system exhibited the greatest resistance to torsional fracture. The choice of instrument should be guided by the specific anatomical challenges of the root canal system.

  • Open Access

    Effect of smart endodontic motors (AI-based torque control) on file separation and dentinal damage

    by K. Dhara, A. H. Imran, N. Maiti, A. Banik, A. Arya, M. Mustafa, Н. Майти

    INTRODUCTION. Implementation of artificial intelligence (AI) in the endodontic motor technology offers improved safety due to real-time torque monitoring and adaptive control. Nevertheless, there is little comparative evidence on their clinical effectiveness in preventing instrument separation and reduction of iatrogenic dentinal damage. MATERIALS AND METHODS. Ninety human mandibular molars with mesial canals (curvature 25–35°) were randomly divided to three groups ( n = 30) Group A (AI-based smart motor with adaptive torque control), Group B (conventional motor with preset torque limits), and Group C (conventional motor with auto-reverse operation). ProTaper Next rotary files were used to prepare the standardized canals. The main variables were file separation rate and dentinal microcracks incidence evaluated through micro-computed tomography (micro-CT). Preparation time, apical transportation, canal centering ratio, and motor operational parameters were the secondary outcomes. RESULTS. Group A exhibited a much lower file separation rate (0% vs. 10.0% vs. 13.3% in Group B vs. Group C, p = 0.038) and fewer dentinal microcracks formed (16.7% vs. 43.3% vs. 50.0% p = 0.006). Group A recorded significantly lower peak of mean torque (2.1 + 0.4 Ncm compared to 2.8 + 0.6 Ncm in Group B compared to 2.9 + 0.7 Ncm in Group C, p < 0.001). Apical transportation ( p = 0.284) and canal centering ratio ( p = 0.412) showed no significant differences. Time of preparation did not differ among groups ( p = 0.156). CONCLUSIONS. Smart endodontic motors with adaptive torque control powered by AI allow a significantly lower file separation and dentinal microcrack formation than using conventional motors and offer similar shaping efficiency and preparation quality. Based on these findings, AI-based motor technology can be clinically adopted to improve the safety of the procedures.

  • Open Access

    EEG–fNIRS signal integration for motor imagery classification using deep learning and evidence theory

    by Mohammed E. Seno, Niladri Maiti, Maulik Patel, Mihirkumar M. Patel, Kalpesh B. Chaudhary, Ashish Pasaya, Babacar Toure


  • Machine Learning and Secure Image Transmission for Disease Forecasting

    by Angotu Saida, Mallareddy Adudhodla, Niladri Maiti, Krishna Murthy Inumula, G. Kalaiarasi, Lakshmi Chandrakanth Kasireddy

    The transformative potential of machine learning (ML) in disease forecasting is emphasizes how crucial secure transmission techniques are to maintaining the integrity of patient data. With the growing reliance of healthcare on sophisticated data analytics, machine learning (ML) models have become indispensable instruments for forecasting disease outbreaks and enhancing patient results. ML algorithms are able to detect patterns and trends that help with early detection and intervention in a variety of health conditions by examining large datasets that include clinical data, medical images, and environmental factors. But considering the increasing frequency of cyberattacks and data breaches in the healthcare industry, it is critical that this sensitive data be transmitted securely.


  • Telemedicine IoT Networks and Secure Image Transmission

    by A. S. Arvind, Niladri Maiti, Riddhi Chawla, Simmi Madaan, P. Sheela Rani, Mukundan Appadurai Paramashivan

    The integration of Internet of Things (IoT) networks and secure image transmission in telemedicine is investigated in this chapter, with the purpose of highlighting the significance of these two concepts in the delivery of contemporary medical care. The Internet of Things (IoT) is utilized by telemedicine in order to facilitate remote patient monitoring, improve accessibility to medical services, and enhance the efficiency of healthcare systems. Considering the growing reliance on medical imaging for accurate diagnosis, the need for secure transmission methods is of the utmost importance in order to protect sensitive patient data from being accessed by unauthorized parties and being exposed to cyber threats.


  • Role of IoT in Enhancing Secure Medical Image Transfers

    by C. Saravanakumar, Niladri Maiti, Babacar Toure, B. Vidhya, G. M. Karpura Dheepan, Joshuva Arockia Dhanraj, Aakifa Shahul

    The secure transmission of medical images is one area where the Internet of Things (IoT) is transforming the healthcare industry. The importance of IoT in improving the privacy, accuracy, and usability of medical imaging data is examined in this chapter. Healthcare providers can use IoT technologies to enable the real-time transmission of sensitive medical images while reducing the risks of unauthorized access and data breaches, thanks to the proliferation of connected devices. Effective data transfer is made possible by IoT through the use of secure and lightweight communication protocols like MQTT and CoAP.

  • Open Access

    Application of CAD-CAM in Dentistry

    by Niladri Maiti, Niva Mahapatra, Dhruvi Patel, Jeel Chanchad, Anushka Saurabhbhai Shah, Sk Mahboob Rahaman, Pratik Surana

    The application of CAD-CAM (Computer-Aided Design and Computer-Aided Manufacturing) technology has become increasingly prevalent in dentistry in recent years. Dental restorations are designed and created using CAD-CAM by enhancing the precision and efficiency. Customization of dental prostheses such as crowns, veneers, inlays, onlays and bridges is possible with CAD-CAM.