Y K Shabana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Y K Shabana has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
C B Pedersen
Department of Otorhinolaryngology, Århus University Hospital, Århus, Denmark
1 shared publicationM R Ghonim
Department of Otorhinolaryngology, Faculty of Medicine, Mansoura University, Mansoura, Egypt
1 shared publication
Latest Publications
- 1 April 1999
- Published by Wiley in Clinical Otolaryngology
- Vol. 24 (2) , 91-94
Stapedotomy: does prosthesis diameter affect outcome?
Two hundred ears with otosclerosis have been operated upon using a 0.4-mm diameter Teflon platinum piston in 100 ears and a 0.6-mm diameter Teflon piston in the other 100 ears. The postoperative air-bone gap, calculated as the difference between the postoperative air and bone conduction levels, was smaller in the 0.6 mm group for all frequencies except at 2000 Hz, the differences were statistically insignificant except at 4000 Hz. The mean postoperative air-bone gap was 8.6 dB and 7.4 dB for the 0.4 and 0.6 mm groups, respectively, which is statistically insignificant. We found no postoperative loss of bone conduction exceeding 15 dB, there was a deterioration of more than 10 dB in three ears, one in the 0.4 mm group and two in the 0.6 mm group. According to our results, we conclude that the 0.4 mm and the 0.6 mm Teflon prostheses produce the same hearing improvement in stapes surgery for otosclerosis.
- 1 April 1999
- Published by Wiley in Clinical Otolaryngology
- Vol. 24 (2) , 91-94
Stapedotomy: does prosthesis diameter affect outcome?
Two hundred ears with otosclerosis have been operated upon using a 0.4-mm diameter Teflon platinum piston in 100 ears and a 0.6-mm diameter Teflon piston in the other 100 ears. The postoperative air-bone gap, calculated as the difference between the postoperative air and bone conduction levels, was smaller in the 0.6 mm group for all frequencies except at 2000 Hz, the differences were statistically insignificant except at 4000 Hz. The mean postoperative air-bone gap was 8.6 dB and 7.4 dB for the 0.4 and 0.6 mm groups, respectively, which is statistically insignificant. We found no postoperative loss of bone conduction exceeding 15 dB, there was a deterioration of more than 10 dB in three ears, one in the 0.4 mm group and two in the 0.6 mm group. According to our results, we conclude that the 0.4 mm and the 0.6 mm Teflon prostheses produce the same hearing improvement in stapes surgery for otosclerosis.