Ahmed Alharbi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ahmed Alharbi has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Hamed Alnagran
Department of Physics, College of Science, Qassim University, Buraidah, Saudi Arabia
2 shared publications A. Caffrey
1 shared publication- A. J. Boston
University of Liverpool L69 3BX Liverpool United Kingdom
1 shared publication - A. Tolosa Delgado
European Organization for Nuclear Research
1 shared publication - Adam McCarter
University of Liverpool
1 shared publication - Adrian Montes Plaza
University of Jyväskylä
1 shared publication
Latest Publications
- 6 November 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 252
Spectroscopic characterization and isotope-specific gamma-ray mapping using a compact CsI(Tl)-SiPM OpenGamma detector
- 6 November 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 252
Spectroscopic characterization and isotope-specific gamma-ray mapping using a compact CsI(Tl)-SiPM OpenGamma detector
- Open Access
Pyrolysis-Dependent Uncollided Neutron Transmission in Date-Palm Biochar/Epoxy Composites: A GEANT4 Study with 2 MeV and Cf-252 Neutrons
Pyrolysis changes both the composition and physical structure of biochar, making it necessary to separate chemistry-driven neutron-transport effects from density and geometry effects. This computational study examines date-palm biochars produced at 300, 500, and 800 °C as fillers in an idealized epoxy matrix. The principal 2 MeV comparison used ten independent -history GEANT4 runs per material at 20 wt% filler, 5 cm thickness, and equal bulk density (1.25 g cm−3). From BC300 to BC800, total forward track-length fluence increased by only 0.30%, whereas the fluence-weighted response increased by 2.86%. A separate ten-replicate component campaign confirmed that the 2 MeV BC800–BC300 difference ( pSv primary−1) was driven by increased uncollided-primary transmission ( pSv primary−1), while the collided-primary contribution decreased slightly ( pSv primary−1). For a representative 252Cf Watt spectrum, increased by 2.98%, with 91.1% of the net increase arising from uncollided primaries. A cm2 full-face geometry increased scattered buildup, yet 84.0% of the BC800–BC300 increase remained attributable to uncollided primaries. Additional density, thickness, and loading sensitivities gave positive BC800–BC300 contrasts under all tested conditions (1.18–8.24%), although the integral-fluence contrast was not universally positive. The model therefore supports a robust chemistry-related increase in high-energy primary survival while showing that the scattered-field partition and engineering performance remain geometry- and processing-dependent.Open AccessPyrolysis-Dependent Uncollided Neutron Transmission in Date-Palm Biochar/Epoxy Composites: A GEANT4 Study with 2 MeV and Cf-252 Neutrons
Pyrolysis changes both the composition and physical structure of biochar, making it necessary to separate chemistry-driven neutron-transport effects from density and geometry effects. This computational study examines date-palm biochars produced at 300, 500, and 800 °C as fillers in an idealized epoxy matrix. The principal 2 MeV comparison used ten independent -history GEANT4 runs per material at 20 wt% filler, 5 cm thickness, and equal bulk density (1.25 g cm−3). From BC300 to BC800, total forward track-length fluence increased by only 0.30%, whereas the fluence-weighted response increased by 2.86%. A separate ten-replicate component campaign confirmed that the 2 MeV BC800–BC300 difference ( pSv primary−1) was driven by increased uncollided-primary transmission ( pSv primary−1), while the collided-primary contribution decreased slightly ( pSv primary−1). For a representative 252Cf Watt spectrum, increased by 2.98%, with 91.1% of the net increase arising from uncollided primaries. A cm2 full-face geometry increased scattered buildup, yet 84.0% of the BC800–BC300 increase remained attributable to uncollided primaries. Additional density, thickness, and loading sensitivities gave positive BC800–BC300 contrasts under all tested conditions (1.18–8.24%), although the integral-fluence contrast was not universally positive. The model therefore supports a robust chemistry-related increase in high-energy primary survival while showing that the scattered-field partition and engineering performance remain geometry- and processing-dependent. - Open Access
Deformation-Aware Monte Carlo Assessment of a Bi2O3/Thermoplastic Polyurethane Shielding Surrogate Under Tensile Strain and Local Thickness Loss
Flexible shielding polymers may undergo geometric thinning during tensile use or localized damage, but flat-sheet attenuation measurements cannot resolve the resulting spatial loss of protection. A radiation-transport surrogate comprising 60 wt% thermoplastic polyurethane and 40 wt% (modeled density, 1.835 g ) was investigated using prescribed deformation, Geant4, PHITS, Phy-X/XCOM, and 60–120 kVp SpekPy spectra. This is a computational transport model, not a mechanically or experimentally validated formulation. Geant4 mass attenuation coefficients were verified against Phy-X at six energies (30–100 keV) and against XCOM at 90, 91, 92, and 95 keV across the Bi K-edge. Constant-volume uniform strain of 50% raised whole-field transmission by 14.8–32.8%; an illustrative transverse-response sensitivity quantified the dependence of thickness and attenuation on the prescribed kinematics. At 50% local thinning, whole-field transmission increased by only 5.66–15.0%, whereas 5-million-history event-based ROI scoring gave dose enhancement factors of , , , and at 60, 80, 100, and 120 kVp, respectively. Additional 60 kVp calculations varied the defect dimensions, ROI size, and detector position, revealing the influence of spatial averaging. Beer–Lambert attenuation accounts for the primary response to prescribed uniform thinning; the Monte Carlo framework additionally resolves polychromatic scatter, spectral changes, and localized dose enhancement. These numerical results characterize idealized geometric perturbations and should not be interpreted as measurements of real garment durability or clinical dose.Open AccessDeformation-Aware Monte Carlo Assessment of a Bi2O3/Thermoplastic Polyurethane Shielding Surrogate Under Tensile Strain and Local Thickness Loss
Flexible shielding polymers may undergo geometric thinning during tensile use or localized damage, but flat-sheet attenuation measurements cannot resolve the resulting spatial loss of protection. A radiation-transport surrogate comprising 60 wt% thermoplastic polyurethane and 40 wt% (modeled density, 1.835 g ) was investigated using prescribed deformation, Geant4, PHITS, Phy-X/XCOM, and 60–120 kVp SpekPy spectra. This is a computational transport model, not a mechanically or experimentally validated formulation. Geant4 mass attenuation coefficients were verified against Phy-X at six energies (30–100 keV) and against XCOM at 90, 91, 92, and 95 keV across the Bi K-edge. Constant-volume uniform strain of 50% raised whole-field transmission by 14.8–32.8%; an illustrative transverse-response sensitivity quantified the dependence of thickness and attenuation on the prescribed kinematics. At 50% local thinning, whole-field transmission increased by only 5.66–15.0%, whereas 5-million-history event-based ROI scoring gave dose enhancement factors of , , , and at 60, 80, 100, and 120 kVp, respectively. Additional 60 kVp calculations varied the defect dimensions, ROI size, and detector position, revealing the influence of spatial averaging. Beer–Lambert attenuation accounts for the primary response to prescribed uniform thinning; the Monte Carlo framework additionally resolves polychromatic scatter, spectral changes, and localized dose enhancement. These numerical results characterize idealized geometric perturbations and should not be interpreted as measurements of real garment durability or clinical dose. - Open Access
Influence of High-Z Filler Chemistry on the Energy-Dependent Gamma-Ray Shielding of Cement-Board Composites
Cement-board composites were prepared at a fixed nominal filler loading to compare the attenuation response of different high-Z additives under a common mass-fraction condition. A commercial cement board was used as the host matrix, and five formulations containing 30 wt% Bi2O3, BaSO4, HfO2, WO3, or Fe were fabricated and compared with a pure pressed control. X-ray diffraction (XRD) was used to examine phase-related structural features, while gamma-ray transmission was measured with 241Am (59.5 keV) and 137Cs (661.7 keV) using a collimated NaI(Tl) spectrometric arrangement. At 59.5 keV, the linear attenuation coefficient increased from 0.3909 cm−1 for the control to 0.6423, 1.8127, 2.5464, 2.6205, and 2.7828 cm−1 for Fe-, HfO2-, WO3-, BaSO4-, and Bi2O3-containing specimens, respectively. The corresponding half-value layer decreased from 1.773 cm to 1.079, 0.382, 0.272, 0.265, and 0.249 cm. At 661.7 keV, the modified specimens remained more attenuating than the control but clustered within 0.1731–0.1842 cm−1. Within the tested conditions, the fabricated formulations showed much stronger discrimination at 59.5 keV than at 661.7 keV, with Bi2O3-, BaSO4-, and WO3-containing specimens forming the strongest low-energy group. Because the pressed-disc densities differed between the formulations, these linear-attenuation differences are interpreted as the combined response of additive identity and the resulting bulk density/compaction rather than as a chemistry-only effect. This study is a fixed-loading, two-energy screening comparison rather than a concentration or structural optimization study.
Open AccessInfluence of High-Z Filler Chemistry on the Energy-Dependent Gamma-Ray Shielding of Cement-Board Composites
Cement-board composites were prepared at a fixed nominal filler loading to compare the attenuation response of different high-Z additives under a common mass-fraction condition. A commercial cement board was used as the host matrix, and five formulations containing 30 wt% Bi2O3, BaSO4, HfO2, WO3, or Fe were fabricated and compared with a pure pressed control. X-ray diffraction (XRD) was used to examine phase-related structural features, while gamma-ray transmission was measured with 241Am (59.5 keV) and 137Cs (661.7 keV) using a collimated NaI(Tl) spectrometric arrangement. At 59.5 keV, the linear attenuation coefficient increased from 0.3909 cm−1 for the control to 0.6423, 1.8127, 2.5464, 2.6205, and 2.7828 cm−1 for Fe-, HfO2-, WO3-, BaSO4-, and Bi2O3-containing specimens, respectively. The corresponding half-value layer decreased from 1.773 cm to 1.079, 0.382, 0.272, 0.265, and 0.249 cm. At 661.7 keV, the modified specimens remained more attenuating than the control but clustered within 0.1731–0.1842 cm−1. Within the tested conditions, the fabricated formulations showed much stronger discrimination at 59.5 keV than at 661.7 keV, with Bi2O3-, BaSO4-, and WO3-containing specimens forming the strongest low-energy group. Because the pressed-disc densities differed between the formulations, these linear-attenuation differences are interpreted as the combined response of additive identity and the resulting bulk density/compaction rather than as a chemistry-only effect. This study is a fixed-loading, two-energy screening comparison rather than a concentration or structural optimization study.
- Open Access
- 22 June 2026
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 19 (3)
Low-dose Gamma-ray dosimetry using PVA–NBT composite films reinforced with high-Z oxides and graphene nanoplatelets
- 22 June 2026
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 19 (3)
Open AccessLow-dose Gamma-ray dosimetry using PVA–NBT composite films reinforced with high-Z oxides and graphene nanoplatelets
- 20 April 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 246
Simulation-based performance evaluation of a planar segmented HPGe detector for single-detector Compton imaging
- 20 April 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 246
Simulation-based performance evaluation of a planar segmented HPGe detector for single-detector Compton imaging
- Open Access
Gamma-Ray Attenuation Performance of PEEK Reinforced with Natural Pumice and Palygorskite
Lightweight, lead-free polymer–mineral composites have attracted increasing interest as radiation-attenuating materials for applications where reduced mass and environmental compatibility are required. In this work, the -ray attenuation behavior of poly(ether ether ketone) (PEEK) reinforced with natural palygorskite and pumice was evaluated at filler concentrations of 10–40 wt%. Photon interaction parameters, including the linear attenuation coefficient (), half-value layer (HVL), mean free path (), and effective atomic number (), were computed over the energy range 15 keV–15 MeV using the Phy-X/PSD platform and validated through full Geant4 Monte Carlo transmission simulations. At 15 keV, increased from for pure PEEK to and for the 40 wt% palygorskite- and pumice-filled composites, respectively, reducing the HVL from 0.69 cm to 0.24 cm and 0.11 cm. The corresponding values increased from 6.5 (pure PEEK) to 9.4 (40 wt% palygorskite) and 15.3 (40 wt% pumice), reflecting the influence of higher-Z oxide constituents in pumice. At higher photon energies, the attenuation curves converged as Compton scattering became dominant, although pumice-filled PEEK retained marginally higher and shorter up to the MeV region. These findings demonstrate that natural mineral fillers can enhance the photon attenuation behavior of PEEK while retaining the known thermal stability and mechanical performance of the polymer matrix as reported in the literature, indicating their potential use as lightweight, secondary radiation-attenuating components in medical, industrial, and aerospace applications.Open AccessGamma-Ray Attenuation Performance of PEEK Reinforced with Natural Pumice and Palygorskite
Lightweight, lead-free polymer–mineral composites have attracted increasing interest as radiation-attenuating materials for applications where reduced mass and environmental compatibility are required. In this work, the -ray attenuation behavior of poly(ether ether ketone) (PEEK) reinforced with natural palygorskite and pumice was evaluated at filler concentrations of 10–40 wt%. Photon interaction parameters, including the linear attenuation coefficient (), half-value layer (HVL), mean free path (), and effective atomic number (), were computed over the energy range 15 keV–15 MeV using the Phy-X/PSD platform and validated through full Geant4 Monte Carlo transmission simulations. At 15 keV, increased from for pure PEEK to and for the 40 wt% palygorskite- and pumice-filled composites, respectively, reducing the HVL from 0.69 cm to 0.24 cm and 0.11 cm. The corresponding values increased from 6.5 (pure PEEK) to 9.4 (40 wt% palygorskite) and 15.3 (40 wt% pumice), reflecting the influence of higher-Z oxide constituents in pumice. At higher photon energies, the attenuation curves converged as Compton scattering became dominant, although pumice-filled PEEK retained marginally higher and shorter up to the MeV region. These findings demonstrate that natural mineral fillers can enhance the photon attenuation behavior of PEEK while retaining the known thermal stability and mechanical performance of the polymer matrix as reported in the literature, indicating their potential use as lightweight, secondary radiation-attenuating components in medical, industrial, and aerospace applications. - Top Cited PapersOpen Access
Hybrid Phy-X/PSD–Geant4 Assessment of Gamma and Neutron Shielding in Lead-Free HDPE Composites Reinforced with High-Z Oxides
This study evaluates lead-free high-density polyethylene (HDPE) composites reinforced with high-Z oxides (Bi2O3, WO3, Gd2O3, TeO2, and a Bi2O3/WO3 hybrid) as lightweight materials for gamma-ray and fast-neutron shielding. A hybrid computational framework combining Phy-X/PSD with Geant4 Monte Carlo simulations was used to obtain key shielding parameters, including the linear and mass attenuation coefficients (μ, μ/ρ), half-value layer (HVL), mean free path (MFP), effective atomic number (Zeff), effective electron density (Neff), exposure and energy-absorption buildup factors (EBF, EABF), and fast-neutron removal cross section (ΣR). The incorporation of heavy oxides produced a pronounced improvement in gamma-ray attenuation, particularly at low energies, where the linear attenuation coefficient increased from below 1 cm−1 for neat HDPE to values exceeding 130–150 cm−1 for Bi- and W-rich composites. In the intermediate Compton-scattering region (≈0.3–1 MeV), all oxide-reinforced systems maintained a clear attenuation advantage, with μ values around 0.12–0.13 cm−1 compared with ≈0.07 cm−1 for pure HDPE. At higher photon energies, the dense composites continued to outperform the polymer matrix, yielding μ values of approximately 0.07–0.09 cm−1 versus ≈0.02 cm−1 for HDPE due to enhanced pair-production interactions. The Bi2O3/WO3 hybrid composite exhibited attenuation behavior comparable, and in some regions slightly exceeding, that of the single-oxide systems, indicating that mixed fillers can effectively balance density and shielding efficiency. Oxide addition significantly reduced exposure and energy-absorption buildup factors below 1 MeV, with a moderate increase at higher energies associated with secondary radiation processes. Fast-neutron removal cross sections were also modestly enhanced, with Gd2O3-containing composites showing the highest values due to the combined effects of hydrogen moderation and neutron capture. The close agreement between Phy-X/PSD and Geant4 results confirms the reliability of the dual-method approach. Overall, HDPE composites containing about 60 wt.% oxide filler offer a practical compromise between shielding performance, manufacturability, and environmental safety, making them promising candidates for medical, nuclear, and aerospace radiation-protection applications.
Top Cited PapersOpen AccessHybrid Phy-X/PSD–Geant4 Assessment of Gamma and Neutron Shielding in Lead-Free HDPE Composites Reinforced with High-Z Oxides
This study evaluates lead-free high-density polyethylene (HDPE) composites reinforced with high-Z oxides (Bi2O3, WO3, Gd2O3, TeO2, and a Bi2O3/WO3 hybrid) as lightweight materials for gamma-ray and fast-neutron shielding. A hybrid computational framework combining Phy-X/PSD with Geant4 Monte Carlo simulations was used to obtain key shielding parameters, including the linear and mass attenuation coefficients (μ, μ/ρ), half-value layer (HVL), mean free path (MFP), effective atomic number (Zeff), effective electron density (Neff), exposure and energy-absorption buildup factors (EBF, EABF), and fast-neutron removal cross section (ΣR). The incorporation of heavy oxides produced a pronounced improvement in gamma-ray attenuation, particularly at low energies, where the linear attenuation coefficient increased from below 1 cm−1 for neat HDPE to values exceeding 130–150 cm−1 for Bi- and W-rich composites. In the intermediate Compton-scattering region (≈0.3–1 MeV), all oxide-reinforced systems maintained a clear attenuation advantage, with μ values around 0.12–0.13 cm−1 compared with ≈0.07 cm−1 for pure HDPE. At higher photon energies, the dense composites continued to outperform the polymer matrix, yielding μ values of approximately 0.07–0.09 cm−1 versus ≈0.02 cm−1 for HDPE due to enhanced pair-production interactions. The Bi2O3/WO3 hybrid composite exhibited attenuation behavior comparable, and in some regions slightly exceeding, that of the single-oxide systems, indicating that mixed fillers can effectively balance density and shielding efficiency. Oxide addition significantly reduced exposure and energy-absorption buildup factors below 1 MeV, with a moderate increase at higher energies associated with secondary radiation processes. Fast-neutron removal cross sections were also modestly enhanced, with Gd2O3-containing composites showing the highest values due to the combined effects of hydrogen moderation and neutron capture. The close agreement between Phy-X/PSD and Geant4 results confirms the reliability of the dual-method approach. Overall, HDPE composites containing about 60 wt.% oxide filler offer a practical compromise between shielding performance, manufacturability, and environmental safety, making them promising candidates for medical, nuclear, and aerospace radiation-protection applications.