Wouter J. H. Veldkamp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wouter J. H. Veldkamp has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Ramona W. Bouwman
Dutch Reference Centre for Screening (LRCB), Radboud University Medical Centre, The Netherlands
2 shared publications - Ruben van Engen
Dutch Reference Centre for Screening (LRCB), Wijchenseweg 101, 6538 SW Nijmegen, The Netherlands
2 shared publications A. Calzado Cantera
Departamento de Radiología, Universidad Complutense de Madrid, Madrid, Spain
1 shared publication- Adriaan A. Lammertsma
University Medical Center Groningen, University of Groningen
1 shared publication - Arie Johannes van Lange
Department of Radiology, Leiden University Medical Center, Leiden, Kingdom of the Netherlands
1 shared publication Christiana Balta
Radboud Univ. Medical Ctr. (Netherlands)
1 shared publication
Latest Publications
- Open Access
- 19 June 2025
- Published by Springer Nature in EJNMMI Physics
- Vol. 12 (1) , 1-18
PET/CT acquisition and processing protocols in the Netherlands
To evaluate variations in acquisition and processing protocols for four of the most common PET/CT examinations in Dutch hospitals: FDG-WB, [18F]F-PSMA, [68Ga]Ga-PSMA, and FDG-Brain. All nuclear medicine departments in the Netherlands with a PET/CT scanner were invited to participate in a survey about acquisition and processing protocols for FDG-WB, [18F]F-PSMA, [68Ga]Ga-PSMA, and FDG-Brain PET/CT examinations. The survey collected data on injected activity, acquisition times, and reconstruction/post-processing settings. From these data, we analyzed the weight-dependent injected activity, acquisition count statistics, and correlations with scanner performance (NEMA sensitivity). A total of 42 hospitals responded (including all Dutch University Medical Centers), providing data from 58 PET/CT systems spanning 11 different models from 4 vendors. Injected activity and scan duration varied widely across hospitals, even for the same scanner model and examination type. A moderate negative correlation was observed between scanner sensitivity and the normalized injected activity × scan duration product for FDG-WB (R2 = 0.50, slope = − 186.5) and FDG-brain (R2 = 0.33, slope = − 180.8), suggesting that hospitals using higher-sensitivity scanners tend to reduce either injected activity or scan duration to maintain comparable acquisition counts. For [18F]F-PSMA (R2 = 0.24, slope = − 62.6), the trend was less pronounced, indicating greater variability in how PET/CT centers adjust injected activity and scan duration for these tracers. In contrast, for [68 Ga]Ga-PSMA (R2 = 0.04, slope = − 28.3), no significant correlation was found, suggesting that scanner sensitivity plays a minimal role in protocol selection for these examinations. The observed variations in injected activity led to differences in patient radiation dose by a factor of 4 for FDG-WB, more than a factor of 10 for PSMA, and a factor of 5 for FDG-brain scans. These differences persist even after accounting for scan duration, scanner sensitivity, and overlap between scanning positions, highlighting substantial inconsistencies in PET/CT imaging protocols across Dutch hospitals. The main objective of this survey was to determine the current state of practice in the Netherlands for three common PET/CT examinations. We observed variations in the injected activity for all PET/CT exam types, even within the same scanner model, that cannot be explained by taking into account differences in scanning times or uptake times. The direct implication of the observed variation in injected activity is a similar variation in radiation dose to the patient. We observed differences in dose to the patient of up to a factor 4 for FDG-WB, more than a factor of 5for [18F]F-PSMA, a factor of 4 for [68 Ga]Ga-PSMA, and up to a factor of 5 for FDG-brain scans. Variations in count statistics, reconstruction, and processing settings for similar-weight patients on comparable PET/CT systems should be further investigated for their impact on lesion detectability.
- 19 June 2025
- Published by Springer Nature in EJNMMI Physics
- Vol. 12 (1) , 1-18
Open AccessPET/CT acquisition and processing protocols in the Netherlands
To evaluate variations in acquisition and processing protocols for four of the most common PET/CT examinations in Dutch hospitals: FDG-WB, [18F]F-PSMA, [68Ga]Ga-PSMA, and FDG-Brain. All nuclear medicine departments in the Netherlands with a PET/CT scanner were invited to participate in a survey about acquisition and processing protocols for FDG-WB, [18F]F-PSMA, [68Ga]Ga-PSMA, and FDG-Brain PET/CT examinations. The survey collected data on injected activity, acquisition times, and reconstruction/post-processing settings. From these data, we analyzed the weight-dependent injected activity, acquisition count statistics, and correlations with scanner performance (NEMA sensitivity). A total of 42 hospitals responded (including all Dutch University Medical Centers), providing data from 58 PET/CT systems spanning 11 different models from 4 vendors. Injected activity and scan duration varied widely across hospitals, even for the same scanner model and examination type. A moderate negative correlation was observed between scanner sensitivity and the normalized injected activity × scan duration product for FDG-WB (R2 = 0.50, slope = − 186.5) and FDG-brain (R2 = 0.33, slope = − 180.8), suggesting that hospitals using higher-sensitivity scanners tend to reduce either injected activity or scan duration to maintain comparable acquisition counts. For [18F]F-PSMA (R2 = 0.24, slope = − 62.6), the trend was less pronounced, indicating greater variability in how PET/CT centers adjust injected activity and scan duration for these tracers. In contrast, for [68 Ga]Ga-PSMA (R2 = 0.04, slope = − 28.3), no significant correlation was found, suggesting that scanner sensitivity plays a minimal role in protocol selection for these examinations. The observed variations in injected activity led to differences in patient radiation dose by a factor of 4 for FDG-WB, more than a factor of 10 for PSMA, and a factor of 5 for FDG-brain scans. These differences persist even after accounting for scan duration, scanner sensitivity, and overlap between scanning positions, highlighting substantial inconsistencies in PET/CT imaging protocols across Dutch hospitals. The main objective of this survey was to determine the current state of practice in the Netherlands for three common PET/CT examinations. We observed variations in the injected activity for all PET/CT exam types, even within the same scanner model, that cannot be explained by taking into account differences in scanning times or uptake times. The direct implication of the observed variation in injected activity is a similar variation in radiation dose to the patient. We observed differences in dose to the patient of up to a factor 4 for FDG-WB, more than a factor of 5for [18F]F-PSMA, a factor of 4 for [68 Ga]Ga-PSMA, and up to a factor of 5 for FDG-brain scans. Variations in count statistics, reconstruction, and processing settings for similar-weight patients on comparable PET/CT systems should be further investigated for their impact on lesion detectability.
- 10 March 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10136, 101360M-101360M-9
Signal template generation from acquired mammographic images for the non-prewhitening model observer with eye-filter
- 10 March 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10136, 101360M-101360M-9
Signal template generation from acquired mammographic images for the non-prewhitening model observer with eye-filter
- 1 January 2014
- Published by Springer Nature
- p. 715-722
Evaluation of Human Contrast Sensitivity Functions Used in the Nonprewhitening Model Observer with Eye Filter
- 1 January 2014
- Published by Springer Nature
- p. 715-722
Evaluation of Human Contrast Sensitivity Functions Used in the Nonprewhitening Model Observer with Eye Filter
- 1 August 2008
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 173 (1) , 83-90
Automated analysis of secretory vesicle distribution at the ultrastructural level
- 1 August 2008
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 173 (1) , 83-90
Automated analysis of secretory vesicle distribution at the ultrastructural level
- 24 October 2006
- Published by Springer Nature in European Radiology
- Vol. 17 (7) , 1795-1805
An inter-hospital comparison of patient dose based on clinical indications
Patient dose is usually estimated for a single radiographic projection or computed tomography (CT) series. In this study, patient dose was calculated for predefined clinical indications (24 radiography, 11 CT). Members of the radiology staff of each of 11 hospitals were trained in dose measurement and calculation techniques. Based on clinical indications participants decided on imaging protocols and calculated cumulative effective dose for a complete examination. Effective dose ranged from <1 μSv to 0.6 mSv for examinations with radiographs and from 0.2 to 12 mSv for CT scans. Differences in the imaging protocols contributedd to a substantial variation in patient dose. For mammography, average glandular dose (AGD) was estimated for 32-, 53- and 90-mm compressed breast thicknesses, with a median value of 0.74, 1.74 and 3.40 mGy, respectively. The results presented here demonstrate that a pragmatic choice of dosimetry methods enables local staff to estimate effective dose. The inclusion of imaging protocols in the dose surveys provided a broader view on the variations in patient dose between hospitals.
- 24 October 2006
- Published by Springer Nature in European Radiology
- Vol. 17 (7) , 1795-1805
An inter-hospital comparison of patient dose based on clinical indications
Patient dose is usually estimated for a single radiographic projection or computed tomography (CT) series. In this study, patient dose was calculated for predefined clinical indications (24 radiography, 11 CT). Members of the radiology staff of each of 11 hospitals were trained in dose measurement and calculation techniques. Based on clinical indications participants decided on imaging protocols and calculated cumulative effective dose for a complete examination. Effective dose ranged from <1 μSv to 0.6 mSv for examinations with radiographs and from 0.2 to 12 mSv for CT scans. Differences in the imaging protocols contributedd to a substantial variation in patient dose. For mammography, average glandular dose (AGD) was estimated for 32-, 53- and 90-mm compressed breast thicknesses, with a median value of 0.74, 1.74 and 3.40 mGy, respectively. The results presented here demonstrate that a pragmatic choice of dosimetry methods enables local staff to estimate effective dose. The inclusion of imaging protocols in the dose surveys provided a broader view on the variations in patient dose between hospitals.
- 8 April 2006
- Published by Springer Nature in European Radiology
- Vol. 16 (10) , 2334-2340
Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality
This study aimed at assessment of efficacy of selective in-plane shielding in adults by quantitative evaluation of the achieved dose reduction and image quality. Commercially available accessories for in-plane shielding of the eye lens, thyroid and breast, and an anthropomorphic phantom were used for the evaluation of absorbed dose and image quality. Organ dose and total energy imparted were assessed by means of a Monte Carlo technique taking into account tube voltage, tube current, and scanner type. Image quality was quantified as noise in soft tissue. Application of the lens shield reduced dose to the lens by 27% and to the brain by 1%. The thyroid shield reduced thyroid dose by 26%; the breast shield reduced dose to the breasts by 30% and to the lungs by 15%. Total energy imparted (unshielded/shielded) was 88/86 mJ for computed tomography (CT) brain, 64/60 mJ for CT cervical spine, and 289/260 mJ for CT chest scanning. An increase in image noise could be observed in the ranges were bismuth shielding was applied. The observed reduction of organ dose and total energy imparted could be achieved more efficiently by a reduction of tube current. The application of in-plane selective shielding is therefore discouraged.
- 8 April 2006
- Published by Springer Nature in European Radiology
- Vol. 16 (10) , 2334-2340
Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality
This study aimed at assessment of efficacy of selective in-plane shielding in adults by quantitative evaluation of the achieved dose reduction and image quality. Commercially available accessories for in-plane shielding of the eye lens, thyroid and breast, and an anthropomorphic phantom were used for the evaluation of absorbed dose and image quality. Organ dose and total energy imparted were assessed by means of a Monte Carlo technique taking into account tube voltage, tube current, and scanner type. Image quality was quantified as noise in soft tissue. Application of the lens shield reduced dose to the lens by 27% and to the brain by 1%. The thyroid shield reduced thyroid dose by 26%; the breast shield reduced dose to the breasts by 30% and to the lungs by 15%. Total energy imparted (unshielded/shielded) was 88/86 mJ for computed tomography (CT) brain, 64/60 mJ for CT cervical spine, and 289/260 mJ for CT chest scanning. An increase in image noise could be observed in the ranges were bismuth shielding was applied. The observed reduction of organ dose and total energy imparted could be achieved more efficiently by a reduction of tube current. The application of in-plane selective shielding is therefore discouraged.