Kim-Anh Nguyen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kim-Anh Nguyen has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Ba Tu Phung
The University of Danang - University of Science and Technology,Faculty of Electrical Engineering,Da Nang,Vietnam
5 shared publications - Huy Hoang Le
PowerMore Ltd
5 shared publications Huy Vu Tran
Faculty of Electrical Engineering, The University of Danang – University of Science and Technology, Danang, Vietnam
4 shared publications- Thai Anh Au Tran
University of Science and Technology, The University of Danang
4 shared publications Huy Hoang Le
3 shared publications- Xuan Khanh Ho
University of Science and Technology, The University of Danang
3 shared publications
Latest Publications
- Open Access
- 7 October 2026
- Published by Elsevier in SSRN Electronic Journal
A Cumulative Fisher-Information Framework for the Timing of Health-Indicator Information in Prognostics
A health indicator fixes what any remaining-useful-life model can achieve, yet indicators are compared through a fitted model’s accuracy, confounding the two. This paper develops an indicator-level Fisher-information framework, free of parametric degradation families, whose estimand is the unit’s position on its damage clock instead of the remaining life. Fixed by the observation model the indicator induces, this information sets a Cramér–Rao floor for every unbiased estimate under a known trend and noise law. The accumulated information forms one non-decreasing curve whose quantile, increment and value give the earliest age at which a stated precision is reachable, the shortest window reaching it, and what truncation retains. Three corrections for real residuals are derived in closed form, and an identity gives the effect of a curve error. A record’s estimated curve is summarised by the age by which a fixed fraction of its information has arrived. Across 370 run-to-failure records, the floor is attained to within 9% on bearings and both turbofan fleets but not on cells. On two bearing rigs, indicators normalising the spectrum to a distribution reach that fraction well before absolute-amplitude ones. This result replicates without a spectrum and persists under a causal estimator only on the longer-record rig. The ordering concerns timing only; the amplitude indicators carry 4to 19 times the information.
- 7 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Cumulative Fisher-Information Framework for the Timing of Health-Indicator Information in Prognostics
A health indicator fixes what any remaining-useful-life model can achieve, yet indicators are compared through a fitted model’s accuracy, confounding the two. This paper develops an indicator-level Fisher-information framework, free of parametric degradation families, whose estimand is the unit’s position on its damage clock instead of the remaining life. Fixed by the observation model the indicator induces, this information sets a Cramér–Rao floor for every unbiased estimate under a known trend and noise law. The accumulated information forms one non-decreasing curve whose quantile, increment and value give the earliest age at which a stated precision is reachable, the shortest window reaching it, and what truncation retains. Three corrections for real residuals are derived in closed form, and an identity gives the effect of a curve error. A record’s estimated curve is summarised by the age by which a fixed fraction of its information has arrived. Across 370 run-to-failure records, the floor is attained to within 9% on bearings and both turbofan fleets but not on cells. On two bearing rigs, indicators normalising the spectrum to a distribution reach that fraction well before absolute-amplitude ones. This result replicates without a spectrum and persists under a causal estimator only on the longer-record rig. The ordering concerns timing only; the amplitude indicators carry 4to 19 times the information.
- Open Access
- 2 August 2026
- Published by Elsevier in Engineering Science and Technology, an International Journal
- Vol. 81
Information-theoretic limits of health indicator construction for remaining useful life prediction
- 2 August 2026
- Published by Elsevier in Engineering Science and Technology, an International Journal
- Vol. 81
Open AccessInformation-theoretic limits of health indicator construction for remaining useful life prediction
- 1 August 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (15) , 155314
A high step-up DC–DC converter with voltage multiplier cell for renewable energy systems
This paper proposes a novel high step-up DC–DC converter topology featuring two synchronously controlled power switches driven by identical gate signals, thereby simplifying the control circuit. The proposed converter (PC) employs an input inductor to ensure continuous input current and a three-winding coupled inductor to achieve ultra-high voltage conversion gain. In addition, a voltage-multiplier cell is incorporated to further enhance the output voltage gain (VG). A passive-clamp circuit is utilized to recycle leakage energy, reduce voltage spikes, and improve overall efficiency. The converter is analyzed under both continuous conduction mode (CCM) and discontinuous conduction mode (DCM), including the derivation of VG characteristics and CCM/DCM boundary conditions. A comprehensive theoretical investigation is presented, covering steady-state operation, VG, voltage and current stresses of semiconductor devices, component design considerations, power-loss analysis, small-signal modeling, control design, and dynamic response characteristics. Compared with recently reported high step-up converters, the proposed topology achieves an improved trade-off among VG, switch stress, magnetic complexity, and component count through the coordinated integration of the coupled-inductor structure, voltage-multiplier cell, and passive-clamp circuit. To validate the theoretical analysis, a 200 W laboratory prototype with a 24 V input and 400 V output was designed and implemented in both simulation and hardware. Experimental results demonstrate a peak efficiency of 96.7% at 40% load and 95.7% at full load, confirming high efficiency over a wide operating range. These results verify the effectiveness and suitability of the PC for renewable-energy and high step-up power-conversion applications.
- 1 August 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (15) , 155314
A high step-up DC–DC converter with voltage multiplier cell for renewable energy systems
This paper proposes a novel high step-up DC–DC converter topology featuring two synchronously controlled power switches driven by identical gate signals, thereby simplifying the control circuit. The proposed converter (PC) employs an input inductor to ensure continuous input current and a three-winding coupled inductor to achieve ultra-high voltage conversion gain. In addition, a voltage-multiplier cell is incorporated to further enhance the output voltage gain (VG). A passive-clamp circuit is utilized to recycle leakage energy, reduce voltage spikes, and improve overall efficiency. The converter is analyzed under both continuous conduction mode (CCM) and discontinuous conduction mode (DCM), including the derivation of VG characteristics and CCM/DCM boundary conditions. A comprehensive theoretical investigation is presented, covering steady-state operation, VG, voltage and current stresses of semiconductor devices, component design considerations, power-loss analysis, small-signal modeling, control design, and dynamic response characteristics. Compared with recently reported high step-up converters, the proposed topology achieves an improved trade-off among VG, switch stress, magnetic complexity, and component count through the coordinated integration of the coupled-inductor structure, voltage-multiplier cell, and passive-clamp circuit. To validate the theoretical analysis, a 200 W laboratory prototype with a 24 V input and 400 V output was designed and implemented in both simulation and hardware. Experimental results demonstrate a peak efficiency of 96.7% at 40% load and 95.7% at full load, confirming high efficiency over a wide operating range. These results verify the effectiveness and suitability of the PC for renewable-energy and high step-up power-conversion applications.
- Open Access
- 27 May 2026
- Published by Hanoi University of Science and Technology in Smart Systems and Devices
- Vol. 36 (3) , 038-047
Thermal Effects of Harmonics on Distribution Transformers: A Coupled Electromagnetic–Thermal Finite-Element-Based Approach
The growing demand for electrical energy, together with increasingly complex operating conditions caused by nonlinear loads and the widespread integration of renewable energy sources, has led to increased harmonic distortion in power systems. As critical assets in distribution networks, transformers are particularly vulnerable to harmonic-induced losses and thermal stress, which can accelerate insulation aging and reduce service life. This study investigates the thermal effects of harmonics on a medium-voltage distribution transformer using a coupled electromagnetic–thermal approach based on the finite element method. In the proposed workflow, ANSYS Maxwell is used to compute electromagnetic quantities and harmonic-dependent losses, and these losses are then used as inputs to an equivalent electro-thermal model to predict top-oil and winding hot-spot temperatures. The electromagnetic model is validated under no-load and short-circuit conditions, and simulations are conducted for linear and nonlinear loads at 50%, 100%, and 125% of rated load. The hybrid thermal prediction results show good agreement with detailed ANSYS Mechanical simulations, with a deviation of approximately 3% in the linear-load case and 0.016% in the nonlinear-load case. The results show that harmonic loading significantly increases load-related losses and hot-spot temperature, while also revealing a non-uniform temperature distribution that enables hot-spot localization. The obtained spatial hot-spot information supports insulation loss-of-life assessment and provides practical guidance for design improvement, sensor placement, periodic inspection/testing, spare-part planning, and condition-based maintenance under harmonic operating conditions.
- 27 May 2026
- Published by Hanoi University of Science and Technology in Smart Systems and Devices
- Vol. 36 (3) , 038-047
Open AccessThermal Effects of Harmonics on Distribution Transformers: A Coupled Electromagnetic–Thermal Finite-Element-Based Approach
The growing demand for electrical energy, together with increasingly complex operating conditions caused by nonlinear loads and the widespread integration of renewable energy sources, has led to increased harmonic distortion in power systems. As critical assets in distribution networks, transformers are particularly vulnerable to harmonic-induced losses and thermal stress, which can accelerate insulation aging and reduce service life. This study investigates the thermal effects of harmonics on a medium-voltage distribution transformer using a coupled electromagnetic–thermal approach based on the finite element method. In the proposed workflow, ANSYS Maxwell is used to compute electromagnetic quantities and harmonic-dependent losses, and these losses are then used as inputs to an equivalent electro-thermal model to predict top-oil and winding hot-spot temperatures. The electromagnetic model is validated under no-load and short-circuit conditions, and simulations are conducted for linear and nonlinear loads at 50%, 100%, and 125% of rated load. The hybrid thermal prediction results show good agreement with detailed ANSYS Mechanical simulations, with a deviation of approximately 3% in the linear-load case and 0.016% in the nonlinear-load case. The results show that harmonic loading significantly increases load-related losses and hot-spot temperature, while also revealing a non-uniform temperature distribution that enables hot-spot localization. The obtained spatial hot-spot information supports insulation loss-of-life assessment and provides practical guidance for design improvement, sensor placement, periodic inspection/testing, spare-part planning, and condition-based maintenance under harmonic operating conditions.
- 21 May 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (22)
Generalization bounds and sample complexity for remaining useful life prediction from complete degradation trajectories
Data-driven remaining useful life (RUL) prediction requires complete degradation trajectories for training, yet such run-to-failure data are scarce and expensive. Practitioners currently lack principled guidance on how many failure examples suffice for a given model and accuracy target. This paper develops a sample complexity framework for RUL prediction comprising seven main results organised around three themes. First, we establish fundamental learning rates: a distribution-free generalization bound shows that the uniform deviation of the mean squared error decreases as Ο ( Β 2 √ p / n ), where p is the model complexity and n the number of trajectories, and a minimax lower bound proves that the Θ( p / n ) rate is unimprovable. Second, we quantify how domain knowledge accelerates learning: incorporating degradation physics reduces data requirements by up to two orders of magnitude for deep networks, a Bernstein-type analysis achieves the minimax-optimal Ο ( p / n ) rate under high signal-to-noise conditions, and closed-form penalties reveal when an incorrectly assumed physics model hurts rather than helps. Third, we characterise the impact of data quality: fleet variability induces an irreducible bias--variance tradeoff, while right-censored observations suffer an efficiency loss that depends critically on the degradation class. Closed-form expressions are provided for exponential, power-law, and stretched-exponential degradation. Cross-domain validation against published turbofan, battery, and bearing benchmarks confirms the theoretical predictions within a factor of 2--3 on average. The results yield practical guidelines for planning data collection, selecting model complexity, and evaluating physics model assumptions in prognostics applications.
- 21 May 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (22)
Generalization bounds and sample complexity for remaining useful life prediction from complete degradation trajectories
Data-driven remaining useful life (RUL) prediction requires complete degradation trajectories for training, yet such run-to-failure data are scarce and expensive. Practitioners currently lack principled guidance on how many failure examples suffice for a given model and accuracy target. This paper develops a sample complexity framework for RUL prediction comprising seven main results organised around three themes. First, we establish fundamental learning rates: a distribution-free generalization bound shows that the uniform deviation of the mean squared error decreases as Ο ( Β 2 √ p / n ), where p is the model complexity and n the number of trajectories, and a minimax lower bound proves that the Θ( p / n ) rate is unimprovable. Second, we quantify how domain knowledge accelerates learning: incorporating degradation physics reduces data requirements by up to two orders of magnitude for deep networks, a Bernstein-type analysis achieves the minimax-optimal Ο ( p / n ) rate under high signal-to-noise conditions, and closed-form penalties reveal when an incorrectly assumed physics model hurts rather than helps. Third, we characterise the impact of data quality: fleet variability induces an irreducible bias--variance tradeoff, while right-censored observations suffer an efficiency loss that depends critically on the degradation class. Closed-form expressions are provided for exponential, power-law, and stretched-exponential degradation. Cross-domain validation against published turbofan, battery, and bearing benchmarks confirms the theoretical predictions within a factor of 2--3 on average. The results yield practical guidelines for planning data collection, selecting model complexity, and evaluating physics model assumptions in prognostics applications.
- Open Access
- 25 April 2026
- Published by Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne in Eksploatacja i Niezawodność – Maintenance and Reliability
Charging Phase Health Indicators for Battery State-of-Health Estimation: A Systematic Comparison of CC, CV, and Combined Approaches under Cross-Battery Validation
Accurate State-of-Health estimation is essential for safe battery operation and cost-effective maintenance. Although numerous health indicators have been derived from constant-current (CC) and constant-voltage (CV) charging phases, their effectiveness under realistic cross-battery validation remains insufficiently studied. This work addresses this gap through a systematic comparison of CC-only, CV-only, and combined indicator sets using rigorous Leave-One-Battery-Out (LOBO) validation on the NASA battery aging dataset. Four CV-phase indicators and CC phase duration are evaluated individually and in combination. Results show that the combined CC+CV approach achieves the best performance (R2 = 0.874), confirming that CC and CV phases capture complementary degradation information. Moreover, a 119% performance gap is observed between standard 5-fold cross-validation and LOBO validation, indicating that conventional evaluation overestimates practical accuracy. Based on these findings, practical guidelines are provided for indicator selection under data and computational constraints.
- 25 April 2026
- Published by Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne in Eksploatacja i Niezawodność – Maintenance and Reliability
Open AccessCharging Phase Health Indicators for Battery State-of-Health Estimation: A Systematic Comparison of CC, CV, and Combined Approaches under Cross-Battery Validation
Accurate State-of-Health estimation is essential for safe battery operation and cost-effective maintenance. Although numerous health indicators have been derived from constant-current (CC) and constant-voltage (CV) charging phases, their effectiveness under realistic cross-battery validation remains insufficiently studied. This work addresses this gap through a systematic comparison of CC-only, CV-only, and combined indicator sets using rigorous Leave-One-Battery-Out (LOBO) validation on the NASA battery aging dataset. Four CV-phase indicators and CC phase duration are evaluated individually and in combination. Results show that the combined CC+CV approach achieves the best performance (R2 = 0.874), confirming that CC and CV phases capture complementary degradation information. Moreover, a 119% performance gap is observed between standard 5-fold cross-validation and LOBO validation, indicating that conventional evaluation overestimates practical accuracy. Based on these findings, practical guidelines are provided for indicator selection under data and computational constraints.
- Open Access
- 22 April 2026
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 144, 58-78
Transformer fault diagnosis using an efficient simulation-driven variational quantum classifier with domain-aware feature encoding
- 22 April 2026
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 144, 58-78
Open AccessTransformer fault diagnosis using an efficient simulation-driven variational quantum classifier with domain-aware feature encoding
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Développement de stratégies de maintenance prévisionnelle de systèmes multi-composants avec structure complexe
Aujourd'hui, les systèmes industriels deviennent de plus en plus complexes. Cette complexité est due d’une part à la structure du système qui ne se résume pas à des structures classiques en fiabilité, d’autre part à la prise en compte de composants présentant des phénomènes de dégradation graduelle que des systèmes de monitoring permettent de surveiller. Ceci mène à l'objectif de cette thèse portant sur le développement des stratégies de maintenance prévisionnelle pour des systèmes multi-composants complexes. Les politiques envisagées proposent notamment des stratégies de regroupement de composants permettant de tirer des dépendances économiques identifiées. Des facteurs d'importance permettant de prendre en compte la structure du système et la dépendance économique sont développés et combinés avec les évaluations de fiabilité prévisionnelle des composants pour l’élaboration de règles de décision de regroupement. De plus, un couplage des règles de décision de maintenance et de gestion des stocks est également étudié. L’ensemble des études menées montrent l’intérêt de la prise en compte de la fiabilité prévisionnelle des composants, des dépendances économiques et de la structure complexe du système dans l'aide à la décision de maintenance et de gestion des stocks. L’avantage des stratégies développées est vérifié en les comparant à d’autres existantes dans la littérature
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Développement de stratégies de maintenance prévisionnelle de systèmes multi-composants avec structure complexe
Aujourd'hui, les systèmes industriels deviennent de plus en plus complexes. Cette complexité est due d’une part à la structure du système qui ne se résume pas à des structures classiques en fiabilité, d’autre part à la prise en compte de composants présentant des phénomènes de dégradation graduelle que des systèmes de monitoring permettent de surveiller. Ceci mène à l'objectif de cette thèse portant sur le développement des stratégies de maintenance prévisionnelle pour des systèmes multi-composants complexes. Les politiques envisagées proposent notamment des stratégies de regroupement de composants permettant de tirer des dépendances économiques identifiées. Des facteurs d'importance permettant de prendre en compte la structure du système et la dépendance économique sont développés et combinés avec les évaluations de fiabilité prévisionnelle des composants pour l’élaboration de règles de décision de regroupement. De plus, un couplage des règles de décision de maintenance et de gestion des stocks est également étudié. L’ensemble des études menées montrent l’intérêt de la prise en compte de la fiabilité prévisionnelle des composants, des dépendances économiques et de la structure complexe du système dans l'aide à la décision de maintenance et de gestion des stocks. L’avantage des stratégies développées est vérifié en les comparant à d’autres existantes dans la littérature
- Open Access
- 1 March 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 17 (1) , 476-486
A novel single-switch DC-DC converter using the coupled inductor with ultra-high voltage gain
This paper presents an extremely high step-up DC-DC converter using a quadratic topology and a coupled inductor (CI). The proposed converter (PC) utilizes a single switch, simplifying the control strategy and reducing switching losses. A passive clamp circuit recycles leakage energy, reducing voltage stress (VS) on the MOSFET and enabling the implementation of a low on-state resistance switch for higher efficiency. Additionally, the quadratic structure and passive clamp circuit contribute to higher voltage gain (VG) and better performance. The converter’s operating principles, steady-state analysis, and component selection criteria are discussed in detail. The influence of magnetizing inductance, duty cycle, and parasitic components on the VG is also investigated, along with the system’s dynamic response under input voltage and load variations to ensure stable operation. A comparative evaluation with existing converters highlights its advantages. The PC is verified through SIMPLIS simulations, where key performance metrics such as VG and switching stress are analyzed. Furthermore, a hardware prototype with a power rating of 300 W is built to confirm the theory and showcase the converter’s performance. Experimental results demonstrate high efficiency, stable operation, and substantial VG, validating the converter’s feasibility for renewable energy systems (RES).
- 1 March 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 17 (1) , 476-486
Open AccessA novel single-switch DC-DC converter using the coupled inductor with ultra-high voltage gain
This paper presents an extremely high step-up DC-DC converter using a quadratic topology and a coupled inductor (CI). The proposed converter (PC) utilizes a single switch, simplifying the control strategy and reducing switching losses. A passive clamp circuit recycles leakage energy, reducing voltage stress (VS) on the MOSFET and enabling the implementation of a low on-state resistance switch for higher efficiency. Additionally, the quadratic structure and passive clamp circuit contribute to higher voltage gain (VG) and better performance. The converter’s operating principles, steady-state analysis, and component selection criteria are discussed in detail. The influence of magnetizing inductance, duty cycle, and parasitic components on the VG is also investigated, along with the system’s dynamic response under input voltage and load variations to ensure stable operation. A comparative evaluation with existing converters highlights its advantages. The PC is verified through SIMPLIS simulations, where key performance metrics such as VG and switching stress are analyzed. Furthermore, a hardware prototype with a power rating of 300 W is built to confirm the theory and showcase the converter’s performance. Experimental results demonstrate high efficiency, stable operation, and substantial VG, validating the converter’s feasibility for renewable energy systems (RES).
- 3 November 2025
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 51 (8) , 10591-10615
A Hybrid Ensemble Approach for Dissolved Gas Analysis-Based Power Transformer Fault Diagnosis Using SMOTE and GBDT
- 3 November 2025
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 51 (8) , 10591-10615
A Hybrid Ensemble Approach for Dissolved Gas Analysis-Based Power Transformer Fault Diagnosis Using SMOTE and GBDT