JSJiapeng Shi

Jiapeng Shi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiapeng Shi has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Baozhong Mu

    MOE Key Laboratory of Advanced Micro-Structured Materials, School of Physics Science and Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China

    1 shared publication
  • Dong Yang

    National Key Laboratory of Plasma Physics, Laser Fusion Research Center, China Academy of Engineering Physics 1 , Mianyang 621900

    1 shared publication
  • Jianjun Dong

    Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang 621900, China

    1 shared publication
  • Jie Xu

    Key Laboratory of Advanced Micro-structured Materials, Ministry of Education, Tongji University 4 , Shanghai 200092

    1 shared publication
  • Kuan Ren

    National Key Laboratory of Plasma Physics, Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang 621900, China

    1 shared publication
  • Mingtao Li

    Key Laboratory of Advanced Micro-structured Materials, Ministry of Education, Tongji University 4 , Shanghai 200092

    1 shared publication

Latest Publications

  • Open Access

    Dual-Color and High-Energy X-Ray Kirkpatrick–Baez Microscope for Laser Plasma Research

    by Mingtao Li, Jiapeng Shi, Mingxun Wang, Jie Xu, Xin Wang, Baozhong Mu, Jianjun Dong, Kuan Ren, Wei Liu, Xing Zhang, et al.

    High-energy X-ray diagnostic systems are crucial for understanding hotspot high-density area asymmetry, fuel mixing, and other phenomena in inertial confinement fusion. To meet the demand for hotspot electron temperature measurements, we developed a high-energy dual-channel Kirkpatrick–Baez microscope. This microscope is characterized by a dual high-energy response and high spatial resolution, enabling the observation of fine structures in high-density regions of a hotspot. Spectral drift was effectively mitigated by optimizing the grazing incidence angle, and the spatial and spectral domains were coupled through experimental alignment. Herein, we describe the optical design of the proposed microscope. Furthermore, we performed simulations and backlight imaging to validate the performance of the proposed system. The results show that the spatial resolution was better than 3 μm in the center and better than 6.5 μm in a field of view of 300 μm. The spectral response efficiencies at 11.4 and 17.48 keV were 7.41 × 10−8 and 5.77 × 10−8 sr, which deviate from the theoretical values by 3.01% and 6.79%, respectively.