SJSandeep Kumar Jha

Sandeep Kumar Jha

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sandeep Kumar Jha has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Shweta Panwar

    Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi 110016, India

    2 shared publications
  • Akanksha Priya

    Department of Laboratory Medicine, All India Institute of Medical Sciences, New Delhi, 110029, India

    1 shared publication
  • Amit Kumar Singh

    Department of Biomedical Engineering, Vignan's Foundation for Science, Technology & Research, Vadlamudi, Guntur. Andhra Pradesh, India

    1 shared publication
  • D. Syed Kasim

    Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, 110016, India

    1 shared publication
  • Harpreet Singh

    Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, 110016, India

    1 shared publication
  • K. K. Deepak

    Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, 110016, India

    1 shared publication

Latest Publications

  • Open Access

    A multivariate biosensor for non-invasive glucose and urea monitoring via saliva

    by Amit Kumar Singh, Shweta Panwar, Sandeep Kumar Jha

    Non-communicable diseases such as diabetes and chronic kidney disease (CKD) are major global health concerns due to associated high morbidity rates. Conventional monitoring of these diseases typically involves invasive methods, which can be painful and inconvenient for patients. This study highlights the development of a non-invasive, handheld optical biosensor capable of multivariate analysis using saliva samples. The device used two distinct paper-fluidic strips designed with different enzyme–dye combinations to detect glucose and urea. The biosensor also used ambient temperature compensation to address the differential sensitivity of these sensors owing to variations caused by temperature-dependent enzyme kinetics, thereby enhancing the measurement accuracy. Biosensor characteristics with the glucose oxidase-based strip showed a sensitivity of 1.93 count per mg per dL, linearity range from 8 to 358 mg dL−1, limit of detection (LOD) of 8 mg dL−1, and response time of 7.35 s. The clinical validation shows good correlation between saliva glucose levels (SGLs) and blood glucose levels (BGLs). The urea biosensor strip shows a sensitivity of 1.51 count per mg per dL, LOD of 5 mg dL−1, linearity range from 5 to 90 mg dL−1, and response time of 3 s. The clinical validation for the CKD patient shows a significant correlation between blood urea levels and saliva urea levels. The results demonstrate that the device offers a rapid, reliable, and user-friendly alternative for point-of-care testing (POCT), potentially improving patient compliance and management of diabetes and CKD. Significance: The findings suggest that this technology could represent a significant advancement in non-invasive diagnostic tools and can be used as a POCT by chronic patients.


  • Open Access

    A non-invasive device for glucose monitoring through saliva – a paradigm shift in diabetes care

    by Shweta Panwar, D. Syed Kasim, Harpreet Singh, Akanksha Priya, K. K. Deepak, Shyam Prakash, Sandeep Kumar Jha

    A portable bienzymatic biosensor enables rapid, non-invasive quantification of salivary glucose through colorimetric detection and derivative analysis for point-of-care diagnostics.