Taneeta Mindy Ganguly
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Taneeta Mindy Ganguly has a total of 150 co-authors. Here are the top co-authors by number of shared publications:
- Brian Litt
Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia
3 shared publications - William K. S. Ojemann
University of Pennsylvania
3 shared publications - Cornelia Drees
Mayo Clinic Phoenix Arizona USA
2 shared publications Erin C. Conrad
Penn Neuroscience Center—Neurology Perelman Center for Advanced Medicine, University of Pennsylvania Philadelphia Pennsylvania USA
2 shared publications- Erin C. Conrad
Center for Neuroengineering and Therapeutics, University of Pennsylvania
2 shared publications - Haoer Shi
Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA 19104 USA
2 shared publications
Latest Publications
- Open Access
How much does the reduced electroencephalographic montage matter for seizure detection? A large‐cohort simulation study
Objective: Subscalp electroencephalographic ( EEG) systems with few channels have emerged as promising solutions for ultra‐long‐term seizure monitoring, but the impact of montage configuration on automated seizure detection is unclear. We compared automated detection performance between full‐scalp and simulated reduced montages approximating published subscalp devices, and assessed variation by epilepsy type, lateralization, and localization. Methods: We conducted a retrospective cross‐sectional study of consecutive epilepsy monitoring unit (EMU) admissions from January 2017 to December 2024 at the Hospital of the University of Pennsylvania. Admissions with at least one clinician‐annotated seizure and at least one interictal segment of ≥20 min from any seizure were included. We simulated reduced bipolar montages from standard 10–20 scalp EEG. Three validated detectors, a one‐class support vector machine (SVM), a convolutional neural network (SPaRCNet), and a long short‐term memory autoregressive model with neural dynamic divergence method (NDD), were applied to montages and evaluated using event‐level F1 scores. We additionally evaluated the contributions of patient, detector, and montage to performance variance and associations between performance and epilepsy characteristics using linear mixed‐effects models. Results: A total of 466 admissions from 436 patients (mean [SD] age = 39.0 [14.4] years; 54.4% female) met inclusion criteria, comprising 1683 seizures and 1527 interictal clips. SPaRCNet achieved the highest performance (mean [SD] F1 = .61 [.30]), followed by NDD (.56 [.28]) and SVM (.39 [.25]). Absolute decreases in F1 score with reduced montages were modest (≤.09). Patient admission accounted for the most of performance variance (29.2%), followed by detector (10.3%), whereas montage contributed minimally (.4%). Performance between full and reduced montages was correlated ( ρ = .29–.73). Significance: Automated seizure detection performance was primarily driven by patient and algorithm factors rather than montage. Findings support the feasibility of seizure monitoring with reduced montages approximating chronic subscalp device geometries, despite the need for improved detection algorithms, and suggest that EMU‐based full‐montage performance could help identify candidates for these devices.
Open AccessHow much does the reduced electroencephalographic montage matter for seizure detection? A large‐cohort simulation study
Objective: Subscalp electroencephalographic ( EEG) systems with few channels have emerged as promising solutions for ultra‐long‐term seizure monitoring, but the impact of montage configuration on automated seizure detection is unclear. We compared automated detection performance between full‐scalp and simulated reduced montages approximating published subscalp devices, and assessed variation by epilepsy type, lateralization, and localization. Methods: We conducted a retrospective cross‐sectional study of consecutive epilepsy monitoring unit (EMU) admissions from January 2017 to December 2024 at the Hospital of the University of Pennsylvania. Admissions with at least one clinician‐annotated seizure and at least one interictal segment of ≥20 min from any seizure were included. We simulated reduced bipolar montages from standard 10–20 scalp EEG. Three validated detectors, a one‐class support vector machine (SVM), a convolutional neural network (SPaRCNet), and a long short‐term memory autoregressive model with neural dynamic divergence method (NDD), were applied to montages and evaluated using event‐level F1 scores. We additionally evaluated the contributions of patient, detector, and montage to performance variance and associations between performance and epilepsy characteristics using linear mixed‐effects models. Results: A total of 466 admissions from 436 patients (mean [SD] age = 39.0 [14.4] years; 54.4% female) met inclusion criteria, comprising 1683 seizures and 1527 interictal clips. SPaRCNet achieved the highest performance (mean [SD] F1 = .61 [.30]), followed by NDD (.56 [.28]) and SVM (.39 [.25]). Absolute decreases in F1 score with reduced montages were modest (≤.09). Patient admission accounted for the most of performance variance (29.2%), followed by detector (10.3%), whereas montage contributed minimally (.4%). Performance between full and reduced montages was correlated ( ρ = .29–.73). Significance: Automated seizure detection performance was primarily driven by patient and algorithm factors rather than montage. Findings support the feasibility of seizure monitoring with reduced montages approximating chronic subscalp device geometries, despite the need for improved detection algorithms, and suggest that EMU‐based full‐montage performance could help identify candidates for these devices.
- Open Access
Responsive stimulation of the thalamus for idiopathic generalized epilepsy: Results of the randomized controlled NAUTILUS trial through 18 months
Objective: This study was undertaken to evaluate the safety and effectiveness of responsive thalamic stimulation as adjunctive therapy for drug‐resistant idiopathic generalized epilepsy (IGE) with generalized tonic–clonic seizures (GTCSs). Methods: NAUTILUS is a prospective, multicenter, single‐blind, randomized sham‐controlled pivotal trial. Patients were ≥12 years of age with drug‐resistant IGE and ≥2 GTCSs over a 3‐month baseline. Bilateral depth leads were targeted to the centromedian thalamus. One month later, patients were randomized to Active (responsive stimulation, n = 44) or Sham (no stimulation, n = 43). The effectiveness evaluation period (EEP) began 3 months postimplant through 1 year. After a second GTCS in the EEP, patients transitioned to open‐label active stimulation. The primary safety endpoint was the serious adverse device‐related event (SADE) rate at 84 days postimplant. The primary effectiveness endpoint was time‐to‐second‐GTCS during the EEP. Additional endpoints included median percent change in days with any generalized seizure, GTCS frequency, and responder rate (RR). Results: Eighty‐seven patients were implanted across 23 US centers. The SADE rate was significantly below the performance goal (6.9%, p < .0001), with no adverse effects on cognition, mood, or sleep. The prespecified primary effectiveness endpoint was not significant. However, a post hoc mixed‐effects model considering all EEP days demonstrated greater GTCS reduction in the originally randomized Active group (61%) compared to patients originally randomized to Sham (49%, p = .030). Eighteen‐month outcomes included 76.8% median GTCS reduction, 62.5% RR, 40% GTCS‐free at that timepoint, and 77.8% median reduction in days with any generalized seizure. More than 90% of patients and 86% of physicians reported improvement on Global Impression of Change scales. Significance: NAUTILUS is the first randomized controlled neuromodulation trial in IGE. Responsive thalamic stimulation provided a clinically meaningful and durable reduction in seizures with an acceptable safety profile, offering a much‐needed option for drug‐resistant IGE.
Open AccessResponsive stimulation of the thalamus for idiopathic generalized epilepsy: Results of the randomized controlled NAUTILUS trial through 18 months
Objective: This study was undertaken to evaluate the safety and effectiveness of responsive thalamic stimulation as adjunctive therapy for drug‐resistant idiopathic generalized epilepsy (IGE) with generalized tonic–clonic seizures (GTCSs). Methods: NAUTILUS is a prospective, multicenter, single‐blind, randomized sham‐controlled pivotal trial. Patients were ≥12 years of age with drug‐resistant IGE and ≥2 GTCSs over a 3‐month baseline. Bilateral depth leads were targeted to the centromedian thalamus. One month later, patients were randomized to Active (responsive stimulation, n = 44) or Sham (no stimulation, n = 43). The effectiveness evaluation period (EEP) began 3 months postimplant through 1 year. After a second GTCS in the EEP, patients transitioned to open‐label active stimulation. The primary safety endpoint was the serious adverse device‐related event (SADE) rate at 84 days postimplant. The primary effectiveness endpoint was time‐to‐second‐GTCS during the EEP. Additional endpoints included median percent change in days with any generalized seizure, GTCS frequency, and responder rate (RR). Results: Eighty‐seven patients were implanted across 23 US centers. The SADE rate was significantly below the performance goal (6.9%, p < .0001), with no adverse effects on cognition, mood, or sleep. The prespecified primary effectiveness endpoint was not significant. However, a post hoc mixed‐effects model considering all EEP days demonstrated greater GTCS reduction in the originally randomized Active group (61%) compared to patients originally randomized to Sham (49%, p = .030). Eighteen‐month outcomes included 76.8% median GTCS reduction, 62.5% RR, 40% GTCS‐free at that timepoint, and 77.8% median reduction in days with any generalized seizure. More than 90% of patients and 86% of physicians reported improvement on Global Impression of Change scales. Significance: NAUTILUS is the first randomized controlled neuromodulation trial in IGE. Responsive thalamic stimulation provided a clinically meaningful and durable reduction in seizures with an acceptable safety profile, offering a much‐needed option for drug‐resistant IGE.
- Open Access
Feasibility and signal quality of the Minder® implantable continuous EEG monitoring® system compared to 10–20 scalp electrodes over extended monitoring periods
Objective: To evaluate the signal quality of the Minder implantable continuous EEG monitoring (iCEM) system compared to traditional scalp EEG in the context of long‐term, continuous monitoring in individuals with epilepsy. Methods: Twenty‐six patients implanted with the Minder iCEM system (November 2019 to July 2023) underwent 7‐day video‐EEG co‐monitoring with full montage scalp EEG at 4 and 24 weeks post‐implantation. Co‐monitored EEG segments were rated for clarity on a 5‐point ordinal scale by blinded expert reviewers for ictal and interictal periods. Minder vs scalp ratings were compared using Wilcoxon signed‐rank test; 4‐ vs 24‐week comparisons used Wilcoxon rank‐sum test. Objective quantitative EEG analysis of the signal bandwidth was performed by application of spectral coherence analysis and Pearson's correlation coefficients. Results: No significant difference was found between interictal signal clarity reviewer ratings for Minder vs scalp EEG ( p = .97), and there was no statistically significant difference between the Minder signal clarity ratings at 4 vs 24 weeks ( p = .95). Pearson's correlation between Minder vs scalp EEG also indicated a high degree of similarity (median correlation = .69) and no statistically significant difference between correlations at 4 vs 24 weeks ( p = .99). All electrographic seizures identified on full 10–20 scalp EEG were also identified on Minder; however, the full 10–20 montage received statistically higher seizure clarity ratings than Minder ( p < .001). Significance: This study supports the feasibility of sub‐scalp EEG as a reliable long‐term monitoring tool. Interictal signal quality was statistically equivalent to limited‐montage scalp EEG, and all seizures identified on full 10–20 scalp EEG were also visualized on Minder. The full 10–20 montage did receive statistically higher seizure clarity ratings, reflecting its greater spatial resolution. The signal quality was stable through 24 weeks, demonstrating the fidelity of the device. These findings position the Minder system as a complement to full montage scalp EEG, particularly in ambulatory settings where continuous long‐term recording is required.
Open AccessFeasibility and signal quality of the Minder® implantable continuous EEG monitoring® system compared to 10–20 scalp electrodes over extended monitoring periods
Objective: To evaluate the signal quality of the Minder implantable continuous EEG monitoring (iCEM) system compared to traditional scalp EEG in the context of long‐term, continuous monitoring in individuals with epilepsy. Methods: Twenty‐six patients implanted with the Minder iCEM system (November 2019 to July 2023) underwent 7‐day video‐EEG co‐monitoring with full montage scalp EEG at 4 and 24 weeks post‐implantation. Co‐monitored EEG segments were rated for clarity on a 5‐point ordinal scale by blinded expert reviewers for ictal and interictal periods. Minder vs scalp ratings were compared using Wilcoxon signed‐rank test; 4‐ vs 24‐week comparisons used Wilcoxon rank‐sum test. Objective quantitative EEG analysis of the signal bandwidth was performed by application of spectral coherence analysis and Pearson's correlation coefficients. Results: No significant difference was found between interictal signal clarity reviewer ratings for Minder vs scalp EEG ( p = .97), and there was no statistically significant difference between the Minder signal clarity ratings at 4 vs 24 weeks ( p = .95). Pearson's correlation between Minder vs scalp EEG also indicated a high degree of similarity (median correlation = .69) and no statistically significant difference between correlations at 4 vs 24 weeks ( p = .99). All electrographic seizures identified on full 10–20 scalp EEG were also identified on Minder; however, the full 10–20 montage received statistically higher seizure clarity ratings than Minder ( p < .001). Significance: This study supports the feasibility of sub‐scalp EEG as a reliable long‐term monitoring tool. Interictal signal quality was statistically equivalent to limited‐montage scalp EEG, and all seizures identified on full 10–20 scalp EEG were also visualized on Minder. The full 10–20 montage did receive statistically higher seizure clarity ratings, reflecting its greater spatial resolution. The signal quality was stable through 24 weeks, demonstrating the fidelity of the device. These findings position the Minder system as a complement to full montage scalp EEG, particularly in ambulatory settings where continuous long‐term recording is required.
- Open Access
- 12 May 2026
- Published by Wolters Kluwer Health in Neurology
- Vol. 106 (9) , e214875
Postapproval Study for Brain-Responsive Neurostimulation for Drug-Resistant Focal Epilepsy
Background and ObjectivesNeuromodulation therapies are approved for the treatment of focal epilepsy based on data from randomized controlled trials (RCTs). After approval of a responsive direct bra...
- 12 May 2026
- Published by Wolters Kluwer Health in Neurology
- Vol. 106 (9) , e214875
Open AccessPostapproval Study for Brain-Responsive Neurostimulation for Drug-Resistant Focal Epilepsy
Background and ObjectivesNeuromodulation therapies are approved for the treatment of focal epilepsy based on data from randomized controlled trials (RCTs). After approval of a responsive direct bra...
- Open Access
How Much Does the Reduced EEG Montage Matter for Seizure Detection?: A Large-Cohort Simulation Study
Importance: Implantable sub-scalp EEG systems with a small number of channels have emerged as promising solutions for long-term seizure monitoring in patients with epilepsy. How seizure detection performance varies by montage configuration is unknown. Objective: To quantify how automated seizure detection performance differs between full and reduced montages, and how these differences vary by epilepsy characteristics. Design: Retrospective cross-sectional study. Setting: Single-center at the Hospital of the University of Pennsylvania Epilepsy Monitoring Unit (EMU). Participants: EEG data from 2281 consecutive EMU admissions between January 2017 and December 2024 were screened. Admissions with at least one annotated seizure and one interictal clip ≥20 minutes from any seizure were included. Exposure: Computational simulation of published sub-scalp device montages using standard 10-20 EEG channels. Main Outcomes and Measures: The primary outcome was event-based F1 scores evaluated for three published seizure detectors—a one-class support vector machine (SVM), a convolutional neural network (SPaRCNet), and a long short-term memory autoregressive model (NDD)—across montages. Results: A total of 466 admissions from 436 patients (mean [SD] age, 39.0 [14.4] years; 54.4% female) met inclusion criteria, comprising 1683 seizures and 1527 interictal clips. SPaRCNet achieved the highest performance (mean [SD] F1, 0.61 [0.30]), followed by NDD (0.56 [0.28]) and SVM (0.39 [0.25]). Performance decreased by at most 0.09 with reduced montages, depending on detectors. Patient factors accounted for the largest proportion of performance variance (29.2%), followed by detector choice (10.3%). Montage effects were minimal (0.4%), despite variation in optimal montage across detectors. Reduced-montage performance correlated moderately to highly with full-montage performance (ρ=0.29–0.73), suggesting full-montage performance could help identify patients suitable for sub-scalp devices. Missed seizures were associated with lower amplitude and bandpowers than detected seizures, though they remained distinguishable from interictal data. Conclusions and Relevance: Automated seizure detection achieved comparable accuracy, with only modest reductions, under simulated reduced montages. Performance differences were driven primarily by detector- and patient-level factors rather than montage. These findings support the feasibility of accurately detecting seizures with published sub-scalp devices and highlight the need for improved algorithms to optimize performance. Key Findings: Question: How do automated seizure detection algorithms perform with reduced-channel montages simulating published sub-scalp devices? Findings: In this retrospective cross-sectional study, seizure detection performance decreased only modestly on reduced montages relative to the full montage (absolute F1 change −0.09 to 0.014), whereas patient- and algorithm-level factors accounted for most of performance variance (29.2% and 10.3%, respectively). Algorithm performance on full montage recordings was moderately correlated with performance on reduced channel montages (ρ=0.29–0.73). Meaning: Reduced-montage sub-scalp devices are promising for ultra-long-term monitoring, but best performance requires selecting the right patients. Patient-specific seizure detectors will likely be required to optimize long-term performance.
Open AccessHow Much Does the Reduced EEG Montage Matter for Seizure Detection?: A Large-Cohort Simulation Study
Importance: Implantable sub-scalp EEG systems with a small number of channels have emerged as promising solutions for long-term seizure monitoring in patients with epilepsy. How seizure detection performance varies by montage configuration is unknown. Objective: To quantify how automated seizure detection performance differs between full and reduced montages, and how these differences vary by epilepsy characteristics. Design: Retrospective cross-sectional study. Setting: Single-center at the Hospital of the University of Pennsylvania Epilepsy Monitoring Unit (EMU). Participants: EEG data from 2281 consecutive EMU admissions between January 2017 and December 2024 were screened. Admissions with at least one annotated seizure and one interictal clip ≥20 minutes from any seizure were included. Exposure: Computational simulation of published sub-scalp device montages using standard 10-20 EEG channels. Main Outcomes and Measures: The primary outcome was event-based F1 scores evaluated for three published seizure detectors—a one-class support vector machine (SVM), a convolutional neural network (SPaRCNet), and a long short-term memory autoregressive model (NDD)—across montages. Results: A total of 466 admissions from 436 patients (mean [SD] age, 39.0 [14.4] years; 54.4% female) met inclusion criteria, comprising 1683 seizures and 1527 interictal clips. SPaRCNet achieved the highest performance (mean [SD] F1, 0.61 [0.30]), followed by NDD (0.56 [0.28]) and SVM (0.39 [0.25]). Performance decreased by at most 0.09 with reduced montages, depending on detectors. Patient factors accounted for the largest proportion of performance variance (29.2%), followed by detector choice (10.3%). Montage effects were minimal (0.4%), despite variation in optimal montage across detectors. Reduced-montage performance correlated moderately to highly with full-montage performance (ρ=0.29–0.73), suggesting full-montage performance could help identify patients suitable for sub-scalp devices. Missed seizures were associated with lower amplitude and bandpowers than detected seizures, though they remained distinguishable from interictal data. Conclusions and Relevance: Automated seizure detection achieved comparable accuracy, with only modest reductions, under simulated reduced montages. Performance differences were driven primarily by detector- and patient-level factors rather than montage. These findings support the feasibility of accurately detecting seizures with published sub-scalp devices and highlight the need for improved algorithms to optimize performance. Key Findings: Question: How do automated seizure detection algorithms perform with reduced-channel montages simulating published sub-scalp devices? Findings: In this retrospective cross-sectional study, seizure detection performance decreased only modestly on reduced montages relative to the full montage (absolute F1 change −0.09 to 0.014), whereas patient- and algorithm-level factors accounted for most of performance variance (29.2% and 10.3%, respectively). Algorithm performance on full montage recordings was moderately correlated with performance on reduced channel montages (ρ=0.29–0.73). Meaning: Reduced-montage sub-scalp devices are promising for ultra-long-term monitoring, but best performance requires selecting the right patients. Patient-specific seizure detectors will likely be required to optimize long-term performance.
- Open Access
- 4 April 2026
- Published by Elsevier in Epilepsy & Behavior
- Vol. 180, 111034
Disparities in epilepsy care: The role of provider decision-making
- 4 April 2026
- Published by Elsevier in Epilepsy & Behavior
- Vol. 180, 111034
Open AccessDisparities in epilepsy care: The role of provider decision-making
- Open Access
- 3 July 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (4) , 046003
Annotating neurophysiologic data at scale with optimized human input
Objective. Neuroscience experiments and devices are generating unprecedented volumes of data, but analyzing and validating them presents practical challenges, particularly in annotation. While expert annotation remains the gold standard, it is time consuming to obtain and often poorly reproducible. Although automated annotation approaches exist, they rely on labeled data first to train machine learning algorithms, which limits their scalability. A semi-automated annotation approach that integrates human expertise while optimizing efficiency at scale is critically needed. To address this, we present Annotation Co-pilot, a human-in-the-loop solution that leverages deep active learning (AL) and self-supervised learning (SSL) to improve intracranial EEG (iEEG) annotation, significantly reducing the amount of human annotations. Approach. We automatically annotated iEEG recordings from 28 humans and 4 dogs with epilepsy implanted with two neurodevices that telemetered data to the cloud for analysis. We processed 1500 h of unlabeled iEEG recordings to train a deep neural network using a SSL method Swapping Assignments between View to generate robust, dataset-specific feature embeddings for the purpose of seizure detection. AL was used to select only the most informative data epochs for expert review. We benchmarked this strategy against standard methods. Main result. Over 80 000 iEEG clips, totaling 1176 h of recordings were analyzed. The algorithm matched the best published seizure detectors on two datasets (NeuroVista and NeuroPace responsive neurostimulation) but required, on average, only 1/6 of the human annotations to achieve similar accuracy (area under the ROC curve of 0.9628 ± 0.015) and demonstrated better consistency than human annotators (Cohen’s Kappa of 0.95 ± 0.04). Significance. ‘Annotation Co-pilot’ demonstrated expert-level performance, robustness, and generalizability across two disparate iEEG datasets while reducing annotation time by an average of 83%. This method holds great promise for accelerating basic and translational research in electrophysiology, and potentially accelerating the pathway to clinical translation for AI-based algorithms and devices.
- 3 July 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (4) , 046003
Open AccessAnnotating neurophysiologic data at scale with optimized human input
Objective. Neuroscience experiments and devices are generating unprecedented volumes of data, but analyzing and validating them presents practical challenges, particularly in annotation. While expert annotation remains the gold standard, it is time consuming to obtain and often poorly reproducible. Although automated annotation approaches exist, they rely on labeled data first to train machine learning algorithms, which limits their scalability. A semi-automated annotation approach that integrates human expertise while optimizing efficiency at scale is critically needed. To address this, we present Annotation Co-pilot, a human-in-the-loop solution that leverages deep active learning (AL) and self-supervised learning (SSL) to improve intracranial EEG (iEEG) annotation, significantly reducing the amount of human annotations. Approach. We automatically annotated iEEG recordings from 28 humans and 4 dogs with epilepsy implanted with two neurodevices that telemetered data to the cloud for analysis. We processed 1500 h of unlabeled iEEG recordings to train a deep neural network using a SSL method Swapping Assignments between View to generate robust, dataset-specific feature embeddings for the purpose of seizure detection. AL was used to select only the most informative data epochs for expert review. We benchmarked this strategy against standard methods. Main result. Over 80 000 iEEG clips, totaling 1176 h of recordings were analyzed. The algorithm matched the best published seizure detectors on two datasets (NeuroVista and NeuroPace responsive neurostimulation) but required, on average, only 1/6 of the human annotations to achieve similar accuracy (area under the ROC curve of 0.9628 ± 0.015) and demonstrated better consistency than human annotators (Cohen’s Kappa of 0.95 ± 0.04). Significance. ‘Annotation Co-pilot’ demonstrated expert-level performance, robustness, and generalizability across two disparate iEEG datasets while reducing annotation time by an average of 83%. This method holds great promise for accelerating basic and translational research in electrophysiology, and potentially accelerating the pathway to clinical translation for AI-based algorithms and devices.