Sebastian Onder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sebastian Onder has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Simon Waid
Marietta Blau Institute for Particle Physics (MBI), Austrian Academy of Sciences, Dominikanerbastei 16, 1010 Vienna
10 shared publications - Thomas Bergauer
Institut für Hochenergiephysik
10 shared publications - Matthias Knopf
Institute of Atomic and Subatomic Physics, TU Wien, Stadionallee 2, 1020 Vienna, Austria
9 shared publications - Daniel Radmanovac
Marietta Blau Institute for Particle Physics (MBI), Austrian Academy of Sciences, Dominikanerbastei 16, 1010 Vienna
8 shared publications - Andreas Gsponer
Austrian Academy of Sciences (OeAW)
7 shared publications Jürgen Burin
Marietta Blau Institute for Particle Physics (former HEPHY), Nikolsdorfer Gasse 18, 1050 Vienna, Austria
6 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , C10008
Spectacular — a modular DAQ system for microdosimetry
Particle therapy using light ions like protons, helium-ions or carbon-ions enables precise tumor targeting with enhanced biological effectiveness while minimizing damage to healthy tissue. Successful treatment planning depends not only on the absorbed dose but also on quality of the radiation, as quantified by the linear energy transfer (LET). Microdosimetry provides a direct experimental determination of such quantities by measuring the energy deposited per incoming particle in micrometer-sized solid-state detectors representing the relevant biological scales. However, the small signal amplitudes and high particle rates in therapeutic ion beams (up to 10 10 s -1 ) challenge existing readout systems, which are not sufficiently optimized for reliable operation with respect to pileup and signal-to-noise ratio (SNR). To address this, a modular data acquisition (DAQ) system was developed to accelerate the design of custom readout electronics and sensor characterization in microdosimetry and related spectroscopic applications. Centered around a Xilinx Zynq system-on-chip, it combines real-time processing, high-bandwidth streaming, and high-resolution digitization (16 bit at 100 MSa s -1 ) to enable advanced digital signal processing. The platform integrates programmable power supplies, a bias-voltage filter, test-pulse generators, and flexible I/O. Detector and preamplifier front-ends are hosted on interchangeable daughter boards connected via a standardized interface, allowing different hardware configurations and readout algorithms to be evaluated on the same platform. The Spectacular DAQ system was successfully tested at the MedAustron ion therapy facility with custom charge-sensitive amplifiers and a diamond microdosimeter. First results demonstrate the feasibility and provide a proof-of-concept for potential future applications in clinical practice.
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , C10008
Open AccessSpectacular — a modular DAQ system for microdosimetry
Particle therapy using light ions like protons, helium-ions or carbon-ions enables precise tumor targeting with enhanced biological effectiveness while minimizing damage to healthy tissue. Successful treatment planning depends not only on the absorbed dose but also on quality of the radiation, as quantified by the linear energy transfer (LET). Microdosimetry provides a direct experimental determination of such quantities by measuring the energy deposited per incoming particle in micrometer-sized solid-state detectors representing the relevant biological scales. However, the small signal amplitudes and high particle rates in therapeutic ion beams (up to 10 10 s -1 ) challenge existing readout systems, which are not sufficiently optimized for reliable operation with respect to pileup and signal-to-noise ratio (SNR). To address this, a modular data acquisition (DAQ) system was developed to accelerate the design of custom readout electronics and sensor characterization in microdosimetry and related spectroscopic applications. Centered around a Xilinx Zynq system-on-chip, it combines real-time processing, high-bandwidth streaming, and high-resolution digitization (16 bit at 100 MSa s -1 ) to enable advanced digital signal processing. The platform integrates programmable power supplies, a bias-voltage filter, test-pulse generators, and flexible I/O. Detector and preamplifier front-ends are hosted on interchangeable daughter boards connected via a standardized interface, allowing different hardware configurations and readout algorithms to be evaluated on the same platform. The Spectacular DAQ system was successfully tested at the MedAustron ion therapy facility with custom charge-sensitive amplifiers and a diamond microdosimeter. First results demonstrate the feasibility and provide a proof-of-concept for potential future applications in clinical practice.
- Open Access
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10009
Measurements of the micro-spill structure of medical cyclotron and synchrotron beams and its impact on pulse pileup
Detector characterization and instrumentation testing are often performed at cyclotron and synchrotron facilities, many of which were originally developed for medical applications in cancer therapy. For particle physics experiments requiring a single-particle resolution, pileup can significantly degrade data quality, making precise knowledge of the beam time structure essential for selecting appropriate readout parameters. However, such information is often unavailable from the facilities and challenging to determine experimentally. Here, we report measurements of the spill time structure at two medical accelerator facilities using a silicon carbide (SiC) particle sensor coupled to a high-frequency readout system. Owing to its high carrier saturation velocity and the tolerance to large bias voltages, SiC is well suited for fast readout and measurements requiring precise timing. Using an analog readout circuit with 6 GHz bandwidth and custom SiC diodes, we characterize the micro-spill structure of both cyclotron and synchrotron beams on a sub-nanosecond timescale. The measured arrival-time distributions exhibit modulation with the accelerator RF frequencies, reflecting features of the extraction process. The resolved micro-spill structure enables quantitative estimation of pileup contributions and provides design constraints for future readout electronics. The presented results emphasize the importance of the characterization of the beam time-structure characterization for the development of precise readout systems.
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10009
Open AccessMeasurements of the micro-spill structure of medical cyclotron and synchrotron beams and its impact on pulse pileup
Detector characterization and instrumentation testing are often performed at cyclotron and synchrotron facilities, many of which were originally developed for medical applications in cancer therapy. For particle physics experiments requiring a single-particle resolution, pileup can significantly degrade data quality, making precise knowledge of the beam time structure essential for selecting appropriate readout parameters. However, such information is often unavailable from the facilities and challenging to determine experimentally. Here, we report measurements of the spill time structure at two medical accelerator facilities using a silicon carbide (SiC) particle sensor coupled to a high-frequency readout system. Owing to its high carrier saturation velocity and the tolerance to large bias voltages, SiC is well suited for fast readout and measurements requiring precise timing. Using an analog readout circuit with 6 GHz bandwidth and custom SiC diodes, we characterize the micro-spill structure of both cyclotron and synchrotron beams on a sub-nanosecond timescale. The measured arrival-time distributions exhibit modulation with the accelerator RF frequencies, reflecting features of the extraction process. The resolved micro-spill structure enables quantitative estimation of pileup contributions and provides design constraints for future readout electronics. The presented results emphasize the importance of the characterization of the beam time-structure characterization for the development of precise readout systems.
- 1 July 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (07) , C07020
A frontend ASIC for microdosimetry
Recent clinical evidence shows a correlation between LET and tumor control in carbon ion radiotherapy. This prompts the direct inclusion of LET into the treatment planning. Currently, LET is mainly extracted from simulations. Good clinical practice requires adopting measurement routines that correlate with LET, such as microdosimetry. In this work, we describe an ASIC for reading out microdosimeteric sensors. The ASIC is designed for input capacitances up to 3pF. It contains four readout channels, each with a different saturation charge ranging from 75fC to 3.2pC. In the 75fC range, at 1pF input capacitance and a shaping time of 1µs, the ASIC has an equivalent noise contribution (ENC) below 15e at ambient temperature. This low noise level is expected to enable new measurement possibilities, including the assessment of microdosimetric proton spectra in the low-LET region of the entrance channel, as well as studying the contribution of delta electrons.
- 1 July 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (07) , C07020
A frontend ASIC for microdosimetry
Recent clinical evidence shows a correlation between LET and tumor control in carbon ion radiotherapy. This prompts the direct inclusion of LET into the treatment planning. Currently, LET is mainly extracted from simulations. Good clinical practice requires adopting measurement routines that correlate with LET, such as microdosimetry. In this work, we describe an ASIC for reading out microdosimeteric sensors. The ASIC is designed for input capacitances up to 3pF. It contains four readout channels, each with a different saturation charge ranging from 75fC to 3.2pC. In the 75fC range, at 1pF input capacitance and a shaping time of 1µs, the ASIC has an equivalent noise contribution (ENC) below 15e at ambient temperature. This low noise level is expected to enable new measurement possibilities, including the assessment of microdosimetric proton spectra in the low-LET region of the entrance channel, as well as studying the contribution of delta electrons.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04076
512-channel SiC beam monitor electronics: single-particle up to clinical beam rates using commercial components
A 512-channel beam monitor was developed to measure beam parameters at particle rates from single particles up to clinical rates (several GHz). The system is designed for silicon carbide (SiC) strip sensors for increased radiation tolerance. The sensor readout uses four 128-channel analog charge-integrators with on-chip multiplexers, complemented by ADCs and a SoC module (FPGA + CPUs). Gigabit Ethernet, an SFP+ interface, and electrical and optical links enable communication with auxiliary systems. The system operates from a single power supply and was implemented on a 426×253 mm 2 , 12-layer PCB. All components, except for the sensors, are commercially available.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04076
512-channel SiC beam monitor electronics: single-particle up to clinical beam rates using commercial components
A 512-channel beam monitor was developed to measure beam parameters at particle rates from single particles up to clinical rates (several GHz). The system is designed for silicon carbide (SiC) strip sensors for increased radiation tolerance. The sensor readout uses four 128-channel analog charge-integrators with on-chip multiplexers, complemented by ADCs and a SoC module (FPGA + CPUs). Gigabit Ethernet, an SFP+ interface, and electrical and optical links enable communication with auxiliary systems. The system operates from a single power supply and was implemented on a 426×253 mm 2 , 12-layer PCB. All components, except for the sensors, are commercially available.
- Open Access
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01033
In-situ radiation damage study of silicon carbide detectors subjected to clinical proton beams
Silicon carbide (SiC) planar PiN diodes from two different manufacturers were irradiated with 252.7 MeV protons from a medical synchrotron. Over the course of two 8h irradiation shifts, the samples were exposed to increasing fluences ranging from 1.4 × 10 11 to 3.5 × 10 13 p + /cm 2 . Electrical characterizations, including IV and CV measurements, were performed both before and after irradiation using probe stations, and for selected samples even in-situ between fluence steps directly at the irradiation facility. The results show a gradual compensation of the effective epitaxial doping concentration with each incremental fluence step, observed as a reduction in capacitance before full depletion and confirmed by the extracted effective doping concentration. From these measurements, linear donor removal rates are determined for all sample groups, with values ranging from 4.2 cm -1 to 6.4 cm -1 . These findings provide a quantitative basis for understanding radiation-induced charge carrier removal in 4H-SiC devices and are relevant for predicting the performance and lifetime of future radiation-hard detector technologies, including 4H-SiC LGADs.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01033
Open AccessIn-situ radiation damage study of silicon carbide detectors subjected to clinical proton beams
Silicon carbide (SiC) planar PiN diodes from two different manufacturers were irradiated with 252.7 MeV protons from a medical synchrotron. Over the course of two 8h irradiation shifts, the samples were exposed to increasing fluences ranging from 1.4 × 10 11 to 3.5 × 10 13 p + /cm 2 . Electrical characterizations, including IV and CV measurements, were performed both before and after irradiation using probe stations, and for selected samples even in-situ between fluence steps directly at the irradiation facility. The results show a gradual compensation of the effective epitaxial doping concentration with each incremental fluence step, observed as a reduction in capacitance before full depletion and confirmed by the extracted effective doping concentration. From these measurements, linear donor removal rates are determined for all sample groups, with values ranging from 4.2 cm -1 to 6.4 cm -1 . These findings provide a quantitative basis for understanding radiation-induced charge carrier removal in 4H-SiC devices and are relevant for predicting the performance and lifetime of future radiation-hard detector technologies, including 4H-SiC LGADs.
- Open Access
Extraction of Electron and Hole Drift Velocities in Thin 4H-SiC PIN Detectors Using High-Frequency Readout Electronics
Silicon carbide (SiC) has been widely adopted in the semiconductor industry, particularly in power electronics, because of its high temperature stability, high breakdown field, and fast switching speeds. Its wide bandgap makes it an interesting candidate for radiation-hard particle detectors in high-energy physics and medical applications. Furthermore, the high electron and hole drift velocities in 4H-SiC enable devices suitable for ultra-fast particle detection and timing applications. However, currently, the front-end readout electronics used for 4H-SiC detectors constitute a bottleneck in investigations of the charge carrier drift. To address these limitations, a high-frequency readout board with an intrinsic bandwidth of 10 GHz was developed. With this readout, the transient current signals of a 4H-SiC diode with a diameter of 141 μm and a thickness of 50 μm upon UV laser, alpha particle, and high-energy proton beam excitation were recorded. In all three cases, the electron and hole drift can clearly be separated, which enables the extraction of the charge carrier drift velocities as a function of the electric field. These velocities, directly measured for the first time, provide a valuable comparison to Monte Carlo-simulated literature values and constitute an essential input for TCAD simulations. Finally, a complete simulation environment combining TCAD, the Allpix2 framework, and SPICE simulations is presented, which is in good agreement with the measured data.
Open AccessExtraction of Electron and Hole Drift Velocities in Thin 4H-SiC PIN Detectors Using High-Frequency Readout Electronics
Silicon carbide (SiC) has been widely adopted in the semiconductor industry, particularly in power electronics, because of its high temperature stability, high breakdown field, and fast switching speeds. Its wide bandgap makes it an interesting candidate for radiation-hard particle detectors in high-energy physics and medical applications. Furthermore, the high electron and hole drift velocities in 4H-SiC enable devices suitable for ultra-fast particle detection and timing applications. However, currently, the front-end readout electronics used for 4H-SiC detectors constitute a bottleneck in investigations of the charge carrier drift. To address these limitations, a high-frequency readout board with an intrinsic bandwidth of 10 GHz was developed. With this readout, the transient current signals of a 4H-SiC diode with a diameter of 141 μm and a thickness of 50 μm upon UV laser, alpha particle, and high-energy proton beam excitation were recorded. In all three cases, the electron and hole drift can clearly be separated, which enables the extraction of the charge carrier drift velocities as a function of the electric field. These velocities, directly measured for the first time, provide a valuable comparison to Monte Carlo-simulated literature values and constitute an essential input for TCAD simulations. Finally, a complete simulation environment combining TCAD, the Allpix2 framework, and SPICE simulations is presented, which is in good agreement with the measured data.
- Open Access
Design and simulation of a 4H-SiC low gain avalanche diode with trench-isolation
We present the design and simulation of a 30 $\mathrm{μm}$ thick 4H-SiC Low Gain Avalanche Diode (LGAD) optimized for high-voltage operation. A 2.4 $\mathrm{μm}$ thick epitaxially grown gain layer enables controlled internal amplification up to 1 kV reverse bias, while maintaining full depletion below 500 V. Electrical characteristics, including I-V, C-V, and gain behavior, were simulated in Synopsys Sentaurus Technology Computer-Aided Design (TCAD) using a quasi-1D geometry and verified across process-related variations in gain layer parameters. To ensure high-voltage stability and proper edge termination, a guard structure combining deep etched trenches and deep $p^+$ junction termination extension (JTE) implants was designed. TCAD simulations varying the guard structure dimensions yielded an optimized design with a breakdown voltage above 2.4 kV. A corresponding wafer run is currently processed at IMB-CNM, Barcelona.Open AccessDesign and simulation of a 4H-SiC low gain avalanche diode with trench-isolation
We present the design and simulation of a 30 $\mathrm{μm}$ thick 4H-SiC Low Gain Avalanche Diode (LGAD) optimized for high-voltage operation. A 2.4 $\mathrm{μm}$ thick epitaxially grown gain layer enables controlled internal amplification up to 1 kV reverse bias, while maintaining full depletion below 500 V. Electrical characteristics, including I-V, C-V, and gain behavior, were simulated in Synopsys Sentaurus Technology Computer-Aided Design (TCAD) using a quasi-1D geometry and verified across process-related variations in gain layer parameters. To ensure high-voltage stability and proper edge termination, a guard structure combining deep etched trenches and deep $p^+$ junction termination extension (JTE) implants was designed. TCAD simulations varying the guard structure dimensions yielded an optimized design with a breakdown voltage above 2.4 kV. A corresponding wafer run is currently processed at IMB-CNM, Barcelona. - Open Access
Extraction of Electron and Hole Drift Velocities in thin 4H-SiC PIN Detectors using High-Frequency Readout Electronics
Silicon carbide (SiC) has been widely adopted in the semiconductor industry, particularly in power electronics, because of its high temperature stability, high breakdown field, and fast switching speeds. Its wide band gap makes it an interesting candidate for radiation-hard particle detectors in high-energy physics and medical applications. Furthermore, the high electron and hole drift velocities in 4H-SiC enable devices suitable for ultra-fast particle detection and timing applications. However, currently, the front-end readout electronics used for 4H-SiC detectors constitute a bottleneck in investigations of the charge carrier drift. To address these limitations, a high-frequency readout board with an intrinsic bandwidth of 10 GHz was developed. With this readout, the transient current signals of a 4H-SiC diode with a diameter of 141 $\mathrm{μm}$ and a thickness of 50 $\mathrm{μm}$ upon UV-laser, alpha particle, and high-energy proton beam excitation were recorded. In all three cases, the electron and hole drift can clearly be separated, which enables the extraction of the charge carrier drift velocities as a function of the electric field. These velocities, for the first time directly measured, provide a valuable comparison to Monte-Carlo simulated literature values and constitute an essential input for TCAD simulations. Finally, a complete simulation environment combining TCAD, the Allpix$^2$ framework, and SPICE simulations is presented, in good agreement with the measured data.Open AccessExtraction of Electron and Hole Drift Velocities in thin 4H-SiC PIN Detectors using High-Frequency Readout Electronics
Silicon carbide (SiC) has been widely adopted in the semiconductor industry, particularly in power electronics, because of its high temperature stability, high breakdown field, and fast switching speeds. Its wide band gap makes it an interesting candidate for radiation-hard particle detectors in high-energy physics and medical applications. Furthermore, the high electron and hole drift velocities in 4H-SiC enable devices suitable for ultra-fast particle detection and timing applications. However, currently, the front-end readout electronics used for 4H-SiC detectors constitute a bottleneck in investigations of the charge carrier drift. To address these limitations, a high-frequency readout board with an intrinsic bandwidth of 10 GHz was developed. With this readout, the transient current signals of a 4H-SiC diode with a diameter of 141 $\mathrm{μm}$ and a thickness of 50 $\mathrm{μm}$ upon UV-laser, alpha particle, and high-energy proton beam excitation were recorded. In all three cases, the electron and hole drift can clearly be separated, which enables the extraction of the charge carrier drift velocities as a function of the electric field. These velocities, for the first time directly measured, provide a valuable comparison to Monte-Carlo simulated literature values and constitute an essential input for TCAD simulations. Finally, a complete simulation environment combining TCAD, the Allpix$^2$ framework, and SPICE simulations is presented, in good agreement with the measured data. - Open Access
- 13 September 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1082
Characterizing the delivered spill structure of medical proton and carbon-ion beams at MedAustron using a high frequency silicon carbide readout
- 13 September 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1082
Open AccessCharacterizing the delivered spill structure of medical proton and carbon-ion beams at MedAustron using a high frequency silicon carbide readout
- 2 September 2025
- Published by Elsevier in Microelectronic Engineering
- Vol. 301
Towards silicon carbide monolithic active pixel radiation sensors
- 2 September 2025
- Published by Elsevier in Microelectronic Engineering
- Vol. 301
Towards silicon carbide monolithic active pixel radiation sensors