Jonatan Šercl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jonatan Šercl has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Ondřej Vopička
Department of Physical Chemistry University of Chemistry and Technology Prague Czech Republic
4 shared publications - Jan Heyda
Department of Physical Chemistry University of Chemistry and Technology Prague Czechia
3 shared publications - Jongmin Lee
PSI Center for Neutron and Muon Sciences Paul Scherrer Institute Villigen PSI Switzerland
3 shared publications - Martin Melčák
Department of Physical Chemistry University of Chemistry and Technology Prague Czechia
3 shared publications - Pierre Boillat
Paul Scherrer Institute
3 shared publications - Pavel Trtik
Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, Villigen PSI, Switzerland
2 shared publications
Latest Publications
- Open Access
- 28 October 2026
- Published by Wiley in Advanced Physics Research
- Vol. 5 (11)
Fluids under High Pressure Insighted by Operando Neutron Imaging and Molecular Dynamics Simulations
Properties of fluids in fuel gas systems (high pressure) and catalytic reactors (high temperature and pressure) are essential for their modeling but scarcely available. Liquid toluene and methylcyclohexane have been operando observed upon pressurization with hydrogen, methane, or ethane using Neutron Imaging (NI). Studied systems mimic phase separation in fuel gases, for which interfacial tension, Henry's law volatility constant, apparent molar volume, diffusion coefficient of dissolved methane and ethane are experimentally provided, interfacial tension is measured for systems with hydrogen. This uniquely extensive basis of coupled experimental quantities has been compared with their Molecular Dynamics (MD) model predictions. Moreover, predictions of quantities inaccessible using NI, such as self‐diffusion coefficients, partial molar volumes, enthalpies and entropies of dissolution, or parameters of the Lennard‐Jones potential shed light on liquids exposed to fuel gases at high pressures. The MD model generally predicts system properties emerging from intermolecular interactions and can thus be used beyond the temperature and pressure limitations of the validation experiment. Following this concept, previously inaccessible diffusion coefficients in model bulk fluids mimicking the catalytic (de)hydrogenation of toluene are provided. This paves the way to detailed modeling of catalytic conversions in this Liquid Organic Hydrogen Carrier system.
- 28 October 2026
- Published by Wiley in Advanced Physics Research
- Vol. 5 (11)
Open AccessFluids under High Pressure Insighted by Operando Neutron Imaging and Molecular Dynamics Simulations
Properties of fluids in fuel gas systems (high pressure) and catalytic reactors (high temperature and pressure) are essential for their modeling but scarcely available. Liquid toluene and methylcyclohexane have been operando observed upon pressurization with hydrogen, methane, or ethane using Neutron Imaging (NI). Studied systems mimic phase separation in fuel gases, for which interfacial tension, Henry's law volatility constant, apparent molar volume, diffusion coefficient of dissolved methane and ethane are experimentally provided, interfacial tension is measured for systems with hydrogen. This uniquely extensive basis of coupled experimental quantities has been compared with their Molecular Dynamics (MD) model predictions. Moreover, predictions of quantities inaccessible using NI, such as self‐diffusion coefficients, partial molar volumes, enthalpies and entropies of dissolution, or parameters of the Lennard‐Jones potential shed light on liquids exposed to fuel gases at high pressures. The MD model generally predicts system properties emerging from intermolecular interactions and can thus be used beyond the temperature and pressure limitations of the validation experiment. Following this concept, previously inaccessible diffusion coefficients in model bulk fluids mimicking the catalytic (de)hydrogenation of toluene are provided. This paves the way to detailed modeling of catalytic conversions in this Liquid Organic Hydrogen Carrier system.
- Open Access
- 1 June 2026
- Published by Springer Nature
- p. 40-46
Shapes of Mobile Interfaces in Tubes Revealed by Neutron Imaging: Sensitivity Analysis for Three-Phase High-Pressure Systems from Methane, p-xylene, and Water
The determination of interfacial energy (hence interfacial tension) from the shapes of mobile interfaces in cylindrical tubes is a rather viable though seldom utilized method despite the relative ease of its implementation. In this work, neutron imaging is used to reveal the shapes of interfaces in the system of perdeuterated p -xylene ( p -C 8 D 10 ) layered over water (10.88 mol.% of H 2 O in D 2 O) and exposed to pressurized methane (CH 4 , from 1.0 to 101 bar) at 7.0 to 30.0 ℃ while enclosed in the titanium tubular cell. These non-tactile measurements are performed using relatively high spatial resolution (pixel size 20.3 μm). The sensitivity limits determining the uncertainty of thus derived interfacial tensions are analyzed. Interfacial tension for methane – p -xylene was determined at the experimental uncertainty of 2 mN⋅m −1 . Interfacial tension for p -xylene – water was estimated at the experimental uncertainty of 16 mN.m −1 . Water and p -xylene are severe formers of freeze-out from moist and/or hydrocarbons containing natural gas. We survey the conditions needed for the interfacial tension measurements of industrially very relevant systems with prospects of acceptable experimental uncertainties while utilizing the intrinsically straightforward and on the first principles based methodology.
- 1 June 2026
- Published by Springer Nature
- p. 40-46
Open AccessShapes of Mobile Interfaces in Tubes Revealed by Neutron Imaging: Sensitivity Analysis for Three-Phase High-Pressure Systems from Methane, p-xylene, and Water
The determination of interfacial energy (hence interfacial tension) from the shapes of mobile interfaces in cylindrical tubes is a rather viable though seldom utilized method despite the relative ease of its implementation. In this work, neutron imaging is used to reveal the shapes of interfaces in the system of perdeuterated p -xylene ( p -C 8 D 10 ) layered over water (10.88 mol.% of H 2 O in D 2 O) and exposed to pressurized methane (CH 4 , from 1.0 to 101 bar) at 7.0 to 30.0 ℃ while enclosed in the titanium tubular cell. These non-tactile measurements are performed using relatively high spatial resolution (pixel size 20.3 μm). The sensitivity limits determining the uncertainty of thus derived interfacial tensions are analyzed. Interfacial tension for methane – p -xylene was determined at the experimental uncertainty of 2 mN⋅m −1 . Interfacial tension for p -xylene – water was estimated at the experimental uncertainty of 16 mN.m −1 . Water and p -xylene are severe formers of freeze-out from moist and/or hydrocarbons containing natural gas. We survey the conditions needed for the interfacial tension measurements of industrially very relevant systems with prospects of acceptable experimental uncertainties while utilizing the intrinsically straightforward and on the first principles based methodology.
- Open Access
- 26 January 2026
- Published by Wiley in Advanced Materials Interfaces
- Vol. 13 (6)
Interfacial Behavior of Methane in Methane/ p ‐Xylene/Water Systems: First Principles Inspected Using Neutron Imaging and Molecular Dynamics Simulations
Pressurized gases adsorb on the gas‐liquid ( g ‐ l ) interfaces, thus reducing the interfacial tension (IFT). Gas‐saturated liquid–liquid ( l ‐ l ) emulsions occur in oil and gas wells, possible IFT changes due to saturation remain unclear. We study if the IFT reduction occurs for the model system of methane, p‐ xylene, and water. The neutron imaging (NI) observations of bulk ( g ‐ l ‐ l ) systems at 100 bar provide several quantities simultaneously from each experimental run, e.g., IFT for g ‐ l and methane diffusivity for the p‐ xylene rich phase, but does not sensitively provide IFT for the l ‐ l interface. The quantities derived for the p‐ xylene‐rich phase using NI allows us to calibrate molecular dynamics (MD) simulation, which is used for the predictions of IFT for l ‐ l , literature data for binary benzene/water ( l ‐ l ) system are used as the reference. Overall, no, or very minor effect (±1 mN m − 1 ) on IFT is robustly found up to methane saturation at 100 bar. Variation of partial charges on the p ‐xylene model from zero to quantum calculation‐based modulate the fine structure of p ‐xylene/water interface and has small, yet qualitative effect on IFT, resulting in a weak adsorption (−1 mN m −1 ), or weak depletion (+1 mN m −1 ) of methane from l‐l .
- 26 January 2026
- Published by Wiley in Advanced Materials Interfaces
- Vol. 13 (6)
Open AccessInterfacial Behavior of Methane in Methane/ p ‐Xylene/Water Systems: First Principles Inspected Using Neutron Imaging and Molecular Dynamics Simulations
Pressurized gases adsorb on the gas‐liquid ( g ‐ l ) interfaces, thus reducing the interfacial tension (IFT). Gas‐saturated liquid–liquid ( l ‐ l ) emulsions occur in oil and gas wells, possible IFT changes due to saturation remain unclear. We study if the IFT reduction occurs for the model system of methane, p‐ xylene, and water. The neutron imaging (NI) observations of bulk ( g ‐ l ‐ l ) systems at 100 bar provide several quantities simultaneously from each experimental run, e.g., IFT for g ‐ l and methane diffusivity for the p‐ xylene rich phase, but does not sensitively provide IFT for the l ‐ l interface. The quantities derived for the p‐ xylene‐rich phase using NI allows us to calibrate molecular dynamics (MD) simulation, which is used for the predictions of IFT for l ‐ l , literature data for binary benzene/water ( l ‐ l ) system are used as the reference. Overall, no, or very minor effect (±1 mN m − 1 ) on IFT is robustly found up to methane saturation at 100 bar. Variation of partial charges on the p ‐xylene model from zero to quantum calculation‐based modulate the fine structure of p ‐xylene/water interface and has small, yet qualitative effect on IFT, resulting in a weak adsorption (−1 mN m −1 ), or weak depletion (+1 mN m −1 ) of methane from l‐l .
- Open Access
- 7 January 2026
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 143 (12)
Membrane Polymers for the Pervaporative Separation of Polar Organics: Methanol and Acetonitrile
Methanol (MeOH) and acetonitrile (MeCN) are highly polar organic compounds occurring in HPLC waste eluates. Neither of them is evidently more hydrophilic, which renders their pervaporative separation unusual. To identify suitable membrane materials, the pervaporation of MeOH‐MeCN mixtures having composition near the azeotrope (68.3 mol % MeOH at 35.0°C) was studied. For this purpose, homogeneous membranes from well‐established polymers were investigated, namely cellulose triacetate (CTA), polysulfone (PSU), poly(1‐trimethylsilyl‐1‐propyne) (PTMSP), Matrimid (MIM), poly(dimethyl siloxane) rubber (PDMS), polylactic acid (PLA), and chloroprene rubber (CR). Materials with discernible MeCN selectivity, namely CR, MIM, and PDMS, were further examined at 35.0°C, 45.0°C, and 52.9°C with feeds of varying composition. Plasticization and swelling effects were analyzed using Broadband Dielectric Spectroscopy (BDS) and liquid sorption measurements. Permeability decreased with increasing content of the less sorbing MeOH (except for MIM); BDS measurements indicated plasticization by both components; MeCN sorbed more and appears more organophilic.
- 7 January 2026
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 143 (12)
Open AccessMembrane Polymers for the Pervaporative Separation of Polar Organics: Methanol and Acetonitrile
Methanol (MeOH) and acetonitrile (MeCN) are highly polar organic compounds occurring in HPLC waste eluates. Neither of them is evidently more hydrophilic, which renders their pervaporative separation unusual. To identify suitable membrane materials, the pervaporation of MeOH‐MeCN mixtures having composition near the azeotrope (68.3 mol % MeOH at 35.0°C) was studied. For this purpose, homogeneous membranes from well‐established polymers were investigated, namely cellulose triacetate (CTA), polysulfone (PSU), poly(1‐trimethylsilyl‐1‐propyne) (PTMSP), Matrimid (MIM), poly(dimethyl siloxane) rubber (PDMS), polylactic acid (PLA), and chloroprene rubber (CR). Materials with discernible MeCN selectivity, namely CR, MIM, and PDMS, were further examined at 35.0°C, 45.0°C, and 52.9°C with feeds of varying composition. Plasticization and swelling effects were analyzed using Broadband Dielectric Spectroscopy (BDS) and liquid sorption measurements. Permeability decreased with increasing content of the less sorbing MeOH (except for MIM); BDS measurements indicated plasticization by both components; MeCN sorbed more and appears more organophilic.
- 22 June 2025
- Published by Elsevier in Colloids and Surfaces A: Physicochemical and Engineering Aspects
- Vol. 725
Isomer-specific sorption of C8H10 aromatics in Matrimid®
- 22 June 2025
- Published by Elsevier in Colloids and Surfaces A: Physicochemical and Engineering Aspects
- Vol. 725
Isomer-specific sorption of C8H10 aromatics in Matrimid®