Masakazu Sugiyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Masakazu Sugiyama has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Behgol Bagheri
Research Center for Advanced Science and Technology (RCAST) The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8904, Japan
1 shared publication - Cai Liu
College of Integrated Circuits and Optoelectronic Chips, Shenzhen Technology University 3 , Shenzhen 518118
1 shared publication - Gaomin Li
College of Integrated Circuits and Optoelectronic Chips, Shenzhen Technology University, Shenzhen 518118, China
1 shared publication - Hassanet Sodabanlu
The University of Tokyo
1 shared publication - Hiromu Kumagai
Research Center for Advanced Science and Technology, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8904, Japan
1 shared publication - Michio Hashimoto
Research Center for Advanced Science and Technology (RCAST) The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8904, Japan
1 shared publication
Latest Publications
- Open Access
- 7 September 2025
- Published by MDPI AG in Inorganics
- Vol. 13 (9) , 302
Prototypes of Highly Effective Stress Balancing AlN Interlayers in MOVPE GaN-on-Si (111)
The GaN-on-Si virtual substrate is now an indispensable platform for the application of GaN in the fields of power devices, radio frequency, light-emitting devices, etc. Such applications are still in need of more effective stress balancing techniques to achieve higher quality and stress balance in GaN-on-Si at a lower thickness. In this study, three promising practical prototypes of highly effective stress-balancing structures are proposed to realize the concept of an ideal AlN interlayer (AlN-IL) featuring a completely relaxed lower AlN/GaN interface and a fully strained upper GaN/AlN interface. The first is a single-layer AlN interlayer grown via precursor pulsed-injection (PI-AlN-IL). The second combines a low-temperature AlN (LT-AlN) underlayer with a PI-AlN-IL. The third integrates LT-AlN with a high-temperature AlN cap. Compared with optimal conventional single-layer AlN interlayer references, all these designs more effectively induced compressive stress and strain in overlying GaN layers. This study opens new technical paths to balancing stress in GaN-on-Si systems at a reduced thickness more efficiently.
- 7 September 2025
- Published by MDPI AG in Inorganics
- Vol. 13 (9) , 302
Open AccessPrototypes of Highly Effective Stress Balancing AlN Interlayers in MOVPE GaN-on-Si (111)
The GaN-on-Si virtual substrate is now an indispensable platform for the application of GaN in the fields of power devices, radio frequency, light-emitting devices, etc. Such applications are still in need of more effective stress balancing techniques to achieve higher quality and stress balance in GaN-on-Si at a lower thickness. In this study, three promising practical prototypes of highly effective stress-balancing structures are proposed to realize the concept of an ideal AlN interlayer (AlN-IL) featuring a completely relaxed lower AlN/GaN interface and a fully strained upper GaN/AlN interface. The first is a single-layer AlN interlayer grown via precursor pulsed-injection (PI-AlN-IL). The second combines a low-temperature AlN (LT-AlN) underlayer with a PI-AlN-IL. The third integrates LT-AlN with a high-temperature AlN cap. Compared with optimal conventional single-layer AlN interlayer references, all these designs more effectively induced compressive stress and strain in overlying GaN layers. This study opens new technical paths to balancing stress in GaN-on-Si systems at a reduced thickness more efficiently.
- Open Access
Techno-Economic Assessment of Green Hydrogen Production in Australia Using Off-Grid Hybrid Resources of Solar and Wind
This study presents a techno-economic framework for assessing the potential of utilizing hybrid renewable energy sources (wind and solar) to produce green hydrogen, with a specific focus on Australia. The model’s objective is to equip decision-makers in the green hydrogen industry with a reliable methodology to assess the availability of renewable resources for cost-effective hydrogen production. To enhance the credibility of the analysis, the model integrates 10 min on-ground solar and wind data, uses a high-resolution power dispatch simulation, and considers electrolyzer operational thresholds. This study concentrates on five locations in Australia and employs high-frequency resource data to quantify wind and solar availability. A precise simulation of power dispatch for a large off-grid plant has been developed to analyze the PV/wind ratio, element capacities, and cost variables. The results indicate that the locations where wind turbines can produce cost-effective hydrogen are limited due to the high capital investment, which renders wind farms uneconomical for hydrogen production. Our findings show that only one location—Edithburgh, South Australia—under a 50% solar–50% wind scenario, achieves a hydrogen production cost of 10.3 ¢USD/Nm3, which is lower than the 100% solar scenario. In the other four locations, the 100% solar scenario proves to be the most cost-effective for green hydrogen production. This study suggests that precise and comprehensive resource assessment is crucial for developing hydrogen production plants that generate low-cost green hydrogen.
Open AccessTechno-Economic Assessment of Green Hydrogen Production in Australia Using Off-Grid Hybrid Resources of Solar and Wind
This study presents a techno-economic framework for assessing the potential of utilizing hybrid renewable energy sources (wind and solar) to produce green hydrogen, with a specific focus on Australia. The model’s objective is to equip decision-makers in the green hydrogen industry with a reliable methodology to assess the availability of renewable resources for cost-effective hydrogen production. To enhance the credibility of the analysis, the model integrates 10 min on-ground solar and wind data, uses a high-resolution power dispatch simulation, and considers electrolyzer operational thresholds. This study concentrates on five locations in Australia and employs high-frequency resource data to quantify wind and solar availability. A precise simulation of power dispatch for a large off-grid plant has been developed to analyze the PV/wind ratio, element capacities, and cost variables. The results indicate that the locations where wind turbines can produce cost-effective hydrogen are limited due to the high capital investment, which renders wind farms uneconomical for hydrogen production. Our findings show that only one location—Edithburgh, South Australia—under a 50% solar–50% wind scenario, achieves a hydrogen production cost of 10.3 ¢USD/Nm3, which is lower than the 100% solar scenario. In the other four locations, the 100% solar scenario proves to be the most cost-effective for green hydrogen production. This study suggests that precise and comprehensive resource assessment is crucial for developing hydrogen production plants that generate low-cost green hydrogen.