FSFelipe Kowaleski dos Santos

Felipe Kowaleski dos Santos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Felipe Kowaleski dos Santos has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Fixação combinada intramedular-externa com fios de Kirschner para fraturas das falanges: Descrição de técnica cirúrgica

    by Gabriel Ifran Alves, Antônio Lourenço Severo, Marcelo Barretos de Lemos, Osvandré Lech, Felipe Kowaleski, Ivânio Tagliari

    Resumo: A mobilização precoce é fundamental para a recuperação funcional após fraturas das falanges, mas muitos métodos de fixação ainda exigem imobilização prolongada, o que aumenta o risco de rigidez articular. Descrevemos uma técnica simples, segura e de baixo custo, que combina fios de Kirschner intramedulares e ligação externa, adaptada do método de Ulson, originalmente desenvolvido para fraturas do rádio distal. O procedimento consiste em redução fechada sob fluoroscopia, seguida da introdução de 2 fios intramedulares de 1,0 mm, cujas extremidades externas são dobradas e conectadas, e formam um quadro estável que permite mobilização imediata sem necessidade de imobilização. A técnica proporcionou fixação estável, consolidação óssea confiável e reabilitação precoce, com baixa taxa de complicações. Trata-se de uma opção prática e reprodutível, especialmente útil em contextos com recursos limitados.

  • Open Access

    Combined Intramedullary-External K-Wire Fixation for Phalangeal Fractures: Description of a Surgical Technique

    by Gabriel Ifran Alves, Antônio Lourenço Severo, Marcelo Barretos de Lemos, Osvandré Lech, Felipe Kowaleski, Ivânio Tagliari

    Although early mobilization is essential for functional recovery after phalangeal fractures, many fixation methods still require prolonged immobilization, increasing the risk of joint stiffness. We herein describe a simple, safe, and low-cost technique that combines intramedullary Kirschner wires (K-wires) with external connection, adapted from the Ulson method, which was originally developed for distal radius fractures. The procedure consists of closed reduction under fluoroscopy followed by the insertion of two 1.0-mm intramedullary wires. The external ends of these wires are bent and connected, forming a stable frame that enables immediate mobilization without the need for immobilization. The technique provided stable fixation, reliable bone healing, and early rehabilitation, with a low complication rate. It represents a practical and reproducible option, especially useful in resource-limited settings.

  • Open Access

    Analysis of Microbiological Findings on the Surface of External Fixator Pins Comparing Steel Pins with Hydroxyapatite-Coated Pins

    by Cristhopher Stoffel, Honório Octávio Cuadro Peixoto, Felipe Kowaleski dos Santos, Pedro Afonso Keller Licks, Fernando Baldy dos Reis, Mauro José Costa Salles

    To compare the microbial retrieval rates and the organism types on the surface of stainless-steel pins (SSPs) and hydroxyapatite-coated pins (HCPs) from external fixators (EFs).The present prospective, non-randomized, multicenter, comparative interventional cohort study occurred from April 2018 to October 2021. The sample consisted of 44 patients with EFs, including 33 with SSPs and 11 with HCPs. We collected two pins from each patient, the one with the best and the one with the worst clinical appearance according to the Maz-Oxford-Nuffield (MON) classification, in an aseptic manner, and sent them for microbiological analysis.The overall superficial infection (SI) rate was 52.3% (23 of 44 patients), affecting 45.5% (5 of 11) patients with HCPs and 54.5% (18 of 33) patients with SSPs (p = 0.732). Of the 88 pins, 43.2% (38 of 88 pins) yielded microbial identification, with 42 pathogens isolated. Staphylococcus aureus was the most frequent organism, accounting for 59.5% (25 of 42 pathogens) of the positive samples. In the best-looking pins, the microbial retrieval rate was significantly lower in HCPs than SSPs, with 18.2% (2 pathogens in 11 pins) and 45.5% (15 pathogens in 33 pins), respectively (p = 0.036). In the worst-looking pins, the microbial retrieval rate in HCPs and SSPs was 27.3% (3 pathogens in 11 pins) and 54.5% (18 pathogens in 33 pins), respectively (p = 0.036).Microbial retrieval rates were lower in HCPs than in SSPs. However, these differences did not impact clinical infection rates, which were similar in both groups.

  • Open Access

    Análise dos achados microbiológicos identificados na superfície dos pinos de fixadores externos comparando pinos de aço com pinos revestidos por hidroxiapatita

    by Cristhopher Stoffel, Honório Octávio Cuadro Peixoto, Felipe Kowaleski dos Santos, Pedro Afonso Keller Licks, Fernando Baldy dos Reis, Mauro José Costa Salles

    Resumo: Comparar as taxas de recuperação microbiana e os tipos de microrganismos identificados na superfície dos pinos de aço inoxidável (PAIs) e nos pinos revestidos com hidroxiapatita (PHAs) de fixadores externos (FEs).Este estudo de coorte prospectiva de intervenção, não randomizado, multicêntrico, comparative foi realizado entre abril de 2018 e outubro de 2021, com 44 pacientes tratados com FE, 33 dos quais receberam PAIs e 11 receberam PHAs. Foram coletados e enviados para análise microbiológica dois pinos de cada paciente, o de melhor e o de pior aspecto clínico conforme a classificação de Maz-Oxford-Nuffield (MON), de forma asséptica.A taxa de infecção (TI) superficial global foi de 52,3% (23 de 44 pacientes), sendo 45,5% (5 de 11 pacientes) entre pacientes que receberam PHAs e 54,5% (18 de 33 pacientes) entre pacientes que receberam PAIs, respectivamente (p = 0,732). Dos 88 pinos, 43,2% (38 de 88 pinos) apresentaram identificação microbiana, sendo isolados 42 patógenos no total. O Staphylococcus aureus foi o mais frequente, representando 59,5% (25 dos 42 patógenos). Nas amostras de “melhor aspecto,” a taxa de recuperação microbiana foi significativamente menor nos PHAs do que nos PAIs, 18,2% (2 patógenos em 11 pinos) e 45,5% (15 patógenos em 33 pinos), respectivamente (p = 0,036). Nas amostras de “pior aspecto,” a taxa de recuperação microbiana nos PHAs se nos PAIs foi 27,3% (3 patógenos em 11 pinos) e 54,5% (18 patógenos em 33 pinos), respectivamente (p = 0,036).As taxas de recuperação microbiana foram menores nos PHAs comparadas às dos PAIs. Entretanto, estas diferenças não impactaram nas taxas de infecção clínica, que foram semelhantes nos dois grupos.