Sumaiya Akhter Ria
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sumaiya Akhter Ria has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Jean-Paul Jay-Gerin
Department of Medical Imaging and Radiation Sciences, Faculty of Medicine and Health Sciences, Université de Sherbrooke, 3001, 12th Avenue Nord, Sherbrooke, QC J1H 5N4, Canada
2 shared publications - Jintana Meesungnoen
Department of Medical Imaging and Radiation Sciences, Faculty of Medicine and Health Sciences, Université de Sherbrooke, 3001, 12th Avenue Nord, Sherbrooke, QC J1H 5N4, Canada
2 shared publications
Latest Publications
- Open Access
- 27 August 2025
- Published by MDPI AG in Antioxidants
- Vol. 14 (9) , 1054
Molecular Hydrogen as an Antioxidant and Radioprotector: Mechanistic Insights from Monte Carlo Radiation-Chemical Simulations
(1) Background: Water, comprising about 70–80% of cellular mass, is the most abundant constituent of living cells. Upon exposure to ionizing radiation, water undergoes radiolysis, generating a variety of reactive species, including free radicals and molecular products. Among these, hydroxyl radicals (•OH) are particularly damaging due to their very high reactivity and their capacity to induce oxidative injury to vital biomolecules such as DNA, membrane lipids, and proteins. From a radiation-chemical perspective, this study investigates the selective scavenging ability of molecular hydrogen (H2) toward •OH radicals, with the aim of evaluating its potential as an antioxidant and radioprotective agent; (2) Methods: We employed our Monte Carlo track chemistry simulation code, IONLYS-IRT, to model the time-dependent yields of ROS in a neutral, aerated aqueous environment. The simulations included varying concentrations of dissolved H2 and, for comparison, cystamine—a well-known sulfur-containing radioprotector and antioxidant. Irradiation was simulated using 300 MeV protons, chosen to mimic the radiolytic effects of low linear energy transfer (LET) radiation, such as that of 60Co γ-rays or fast (>1 MeV) electrons; (3) Results: Our simulations quantitatively demonstrated that H2 selectively scavenges •OH radicals. Nevertheless, its scavenging efficiency was consistently lower than that of cystamine, which produced a faster and more pronounced suppression of •OH due to its higher reactivity and superior radical-quenching capacity; (4) Conclusions: Molecular hydrogen offers several unique advantages, including low toxicity, high diffusivity, selective scavenging of •OH radicals, and well-documented anti-inflammatory effects. Although it is less potent than cystamine in terms of radical-scavenging efficiency, its excellent safety profile and biological compatibility position H2 as a promising radioprotector and antioxidant for therapeutic applications targeting radiation-induced oxidative stress and inflammation.
- 27 August 2025
- Published by MDPI AG in Antioxidants
- Vol. 14 (9) , 1054
Open AccessMolecular Hydrogen as an Antioxidant and Radioprotector: Mechanistic Insights from Monte Carlo Radiation-Chemical Simulations
(1) Background: Water, comprising about 70–80% of cellular mass, is the most abundant constituent of living cells. Upon exposure to ionizing radiation, water undergoes radiolysis, generating a variety of reactive species, including free radicals and molecular products. Among these, hydroxyl radicals (•OH) are particularly damaging due to their very high reactivity and their capacity to induce oxidative injury to vital biomolecules such as DNA, membrane lipids, and proteins. From a radiation-chemical perspective, this study investigates the selective scavenging ability of molecular hydrogen (H2) toward •OH radicals, with the aim of evaluating its potential as an antioxidant and radioprotective agent; (2) Methods: We employed our Monte Carlo track chemistry simulation code, IONLYS-IRT, to model the time-dependent yields of ROS in a neutral, aerated aqueous environment. The simulations included varying concentrations of dissolved H2 and, for comparison, cystamine—a well-known sulfur-containing radioprotector and antioxidant. Irradiation was simulated using 300 MeV protons, chosen to mimic the radiolytic effects of low linear energy transfer (LET) radiation, such as that of 60Co γ-rays or fast (>1 MeV) electrons; (3) Results: Our simulations quantitatively demonstrated that H2 selectively scavenges •OH radicals. Nevertheless, its scavenging efficiency was consistently lower than that of cystamine, which produced a faster and more pronounced suppression of •OH due to its higher reactivity and superior radical-quenching capacity; (4) Conclusions: Molecular hydrogen offers several unique advantages, including low toxicity, high diffusivity, selective scavenging of •OH radicals, and well-documented anti-inflammatory effects. Although it is less potent than cystamine in terms of radical-scavenging efficiency, its excellent safety profile and biological compatibility position H2 as a promising radioprotector and antioxidant for therapeutic applications targeting radiation-induced oxidative stress and inflammation.
- Open Access
Modeling the Impact of Viscosity on Fricke Gel Dosimeter Radiolysis: A Radiation Chemical Simulation Approach
The Fricke gel dosimeter, a hydrogel-based chemical dosimeter containing dissolved ferrous sulfate, measures 3D radiation dose distributions by oxidizing Fe2+ to Fe3+ upon irradiation. This study investigates the variation in Fricke yield, G(Fe3+), from a radiation–chemical perspective in both standard and gel-like Fricke systems of varying viscosities, under low- and high-linear energy transfer (LET) conditions. We employed our Monte Carlo track chemistry code IONLYS-IRT, using protons of 300 MeV (LET~0.3 keV/µm) and 1 MeV (LET~25 keV/µm) as radiation sources. To assess the impact of viscosity on G(Fe3+), we systematically varied the diffusion coefficients of all radiolytic species in the Fricke gel, including Fe2+ and Fe3+ ions. Increasing gel viscosity reduces Fe3+ diffusion and stabilizes spatial dose distributions but also lowers G(Fe3+), compromising measurement accuracy and sensitivity—especially under high-LET irradiation. Our results show that an optimal Fricke gel dosimeter must balance these competing factors. Simulations with lower sulfuric acid concentrations (e.g., 0.05 M vs. 0.4 M) further revealed that G(Fe3+) values at ~100 s are nearly identical for both low- and high-LET conditions. This study underscores the utility of Monte Carlo simulations in modeling viscosity effects on Fricke gel radiolysis, guiding dosimeter optimization to maximize sensitivity and accuracy while preserving spatial dose distribution integrity.
Open AccessModeling the Impact of Viscosity on Fricke Gel Dosimeter Radiolysis: A Radiation Chemical Simulation Approach
The Fricke gel dosimeter, a hydrogel-based chemical dosimeter containing dissolved ferrous sulfate, measures 3D radiation dose distributions by oxidizing Fe2+ to Fe3+ upon irradiation. This study investigates the variation in Fricke yield, G(Fe3+), from a radiation–chemical perspective in both standard and gel-like Fricke systems of varying viscosities, under low- and high-linear energy transfer (LET) conditions. We employed our Monte Carlo track chemistry code IONLYS-IRT, using protons of 300 MeV (LET~0.3 keV/µm) and 1 MeV (LET~25 keV/µm) as radiation sources. To assess the impact of viscosity on G(Fe3+), we systematically varied the diffusion coefficients of all radiolytic species in the Fricke gel, including Fe2+ and Fe3+ ions. Increasing gel viscosity reduces Fe3+ diffusion and stabilizes spatial dose distributions but also lowers G(Fe3+), compromising measurement accuracy and sensitivity—especially under high-LET irradiation. Our results show that an optimal Fricke gel dosimeter must balance these competing factors. Simulations with lower sulfuric acid concentrations (e.g., 0.05 M vs. 0.4 M) further revealed that G(Fe3+) values at ~100 s are nearly identical for both low- and high-LET conditions. This study underscores the utility of Monte Carlo simulations in modeling viscosity effects on Fricke gel radiolysis, guiding dosimeter optimization to maximize sensitivity and accuracy while preserving spatial dose distribution integrity.