Jose Manuel Lorenzo Gallardo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jose Manuel Lorenzo Gallardo has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Beatriz Montalbán Pozas
RoboLab, Robotics, Artificial Vision & Building Laboratory, Department of Construction. Polytechnic School of Cáceres, University of Extremadura, 10003 Cáceres, Spain., Spain
3 shared publications - Marta Lucas Bonilla
RoboLab, Robotics, Artificial Vision & Building Laboratory, Department of Construction. Polytechnic School of Cáceres, University of Extremadura, 10003 Cáceres, Spain, Spain
3 shared publications - Cristina Nuevo-Gallardo
Escuela de Ingenierías Industriales, Universidad de Extremadura, 06006 Badajoz, Spain
2 shared publications - Inmaculada Bote Alonso1 shared publication
Latest Publications
- Open Access
- 11 January 2026
- Published by MDPI AG in Urban Science
- Vol. 10 (1) , 43
Urban Heat Islands: Their Influence on Building Heating and Cooling Energy Demand Throughout Local Climate Zones
The thermal influence of Urban Heat Islands (UHIs) is not limited to periods of high temperature but persists throughout the year. The present study utilizes hourly data collected over a period of one year from a network of hygrothermal monitoring stations with a high density, which were deployed across the city of Cáceres (Spain). The network was designed in accordance with the World Meteorological Organization’s guidelines for urban measurements (employing radiation footprints and surface roughness) and ensures representation of each Local Climate Zone (LCZ), characterized by those factors (such as building typology and density, urban fabric, vegetation, and anthropogenic activity, among others) that influence potential solar radiation absorption. The magnitude of the heat island effect in this city has been determined to be approximately 7 °C in summer and winter at the first hours of the morning. In order to assess the energy impact of UHIs, Cooling and Heating Degree Days (CDD and HDD) were calculated for both summer and winter periods across the different LCZs. Following the implementation of rigorous quality control procedures and the utilization of gap-filling techniques, the analysis yielded discrepancies in energy demand of up to 10% between LCZs within the city. The significance of incorporating UHIs into the design of building envelopes and climate control systems is underscored by these findings, with the potential to enhance both energy efficiency and occupant thermal comfort. This methodology is particularly relevant for extrapolation to larger and denser urban environments, where the intensification of UHI effects exerts a direct impact on energy consumption and costs. The following essay will provide a comprehensive overview of the relevant literature on the subject.
- 11 January 2026
- Published by MDPI AG in Urban Science
- Vol. 10 (1) , 43
Open AccessUrban Heat Islands: Their Influence on Building Heating and Cooling Energy Demand Throughout Local Climate Zones
The thermal influence of Urban Heat Islands (UHIs) is not limited to periods of high temperature but persists throughout the year. The present study utilizes hourly data collected over a period of one year from a network of hygrothermal monitoring stations with a high density, which were deployed across the city of Cáceres (Spain). The network was designed in accordance with the World Meteorological Organization’s guidelines for urban measurements (employing radiation footprints and surface roughness) and ensures representation of each Local Climate Zone (LCZ), characterized by those factors (such as building typology and density, urban fabric, vegetation, and anthropogenic activity, among others) that influence potential solar radiation absorption. The magnitude of the heat island effect in this city has been determined to be approximately 7 °C in summer and winter at the first hours of the morning. In order to assess the energy impact of UHIs, Cooling and Heating Degree Days (CDD and HDD) were calculated for both summer and winter periods across the different LCZs. Following the implementation of rigorous quality control procedures and the utilization of gap-filling techniques, the analysis yielded discrepancies in energy demand of up to 10% between LCZs within the city. The significance of incorporating UHIs into the design of building envelopes and climate control systems is underscored by these findings, with the potential to enhance both energy efficiency and occupant thermal comfort. This methodology is particularly relevant for extrapolation to larger and denser urban environments, where the intensification of UHI effects exerts a direct impact on energy consumption and costs. The following essay will provide a comprehensive overview of the relevant literature on the subject.
- Open Access
- 2 December 2025
- Published by MDPI AG in Preprints.org
Urban Heat Islands: Their Influence on Building Heating and Cooling Energy Demand Throughout Local Climate Zones
The thermal influence of Urban Heat Islands (UHIs) is not limited to periods of high temperature but persists throughout the year. The present study utilises hourly data collected over a period of one year from a network of hygrothermal monitoring stations with a high density, which were deployed across the city of Cáceres (Spain). The network was designed in accordance with the World Meteorological Organization's guidelines for urban measurements (employing radiation footprints and surface roughness) and ensures representation of each Local Climate Zone (LCZ), characterised by those factors (such as building typology and density, urban fabric, vegetation, and anthropogenic activity, among others) that influence potential solar radiation absorption. The magnitude of the heat island effect in this city has been determined to be approximately 7 °C in summer and winter at the first hours of the morning. In order to assess the energy impact of UHIs, Cooling and Heating Degree Days (CDD & HDD) were calculated for both summer and winter periods across the different LCZs. Following the implementation of rigorous quality control procedures and the utilisation of gap-filling techniques, the analysis yielded discrepancies in energy demand of up to 10% between LCZs within the city. The significance of incorporating UHIs into the design of building envelopes and climate control systems is underscored by these findings, with the potential to enhance both energy efficiency and occupant thermal comfort. This meth-odology is particularly relevant for extrapolation to larger and denser urban environments, where the intensification of UHI effects exerts a direct impact on energy consumption and costs. The following essay will provide a comprehensive overview of the relevant literature on the subject.
- 2 December 2025
- Published by MDPI AG in Preprints.org
Open AccessUrban Heat Islands: Their Influence on Building Heating and Cooling Energy Demand Throughout Local Climate Zones
The thermal influence of Urban Heat Islands (UHIs) is not limited to periods of high temperature but persists throughout the year. The present study utilises hourly data collected over a period of one year from a network of hygrothermal monitoring stations with a high density, which were deployed across the city of Cáceres (Spain). The network was designed in accordance with the World Meteorological Organization's guidelines for urban measurements (employing radiation footprints and surface roughness) and ensures representation of each Local Climate Zone (LCZ), characterised by those factors (such as building typology and density, urban fabric, vegetation, and anthropogenic activity, among others) that influence potential solar radiation absorption. The magnitude of the heat island effect in this city has been determined to be approximately 7 °C in summer and winter at the first hours of the morning. In order to assess the energy impact of UHIs, Cooling and Heating Degree Days (CDD & HDD) were calculated for both summer and winter periods across the different LCZs. Following the implementation of rigorous quality control procedures and the utilisation of gap-filling techniques, the analysis yielded discrepancies in energy demand of up to 10% between LCZs within the city. The significance of incorporating UHIs into the design of building envelopes and climate control systems is underscored by these findings, with the potential to enhance both energy efficiency and occupant thermal comfort. This meth-odology is particularly relevant for extrapolation to larger and denser urban environments, where the intensification of UHI effects exerts a direct impact on energy consumption and costs. The following essay will provide a comprehensive overview of the relevant literature on the subject.
- Open Access
- 1 January 2025
- Published by Wiley in Indoor Air
- Vol. 2025 (1)
Understanding the Impact of Thermal Performance on Thermal Comfort in Dwellings: A Large‐Sample Study With a Homogeneous User Profile
Initiatives abound for improving energy efficiency in existing dwellings stock, yet the impact in their indoor thermal comfort conditions, postretrofit performance, and comfort levels are insufficiently explored. Studies that evaluate this parameter, enabling the validation or adjustment of current policies of retrofit actions, would be essential. Thus, this paper details the thermal monitoring and behaviour of a sample of 92 dwellings with a homogeneous user profile, with the aim of identifying thermal and comfort patterns. For this purpose, continuous long‐term monitoring is proposed for the comparative analysis of time series data for different climatic periods, instead of complex and individual data collection in situ. In order to correlate the envelope’s thermal behaviour, buildings are characterised in terms of building typology and construction period, after which occupant behaviours are examined via questionnaires on self‐reported thermal sensations and adaptive actions. Key results point to a lack of relationship between the building typology and construction period and thermal performance, even after the implementation of energy efficiency improvement measures. Additionally, thermal comfort was found to be intermittent, albeit more present in winter than summer, with a marked heterogeneity when it comes to individual habits. These facts indicate that it is necessary to include additional thermal performance driving factors for determining practical comfort implications and characterising its correlation with energy efficiency.
- 1 January 2025
- Published by Wiley in Indoor Air
- Vol. 2025 (1)
Open AccessUnderstanding the Impact of Thermal Performance on Thermal Comfort in Dwellings: A Large‐Sample Study With a Homogeneous User Profile
Initiatives abound for improving energy efficiency in existing dwellings stock, yet the impact in their indoor thermal comfort conditions, postretrofit performance, and comfort levels are insufficiently explored. Studies that evaluate this parameter, enabling the validation or adjustment of current policies of retrofit actions, would be essential. Thus, this paper details the thermal monitoring and behaviour of a sample of 92 dwellings with a homogeneous user profile, with the aim of identifying thermal and comfort patterns. For this purpose, continuous long‐term monitoring is proposed for the comparative analysis of time series data for different climatic periods, instead of complex and individual data collection in situ. In order to correlate the envelope’s thermal behaviour, buildings are characterised in terms of building typology and construction period, after which occupant behaviours are examined via questionnaires on self‐reported thermal sensations and adaptive actions. Key results point to a lack of relationship between the building typology and construction period and thermal performance, even after the implementation of energy efficiency improvement measures. Additionally, thermal comfort was found to be intermittent, albeit more present in winter than summer, with a marked heterogeneity when it comes to individual habits. These facts indicate that it is necessary to include additional thermal performance driving factors for determining practical comfort implications and characterising its correlation with energy efficiency.