LLLuigigiuseppe Lamattina

Luigigiuseppe Lamattina

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luigigiuseppe Lamattina has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Distal Interlocking Long Stem in Revision Hip Arthroplasty: A Narrative Review

    by Lorenzo Milani, Giulio Pieratelli, Cesare Donadono, Luigi Giuseppe Lamattina, Alex Pizzo, Domenico Tigani

    Background/Objectives: Long interlocking cementless stems have proven useful in revision total hip arthroplasty since their introduction in the late 1980s. Their ability to provide firm fixation has been confirmed by biomechanical tests and clinical observations. The cumulative survival of older, non-coated straight stems has not always been satisfactory, especially in younger patients, and a high number of screw and implant failures has also been reported. This narrative review provides a comprehensive overview of interlocking stems in complex revision procedures, focusing on timing of weight bearing, clinical outcomes, and complications. Methods: PubMed, Google Scholar, and the Cochrane Library were searched using database-specific Boolean search strategies combining terms related to distal locking femoral stems and revision hip arthroplasty. Studies reporting outcomes of cementless distally locked stems in revision total hip arthroplasty were selected according to predefined inclusion and exclusion criteria. The reference lists of the selected articles were additionally screened to identify relevant studies not retrieved by the electronic searches. Results: Thirty-one studies were included in the review. Considerable heterogeneity was observed in study design, sample size, follow-up duration, implant characteristics, and outcome reporting. Distal interlocking stems generally provided satisfactory implant survival and stable fixation, with early or immediate weight bearing permitted in several reported series. Mechanical complications involving the stem and distal locking screws were reported predominantly with earlier implant designs, particularly straight, thin, uncoated stems. More recent curved and hydroxyapatite-coated designs showed favourable mid- and long-term outcomes. Aseptic loosening, infection, dislocation, and mechanical failures were variably reported across the included studies. Because of heterogeneity in follow-up periods, denominators, and completeness of complication reporting, pooled complication rates were not calculated. Conclusions: Satisfactory survival rates were observed, with an acceptable complication rate. Implant mechanical failure, excluding stems that were eventually withdrawn from the market, remains a marginal event that has been largely overcome by curved and coated stems. Therefore, the available literature suggests favorable mid- and long-term outcomes when interlocking stems are used for complex femoral revision procedures or periprosthetic fractures with isthmus deficiency.

  • Open Access

    Novel Clinical Applications of 3D-Printed Highly Porous Titanium for Off-the-Shelf Cementless Joint Replacement Prostheses

    by Domenico Tigani, Luigigiuseppe Lamattina, Nicole Puteo, Cesare Donadono, Lorenzo Banci, Marta Colombo, Alex Pizzo, Andrea Assenza

    In total joint replacement, early aseptic loosening of implants caused by inadequate initial fixation and late aseptic loosening due to stress shielding-related periprosthetic bone remodeling are the main causes of failure. Over the last two decades, additive manufacturing has been revolutionizing the design of cementless orthopaedic implants by enabling biomimetic, highly porous titanium structures that enhance bone ingrowth and osseointegration while reducing stress shielding. The synergy between optimized selective laser-melted highly porous titanium bearing components, ceramic-coated titanium articular surfaces, and vitamin E-stabilized polyethylene liners delivers several benefits essential for implant longevity: reliable initial fixation, improved biological fixation, reduced bone resorption caused by stress shielding, and lower osteolytic reactivity. These benefits have encouraged the synergetic use of these technologies in joint replacement in novel clinical applications. In recent years, novel off-the-shelf, 3D-printed, highly porous titanium implants have been introduced into hip and knee arthroplasty. These newly introduced implants appear to offer an innovative and promising solution, and are particularly indicated for young active patients, elderly patients with osteoporotic bones, and in complex cases. Future clinical research should confirm these novel implants’ superior results in comparison to the current state of the art in cementless joint replacement. The possibility of extending these technologies in the future to other clinical applications such as partial knee prosthesis is discussed.


  • Open Access

    Management of Acetabular Fractures with Total Hip Replacement: A Narrative Literature Review

    by Domenico Tigani, Luigigiuseppe Lamattina, Andrea Assenza, Giuseppe Melucci, Alex Pizzo, Cesare Donadono

    Open reduction and internal fixation (ORIF) is widely regarded as the primary treatment for acetabular fractures, but limitations arise in complex cases, leading to non-anatomical reductions and increased risk of post-traumatic osteoarthritis. Given the high incidence of secondary arthritis (12–57%) following ORIF, total hip arthroplasty (THA) is often necessitated, particularly in scenarios unsuitable for ORIF, such as extensive comminution or combined femoral head and neck fractures. The surgical landscape has shifted from a traditional “fix or replace” to a more integrated “fix and replace” approach, especially beneficial in managing elderly patients with osteoporotic bones. THA is applied across various timelines, including acute (0–3 weeks), delayed (3 weeks to 3 months), and late (beyond 3 months), each presenting distinct challenges and requiring specific strategies to optimize outcomes. The importance of precise bone defect classifications and the role of dual mobility cups in reducing dislocation risks are highlighted, alongside the use of modern surgical and fixation techniques to improve stability and patient outcomes. Enhanced recovery protocols and meticulous postoperative management are critical to addressing complications, such as infections and hardware interference, tailoring treatment approaches to each patient’s needs, and advancing care for complex acetabular fractures.