Peihuan Ye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peihuan Ye has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Chang Li
China Construction Eighth Engineering Division Co., Ltd., Shanghai 200112, China
1 shared publication - Minglei Ma
China Construction Eighth Engineering Division Co., Ltd., Shanghai 200112, China
1 shared publication - Mohd Nizam Shakimon
Faculty of Engineering, Science & Technology, Kuala Lumpur University of Science and Technology, Selangor, Malaysia
1 shared publication - Shiqian Zhang
China Construction Eighth Engineering Division Co., Ltd., Shanghai 200112, China
1 shared publication - Yuliang Chen
School of Civil Engineering and Architecture, Guangxi University of Science and Technology, Liuzhou 545006, China
1 shared publication - Yuliu Wei
Faculty of Engineering, Science & Technology, Kuala Lumpur University of Science and Technology, Kajang 43000, Malaysia
1 shared publication
Latest Publications
- Open Access
Fiber-Reinforced Coral Aggregate Concrete: A Review of Mechanical, Dynamic, and Durability Properties
Coral aggregate concrete (CAC) is a promising sustainable material for construction on remote islands, but it is often limited by relatively low strength and durability. Fiber reinforcement has therefore been introduced as an effective modification strategy. This review focuses on fiber-reinforced coral aggregate concrete (FRCAC), highlighting the roles of different synthetic and natural fibers in improving its performance. Firstly, the characteristics of coral aggregates and the effects of seawater mixing are summarized. Then, the influence of fiber incorporation on the mechanical behavior of CAC under static loading, including compressive, tensile, and flexural responses, is reviewed. In addition, the performance of FRCAC under dynamic and complex loading conditions, such as impact, cyclic, and triaxial loading, is discussed. Overall, fiber reinforcement significantly enhances the tensile strength, ductility, and energy dissipation capacity of CAC, particularly at high strain rates. The maximum reported improvements in splitting tensile strength and flexural strength can reach up to approximately 58% and 68%, respectively, depending on fiber type and dosage. However, the enhancements in compressive strength and elastic modulus are generally limited, with maximum reported increases of about 23% and 7%, respectively. Under multiaxial stress states, fibers mainly contribute to crack control and damage mitigation rather than substantial strength enhancement. Durability and environmental aspects are also addressed. Fiber addition may reduce chloride ingress in CAC, although long-term durability data remain limited. The use of coral aggregate must be balanced with the need to protect coral reefs. Finally, key knowledge gaps and future research directions are identified to support the sustainable application of FRCAC in marine infrastructure.
Open AccessFiber-Reinforced Coral Aggregate Concrete: A Review of Mechanical, Dynamic, and Durability Properties
Coral aggregate concrete (CAC) is a promising sustainable material for construction on remote islands, but it is often limited by relatively low strength and durability. Fiber reinforcement has therefore been introduced as an effective modification strategy. This review focuses on fiber-reinforced coral aggregate concrete (FRCAC), highlighting the roles of different synthetic and natural fibers in improving its performance. Firstly, the characteristics of coral aggregates and the effects of seawater mixing are summarized. Then, the influence of fiber incorporation on the mechanical behavior of CAC under static loading, including compressive, tensile, and flexural responses, is reviewed. In addition, the performance of FRCAC under dynamic and complex loading conditions, such as impact, cyclic, and triaxial loading, is discussed. Overall, fiber reinforcement significantly enhances the tensile strength, ductility, and energy dissipation capacity of CAC, particularly at high strain rates. The maximum reported improvements in splitting tensile strength and flexural strength can reach up to approximately 58% and 68%, respectively, depending on fiber type and dosage. However, the enhancements in compressive strength and elastic modulus are generally limited, with maximum reported increases of about 23% and 7%, respectively. Under multiaxial stress states, fibers mainly contribute to crack control and damage mitigation rather than substantial strength enhancement. Durability and environmental aspects are also addressed. Fiber addition may reduce chloride ingress in CAC, although long-term durability data remain limited. The use of coral aggregate must be balanced with the need to protect coral reefs. Finally, key knowledge gaps and future research directions are identified to support the sustainable application of FRCAC in marine infrastructure.
- Open Access
Experimental Study on Shear Performance of Longitudinal Joints in Prefabricated Invert Arch for Mountain Mining Method Tunnels
In order to improve the efficiency of highway tunnel construction and ensure the construction quality, the design concept of a prefabricated inverted arch and partial cast-in-place lining of highway tunnels by a mining method is put forward. During the assembly of prefabricated tunnel invert arches, the longitudinal joints between adjacent invert sections were subjected to shear forces due to the combined effects of the invert’s self-weight and construction equipment loads. This study investigated the shear performance of these longitudinal joints under construction loads, with a particular focus on the influence of bolt-tightening torque. Three longitudinal joint specimens were designed and fabricated, varying the bolt-tightening torque as a key parameter, and subjected to shear tests. The failure modes, load–slip behavior, and shear capacity of the joints were analyzed in relation to the tightening torque of high-strength bolts. The results indicate that when the bolt-tightening torque was set to 50% and 70% of the standard torque, the upper bolts of the joint sheared off, while the threads of the lower bolts were damaged. When the torque reached the standard value, all bolts were sheared off. The ultimate shear capacity of the longitudinal joints increased with higher bolt-tightening torque, with the optimal torque range identified as 70% to 85% of the specified standard. Ultimately, a method of calculation for evaluating the shear-bearing capacity of inverted arch longitudinal joints was proposed, with computational outcomes demonstrating a conservative bias that aligns with structural safety requirements.
Open AccessExperimental Study on Shear Performance of Longitudinal Joints in Prefabricated Invert Arch for Mountain Mining Method Tunnels
In order to improve the efficiency of highway tunnel construction and ensure the construction quality, the design concept of a prefabricated inverted arch and partial cast-in-place lining of highway tunnels by a mining method is put forward. During the assembly of prefabricated tunnel invert arches, the longitudinal joints between adjacent invert sections were subjected to shear forces due to the combined effects of the invert’s self-weight and construction equipment loads. This study investigated the shear performance of these longitudinal joints under construction loads, with a particular focus on the influence of bolt-tightening torque. Three longitudinal joint specimens were designed and fabricated, varying the bolt-tightening torque as a key parameter, and subjected to shear tests. The failure modes, load–slip behavior, and shear capacity of the joints were analyzed in relation to the tightening torque of high-strength bolts. The results indicate that when the bolt-tightening torque was set to 50% and 70% of the standard torque, the upper bolts of the joint sheared off, while the threads of the lower bolts were damaged. When the torque reached the standard value, all bolts were sheared off. The ultimate shear capacity of the longitudinal joints increased with higher bolt-tightening torque, with the optimal torque range identified as 70% to 85% of the specified standard. Ultimately, a method of calculation for evaluating the shear-bearing capacity of inverted arch longitudinal joints was proposed, with computational outcomes demonstrating a conservative bias that aligns with structural safety requirements.