David Shin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David Shin has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Olumide Danisa
Department of Orthopaedic Surgery and Neurosurgery, Duke University Medical Center, Durham, NC 27710, USA
2 shared publications Taha M. Taka
2 shared publicationsAlexander Bouterse
1 shared publicationAndrew Cabrera
1 shared publication- Andrew Miner
School of Medicine, Loma Linda University, Loma Linda, USA
1 shared publication Brandon Shin
Department of Surgery, University of California Davis Medical Center, Sacramento, USA
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 27
Risk Stratification for Postoperative Hematoma Following Anterior Cervical Spine Surgery: A Machine Learning Approach
- 1 June 2026
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 27
Open AccessRisk Stratification for Postoperative Hematoma Following Anterior Cervical Spine Surgery: A Machine Learning Approach
- Open Access
- 5 January 2026
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 48 (1) , 32
Anatomic parameters for diagnosing congenital cervical stenosis via computed tomography
Purpose: To establish parameters for congenital cervical stenosis (CCS) using computed tomography (CT), assessing influences of patient sex, race, and ethnicity. Methods: Measurements were collected of anteroposterior diameter (APD), interpedicular distance (IPD) and cervical intervertebral foramen dimensions (CIFD) from 1000 patients between 18 and 35 years of age without spinal pathology. CCS was determined as two standard deviations below the mean of the collected measurements. Results: Irrespective of vertebral level, mean anatomic APD, CIFD and IPD measurements were as follows: 14.94 ± 1.99 mm for APD, 6.58 ± 1.45 mm and 6.68 ± 1.45 mm for left and right widths, of 9.30 ± 2.30 mm and 9.25 ± 2.80 mm for left and right heights, 57.0 ± 19.2 mm 2 and 59.5 ± 20.3 mm 2 for left and right areas, and 25.4 ± 1.78 mm for IPD. Irrespective of vertebral level, threshold values for CCS were 10.96 mm for APD, 3.68 mm and 3.78 mm for left and right widths, of 4.70 mm and 3.65 mm for left and right heights, 20.6 mm 2 and 19 mm 2 for left and right areas, and 21.8 mm for IPD. Males demonstrated larger CCS threshold values than females for left and right CIFD area and APD. African American patients had smaller CIFDs and APD, and subsequent CCS thresholds compared to White patients. Conclusions: This study reports measurements of CIFD, IPD, and APD to establish quantitative thresholds for diagnosis of CCS. CCS thresholds were significantly influenced by patient sex, race, and ethnicity.
- 5 January 2026
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 48 (1) , 32
Open AccessAnatomic parameters for diagnosing congenital cervical stenosis via computed tomography
Purpose: To establish parameters for congenital cervical stenosis (CCS) using computed tomography (CT), assessing influences of patient sex, race, and ethnicity. Methods: Measurements were collected of anteroposterior diameter (APD), interpedicular distance (IPD) and cervical intervertebral foramen dimensions (CIFD) from 1000 patients between 18 and 35 years of age without spinal pathology. CCS was determined as two standard deviations below the mean of the collected measurements. Results: Irrespective of vertebral level, mean anatomic APD, CIFD and IPD measurements were as follows: 14.94 ± 1.99 mm for APD, 6.58 ± 1.45 mm and 6.68 ± 1.45 mm for left and right widths, of 9.30 ± 2.30 mm and 9.25 ± 2.80 mm for left and right heights, 57.0 ± 19.2 mm 2 and 59.5 ± 20.3 mm 2 for left and right areas, and 25.4 ± 1.78 mm for IPD. Irrespective of vertebral level, threshold values for CCS were 10.96 mm for APD, 3.68 mm and 3.78 mm for left and right widths, of 4.70 mm and 3.65 mm for left and right heights, 20.6 mm 2 and 19 mm 2 for left and right areas, and 21.8 mm for IPD. Males demonstrated larger CCS threshold values than females for left and right CIFD area and APD. African American patients had smaller CIFDs and APD, and subsequent CCS thresholds compared to White patients. Conclusions: This study reports measurements of CIFD, IPD, and APD to establish quantitative thresholds for diagnosis of CCS. CCS thresholds were significantly influenced by patient sex, race, and ethnicity.
- Open Access
- 25 June 2025
- Published by Springer Nature in European Spine Journal
- p. 1-10
The role of generative artificial intelligence in deciding fusion treatment of lumbar degeneration: a comparative analysis and narrative review
Purpose: This study analyzed responses and readability of generative artificial intelligence (AI) models to questions and recommendations from the 2014 Journal of Neurosurgery: Spine (JNS) guidelines for fusion procedures in the treatment of degenerative lumbar spine disease. Methods: Twenty-four questions were generated from JNS guidelines and asked to ChatGPT 4o, Perplexity, Microsoft Copilot, and Gemini. Answers were “concordant” if the response highlighted all points from the JNS guidelines; otherwise, answers were considered “non-concordant” and further sub-categorized as either “insufficient” or “overconclusive.” Responses were evaluated for readability via the Flesch–Kincaid Grade Level, Gunning Fog Index, Simple Measure of Gobbledygook (SMOG) Index, and Flesch Reading Ease test. Results: ChatGPT 4o had the highest concordance rate at 66.67%, with non-concordant responses distributed at 16.67% for both insufficient and over-conclusive classifications. Perplexity displayed a 58.33% concordance rate, with 25% insufficient and 16.67% over-conclusive responses. Copilot showed 50% concordance, with 37.5% over-conclusive and 16.67% insufficient responses. Gemini demonstrated 54.17% concordance, with 20.83% insufficient and 25% over-conclusive responses. The Flesch–Kincaid Grade Level scores ranged from 14.03 (Copilot) to 15.66 (Perplexity). The Gunning Fog Index scores varied between 15.15 (Copilot) and 18.13 (Perplexity). The SMOG Index scores ranged from 14.69 (Copilot) to 16.49 (Perplexity). The Flesch Reading Ease scores were low across all models, with Copilot showing the highest score of 20.71. Conclusions: ChatGPT 4.0 emerged as the best-performing model in terms of concordance, while Perplexity displayed the highest complexity in text readability. AI can be a valuable adjunct in clinical decision-making but cannot replace clinician judgment.
- 25 June 2025
- Published by Springer Nature in European Spine Journal
- p. 1-10
Open AccessThe role of generative artificial intelligence in deciding fusion treatment of lumbar degeneration: a comparative analysis and narrative review
Purpose: This study analyzed responses and readability of generative artificial intelligence (AI) models to questions and recommendations from the 2014 Journal of Neurosurgery: Spine (JNS) guidelines for fusion procedures in the treatment of degenerative lumbar spine disease. Methods: Twenty-four questions were generated from JNS guidelines and asked to ChatGPT 4o, Perplexity, Microsoft Copilot, and Gemini. Answers were “concordant” if the response highlighted all points from the JNS guidelines; otherwise, answers were considered “non-concordant” and further sub-categorized as either “insufficient” or “overconclusive.” Responses were evaluated for readability via the Flesch–Kincaid Grade Level, Gunning Fog Index, Simple Measure of Gobbledygook (SMOG) Index, and Flesch Reading Ease test. Results: ChatGPT 4o had the highest concordance rate at 66.67%, with non-concordant responses distributed at 16.67% for both insufficient and over-conclusive classifications. Perplexity displayed a 58.33% concordance rate, with 25% insufficient and 16.67% over-conclusive responses. Copilot showed 50% concordance, with 37.5% over-conclusive and 16.67% insufficient responses. Gemini demonstrated 54.17% concordance, with 20.83% insufficient and 25% over-conclusive responses. The Flesch–Kincaid Grade Level scores ranged from 14.03 (Copilot) to 15.66 (Perplexity). The Gunning Fog Index scores varied between 15.15 (Copilot) and 18.13 (Perplexity). The SMOG Index scores ranged from 14.69 (Copilot) to 16.49 (Perplexity). The Flesch Reading Ease scores were low across all models, with Copilot showing the highest score of 20.71. Conclusions: ChatGPT 4.0 emerged as the best-performing model in terms of concordance, while Perplexity displayed the highest complexity in text readability. AI can be a valuable adjunct in clinical decision-making but cannot replace clinician judgment.