JWJiayin Wang

Jiayin Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiayin Wang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • VisionSafeEnhanced VPC: Cautious Predictive Control With Visibility Constraints Under Uncertainty for Autonomous Robotic Surgery

    by Jiayin Wang, Yanran Wei, Lei Jiang, Xiaoyu Guo, Ayong Zheng, Weidong Zhao, Zhongkui Li

    Autonomous control of the laparoscope in robot-assisted Minimally Invasive Surgery (MIS) has received considerable research interest due to its potential to improve surgical safety. Despite progress in pixel-level Image-Based Visual Servoing (IBVS) control, the requirement of continuous visibility and the existence of complex disturbances, such as parameterization error, measurement noise, and uncertainties of payloads, could degrade the surgeon’s visual experience and compromise procedural safety. To address these limitations, this letter proposes VisionSafeEnhanced Visual Predictive Control (VPC), a robust and uncertainty-adaptive framework that guarantees Field of View (FoV) safety under uncertainty. Firstly, Gaussian Process Regression (GPR) is utilized to perform hybrid quantification of operational uncertainties including residual model uncertainties, stochastic uncertainties, and external disturbances. Based on uncertainty quantification, a novel safety-aware trajectory optimization framework with probabilistic guarantees is proposed, where an uncertainty-adaptive safety Control Barrier Function (CBF) condition is given based on uncertainty propagation, and chance constraints are simultaneously formulated based on probabilistic approximation. This uncertainty aware formulation enables adaptive control effort allocation, minimizing unnecessary camera motion while maintaining robustness. The proposed method is validated through comparative simulations and experiments on a commercial surgical robot platform (MicroPort MedBot Toumai) performing a sequential multi-target lymph node dissection. Compared with baseline methods, the framework maintains near-perfect target visibility ($> 99.9\%$), reduces tracking errors by over 77% under uncertainty, and lowers control effort by more than an order of magnitude.


  • Open Access

    Automatic cutting and suturing control system based on improved FP16 visual recognition algorithm

    by Jiayin Wang, Weidong Zhao

    Objective: This study aims to develop and evaluate an autonomous surgical system based on the Toumai laparoscopic surgical robot, focusing on improving the precision and reliability of automated cutting and suturing operations. Methods: The proposed system integrates several key components: (1) Robotic arms and associated control systems. (2) An endoscopic system supporting advanced visual image algorithms. (3) Specialized surgical instruments for cutting and suturing. A binocular stereo matching algorithm is employed to obtain depth information from the field of binocular camera. The DarkPose image key point localization algorithm and the Yolov5 image detection algorithm are utilized to accurately determine the positions of surgical instruments, suture needles, and target points. Additionally, an image classification discriminator is introduced to assess the success of the surgical tasks. A finite state machine model is used to guide the robotic arm's end-effector through real-time trajectory planning and execution, ensuring precise completion of surgical tasks. Results: Experimental evaluation demonstrated that the autonomous system achieves high precision and reliability in both cutting and suturing tasks. Quantitative analysis shows that the system maintains an 85% success rate in automatic cutting, with a mean time of 5.10 s per cutting action. The automatic suturing task achieves a 92% accuracy rate in instrument positioning and a 90% success rate in needle grasping. Conclusion: The developed system shows significant promise in automating key laparoscopic surgical tasks, with the potential to enhance surgical efficiency and improve outcomes in clinical practice. Further development and validation of this system could lead to its broader adoption in the field of autonomous surgery.

  • Image-to-Force Estimation for Soft Tissue Interaction in Robotic-Assisted Surgery Using Structured Light

    by Jiayin Wang, Mingfeng Yao, Yanran Wei, Xiaoyu Guo, Ayong Zheng, Weidong Zhao

    For Minimally Invasive Surgical (MIS) robots, accurate haptic interaction force feedback is essential for ensuring the safety of interacting with soft tissue. However, the majority of existing MIS robotic systems cannot facilitate direct measurement of the interaction force with hardware sensors due to space limitations. This letter introduces an effective vision-based scheme that utilizes a One-Shot structured light projection with a designed pattern on soft tissue coupled with haptic information processing through a trained image-to-force neural network. The images captured from the endoscopic stereo camera are analyzed to reconstruct high-resolution 3D point clouds for soft tissue deformation. The proposed methodology involves a modified PointNet-based force estimation method, which has demonstrated proficiency in accurately representing the intricate mechanical properties of soft tissue. To validate the efficacy of the proposed methodology, numerical force interaction experiments were conducted on three silicon materials with varying stiffness levels. The experimental results substantiate the efficacy of the proposed methodology.