Latest Publications
- 9 September 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (36) , 365501
High-pressure chemiluminescence diagnostics in an axisymmetric constant volume combustion bomb with synchronized axial ignition
To investigate the chemiluminescence characteristics of high-pressure premixed combustion of hydrocarbon fuels, a cylindrical constant-volume combustion bomb with axially synchronized ignition was designed in this study. First, high-frequency imaging was employed to perform high-dynamic measurements of the flame front propagation process during axially ignited combustion. The results show a uniform axial distribution of chemiluminescence intensity, confirming the feasibility of conducting spectral measurements along the axial direction. On this basis, using time-resolved broadband spectral data, significant differences in the OH* and CH* chemiluminescence intensities were observed between the flame front and post-flame regions. Through calibration experiments, the spectral data were converted into quantitative chemiluminescence intensity data at the flame front. Then, based on the correlation between the OH*/CH* chemiluminescence intensity ratio and pressure, a path-integrated equivalence-ratio diagnostic model for high-pressure combustion was established within the pressure range of 5–14 bar. Additionally, to address the challenge of temperature measurement under transient high-pressure combustion conditions, a method based on blackbody radiation and chemiluminescence spectral separation was proposed. Using the blackbody radiation generated from the vaporization of the axial ignition wire, transient temperature measurement in high-pressure premixed combustion was achieved. The measured temperatures show good agreement with simulation results, with deviations of less than 10%.
- 9 September 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (36) , 365501
High-pressure chemiluminescence diagnostics in an axisymmetric constant volume combustion bomb with synchronized axial ignition
To investigate the chemiluminescence characteristics of high-pressure premixed combustion of hydrocarbon fuels, a cylindrical constant-volume combustion bomb with axially synchronized ignition was designed in this study. First, high-frequency imaging was employed to perform high-dynamic measurements of the flame front propagation process during axially ignited combustion. The results show a uniform axial distribution of chemiluminescence intensity, confirming the feasibility of conducting spectral measurements along the axial direction. On this basis, using time-resolved broadband spectral data, significant differences in the OH* and CH* chemiluminescence intensities were observed between the flame front and post-flame regions. Through calibration experiments, the spectral data were converted into quantitative chemiluminescence intensity data at the flame front. Then, based on the correlation between the OH*/CH* chemiluminescence intensity ratio and pressure, a path-integrated equivalence-ratio diagnostic model for high-pressure combustion was established within the pressure range of 5–14 bar. Additionally, to address the challenge of temperature measurement under transient high-pressure combustion conditions, a method based on blackbody radiation and chemiluminescence spectral separation was proposed. Using the blackbody radiation generated from the vaporization of the axial ignition wire, transient temperature measurement in high-pressure premixed combustion was achieved. The measured temperatures show good agreement with simulation results, with deviations of less than 10%.
- 26 June 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (7) , 075502
Accurate evaluation of equivalence ratio effect on chemiluminescence spectroscopy in hydrocarbon fuel flames: experimental measurement and numerical validation
Herein, experimental and numerical studies were conducted on the excited-state radicals CO2 *, CH*, OH*, and C2 * in hydrocarbon combustion. In the experiment, an optical fiber spectrometer was employed to perform one-dimensional scanning measurements of chemiluminescent signals in methane/air laminar premixed flames with equivalence ratios ranging from 0.7 to 1.2, capturing the emission spectra of the excited-state radicals. Based on the Abel tomographic reconstruction method, the relationships between the peak chemiluminescence intensity, the peak chemiluminescence intensity ratios, and equivalence ratios of the excited-state radicals were quantitatively investigated. The findings reveal that CO2 * radiation significantly influences the measurement of the chemiluminescence intensities of OH*, CH*, and C2 *. The CO2 * emission interference is quantitatively decoupled through spectral deconvolution, enabling a novel chemiluminescence-based equivalence ratio diagnostic. Calibrated against premixed flames, the C2 */OH* and CH*/OH* intensity ratios exhibit monotonic correlations with equivalence ratios in 0.7–0.9 and 0.9–1.2 regimes, respectively. Finally, the existing chemical reaction mechanisms for OH*, CH*, and C2 * were validated based on the experimental results. It mainly focuses on the relationship between the peak chemiluminescence intensity, the peak chemiluminescence intensity ratios, and the equivalence ratios. Among the existing reaction mechanisms for excited-state radicals, the simulation accuracy for CH* is the highest, while further research is required to refine the chemical reaction mechanisms for OH* and C2 *.
- 26 June 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (7) , 075502
Accurate evaluation of equivalence ratio effect on chemiluminescence spectroscopy in hydrocarbon fuel flames: experimental measurement and numerical validation
Herein, experimental and numerical studies were conducted on the excited-state radicals CO2 *, CH*, OH*, and C2 * in hydrocarbon combustion. In the experiment, an optical fiber spectrometer was employed to perform one-dimensional scanning measurements of chemiluminescent signals in methane/air laminar premixed flames with equivalence ratios ranging from 0.7 to 1.2, capturing the emission spectra of the excited-state radicals. Based on the Abel tomographic reconstruction method, the relationships between the peak chemiluminescence intensity, the peak chemiluminescence intensity ratios, and equivalence ratios of the excited-state radicals were quantitatively investigated. The findings reveal that CO2 * radiation significantly influences the measurement of the chemiluminescence intensities of OH*, CH*, and C2 *. The CO2 * emission interference is quantitatively decoupled through spectral deconvolution, enabling a novel chemiluminescence-based equivalence ratio diagnostic. Calibrated against premixed flames, the C2 */OH* and CH*/OH* intensity ratios exhibit monotonic correlations with equivalence ratios in 0.7–0.9 and 0.9–1.2 regimes, respectively. Finally, the existing chemical reaction mechanisms for OH*, CH*, and C2 * were validated based on the experimental results. It mainly focuses on the relationship between the peak chemiluminescence intensity, the peak chemiluminescence intensity ratios, and the equivalence ratios. Among the existing reaction mechanisms for excited-state radicals, the simulation accuracy for CH* is the highest, while further research is required to refine the chemical reaction mechanisms for OH* and C2 *.