Benjamin Mueller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Benjamin Mueller has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Rui Guo
Digital Solutions, Intuitive Surgical Inc., Peachtree Corners, USA
2 shared publications - Anthony M. Jarc
Digital Solutions, Intuitive Surgical, Peachtree Corners, USA
1 shared publication - Busisiwe Mlambo
Intuitive Surgical, Sunnyvale, USA
1 shared publication - Conor Perreault
Digital Solutions, Intuitive Surgical, Peachtree Corners, USA
1 shared publication - Rogerio Nespolo
Digital Solutions, Intuitive Surgical Inc., Peachtree Corners, USA
1 shared publication - Sue Kulason
Intuitive Surgical, Sunnyvale, USA
1 shared publication
Latest Publications
- Open Access
- 12 September 2025
- Published by Springer Nature in Surgical Endoscopy
- Vol. 39 (11) , 7707-7712
Development of anatomical metrics for objective quantification of critical view of safety
Background Debates on the subjective criteria for evaluating Surgical Milestones, such as achieving the critical view of safety (CVS) during cholecystectomy, remain a prominent focus and challenge in the field of surgical data science. In this study, we computed anatomical metrics with machine learning tools and investigated the relationship between these objective anatomical metrics and subjective criteria for CVS achievement. Methods We implemented and calibrated a zero-shot monocular depth estimation model for endoscopic images from cholecystectomies. These depth measures were integrated with human-annotated segmentation masks of three key anatomical structures relevant to CVS: cystic duct, cystic artery, and gallbladder. Computational geometry techniques were then employed to extract structure-specific depth distributions and compute two anatomical metrics: diagonal length and surface area. We tested for significant differences in these case-wise metrics, grouped by human-annotated CVS status. Results 2256 frames (35 cases) were graded on CVS criteria, of which 343 frames (17 cases) met all three CVS criteria and 384 frames (17 cases) met no CVS criteria. The calibrated depth model achieves 0.063 on absolute relative error and 0.774 on squared relative error in the metric measurement. The diagonal length and surface area of both the cystic duct and cystic artery were significantly larger when all CVS criteria were met. On average, the cystic duct (cystic artery) length was 7.6 mm (13.6 mm) longer when CVS criteria was met. Conclusion In this study, we presented a pipeline that generates anatomical measures from monocular endoscopic images utilizing a depth estimation model, anatomical segmentation masks, and computational geometry. The diagonal length and surface area of the cystic duct and cystic artery were found to be significantly larger in cases where all CVS criteria are met; this lends support to the use of these anatomical metrics as objective grounds for assessing CVS achievement.
- 12 September 2025
- Published by Springer Nature in Surgical Endoscopy
- Vol. 39 (11) , 7707-7712
Open AccessDevelopment of anatomical metrics for objective quantification of critical view of safety
Background Debates on the subjective criteria for evaluating Surgical Milestones, such as achieving the critical view of safety (CVS) during cholecystectomy, remain a prominent focus and challenge in the field of surgical data science. In this study, we computed anatomical metrics with machine learning tools and investigated the relationship between these objective anatomical metrics and subjective criteria for CVS achievement. Methods We implemented and calibrated a zero-shot monocular depth estimation model for endoscopic images from cholecystectomies. These depth measures were integrated with human-annotated segmentation masks of three key anatomical structures relevant to CVS: cystic duct, cystic artery, and gallbladder. Computational geometry techniques were then employed to extract structure-specific depth distributions and compute two anatomical metrics: diagonal length and surface area. We tested for significant differences in these case-wise metrics, grouped by human-annotated CVS status. Results 2256 frames (35 cases) were graded on CVS criteria, of which 343 frames (17 cases) met all three CVS criteria and 384 frames (17 cases) met no CVS criteria. The calibrated depth model achieves 0.063 on absolute relative error and 0.774 on squared relative error in the metric measurement. The diagonal length and surface area of both the cystic duct and cystic artery were significantly larger when all CVS criteria were met. On average, the cystic duct (cystic artery) length was 7.6 mm (13.6 mm) longer when CVS criteria was met. Conclusion In this study, we presented a pipeline that generates anatomical measures from monocular endoscopic images utilizing a depth estimation model, anatomical segmentation masks, and computational geometry. The diagonal length and surface area of the cystic duct and cystic artery were found to be significantly larger in cases where all CVS criteria are met; this lends support to the use of these anatomical metrics as objective grounds for assessing CVS achievement.
- Open Access
- 26 June 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (1) , 153-161
Dual-task meta-auxiliary learning in laparoscopic cholecystectomy
Purpose: Artificial intelligence is transforming surgical practices by improving procedural quality and decision-making. Machine learning-based video analysis can reliably identify surgical milestones, enhancing contextual understanding for surgeons. This study proposes a novel framework for detecting critical view of safety (CVS) in robot-assisted laparoscopic cholecystectomy (RLC) to improve procedural safety. Methods: We present a meta-auxiliary learning framework that delicately combines milestone recognition and anatomical segmentation to enhance contextual awareness. The framework addresses label imbalance by facilitating knowledge sharing across tasks, ensuring balanced optimization. A curated RLC dataset was utilized to evaluate CVS identification and multi-instance segmentation performance. Results: The proposed method achieved an F1 score of 78% for CVS detection and a mean IOU of 83.9% for anatomical segmentation, demonstrating its efficacy in complex surgical environments. Conclusion: This framework establishes a new paradigm for surgical video analysis by integrating milestone detection and segmentation. Its ability to enhance decision support and procedural review in RLC highlights its potential for broader adoption in clinical practice.
- 26 June 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (1) , 153-161
Open AccessDual-task meta-auxiliary learning in laparoscopic cholecystectomy
Purpose: Artificial intelligence is transforming surgical practices by improving procedural quality and decision-making. Machine learning-based video analysis can reliably identify surgical milestones, enhancing contextual understanding for surgeons. This study proposes a novel framework for detecting critical view of safety (CVS) in robot-assisted laparoscopic cholecystectomy (RLC) to improve procedural safety. Methods: We present a meta-auxiliary learning framework that delicately combines milestone recognition and anatomical segmentation to enhance contextual awareness. The framework addresses label imbalance by facilitating knowledge sharing across tasks, ensuring balanced optimization. A curated RLC dataset was utilized to evaluate CVS identification and multi-instance segmentation performance. Results: The proposed method achieved an F1 score of 78% for CVS detection and a mean IOU of 83.9% for anatomical segmentation, demonstrating its efficacy in complex surgical environments. Conclusion: This framework establishes a new paradigm for surgical video analysis by integrating milestone detection and segmentation. Its ability to enhance decision support and procedural review in RLC highlights its potential for broader adoption in clinical practice.