M. Jára
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
M. Jára has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Benedikt Bergmann
Czech Technical University in Prague
1 shared publication - Martin Farkas
Faculty of Electrical Engineering, University of West Bohemia, Univerzitní 26, Pilsen, Czech Republic
1 shared publication - Ondrej Ruzicka
Faculty of Electrical Engineering, University of West Bohemia, Univerzitní 8, 301 00 Pilsen, Czech Republic
1 shared publication - Pavel Broulim
Faculty of Electrical Engineering, University of West Bohemia, Univerzitní 8, 301 00 Pilsen, Czech Republic
1 shared publication - Petr Burian
Institute of Experimental and Applied Physics, Czech Technical University in Prague, Prague, Czech Republic
1 shared publication - Petr Mánek
Institute of Experimental and Applied Physics, Czech Technical University in Prague, Prague, Czech Republic
1 shared publication
Latest Publications
- Open Access
- 1 June 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (06) , C06077
Katherine Generation 2: advanced readout system for Timepix3 detectors
This paper presents Katherine Generation 2 (Gen2), an advanced readout system designed for Timepix3 pixel detector. The new system addresses limitations of the original Katherine (Gen1) design, particularly in terms of data throughput and support for multi-detector configurations. Katherine Gen2 supports two sensor inputs via VHDCI connectors and provides two independent bias voltage sources up to ±1 kV. It includes both Gigabit Ethernet and USB 3.0 interfaces, offering flexibility for remote or local high-throughput applications. Data handling pipeline has been extended to support dynamic detector mapping, hardware decoding of pixel data, and timestamping of external triggers. Compatibility with multiple chipboard types, including single-chip, quad (2× 2), and specialized detector units, is maintained. Benchmark measurements demonstrate that the system achieves the maximum data rate supported by the Timepix3 chip in USB 3.0 mode. The device is supported by established software tools and is intended as a flexible platform for various experimental and detector development applications.
- 1 June 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (06) , C06077
Open AccessKatherine Generation 2: advanced readout system for Timepix3 detectors
This paper presents Katherine Generation 2 (Gen2), an advanced readout system designed for Timepix3 pixel detector. The new system addresses limitations of the original Katherine (Gen1) design, particularly in terms of data throughput and support for multi-detector configurations. Katherine Gen2 supports two sensor inputs via VHDCI connectors and provides two independent bias voltage sources up to ±1 kV. It includes both Gigabit Ethernet and USB 3.0 interfaces, offering flexibility for remote or local high-throughput applications. Data handling pipeline has been extended to support dynamic detector mapping, hardware decoding of pixel data, and timestamping of external triggers. Compatibility with multiple chipboard types, including single-chip, quad (2× 2), and specialized detector units, is maintained. Benchmark measurements demonstrate that the system achieves the maximum data rate supported by the Timepix3 chip in USB 3.0 mode. The device is supported by established software tools and is intended as a flexible platform for various experimental and detector development applications.