Maoqiang Wang
Maoqiang Wang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Bin Liu
Research Institute of Urbanization and Urban Safety, School of Future Cities, University of Science and Technology Beijing, Beijing 100083, China
1 shared publication - Huaimao Yang
CCCC Highway Bridges National Engineering Research Centre, Ltd., Beijing 100120, China
1 shared publication - Jianwen Li
Research Institute of Urbanization and Urban Safety, School of Future Cities, University of Science and Technology Beijing, Beijing 100083, China
1 shared publication - Kaijie Huang
School of Architecture and Civil Engineering, Xi’an University of Science and Technology, No. 58 Yanta Rd., Xi’an 710054, China
1 shared publication - Lili Hu
University of Science and Technology Beijing
1 shared publication - Qian Wu
School of Highway, Chang’an University, Middle of the South Second Ring, Xi’an 710065, China
1 shared publication
Latest Publications
- Open Access
- 26 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 279
Analytical Calculation Method for Anti-Slip of Main Cables in Three-Tower Suspension Bridges with Spatial Cable Systems
To investigate the anti-slip characteristics of the main cables in a three-tower suspension bridge with spatial cable systems, this paper proposes an analytical calculation method for the anti-slip safety factor of the main cables and establishes an equivalent mechanical analysis model for multi-tower suspension bridges with spatial cable systems. Based on the deformation of the towers and cables under live load, as well as the equilibrium relationship of the main cable forces in loaded and unloaded spans, analytical formulas for the anti-slip safety factor of the main cables at the middle tower saddle are derived. A finite element model is developed to validate the formulas. The influence of parameters such as the spatial cable inclination angle, tower-to-cable stiffness ratio, dead-to-live load ratio, sag-to-span ratio, span length, and friction coefficient between the main cable and saddle on the anti-slip safety factor is analyzed. The results indicate that the formula proposed in this paper provides a highly accurate estimation of the slip resistance safety factor for main cables in spatial cable multi-tower suspension bridges. The adoption of spatial main cable configuration enhances the stability of the slip resistance safety factor at the intermediate tower saddle. The slip resistance safety factor of the main cable decreases with the increase in the tower-to-cable stiffness ratio, while it increases with the rise in the sag-to-span ratio. Moreover, the influence of the sag-to-span ratio on the slip resistance stability of the main cable becomes more pronounced with higher tower stiffness. The slip resistance safety factor of the main cable exhibits an approximately linear increase with the rise in the dead-to-live load ratio and the coefficient of friction. Furthermore, the slip resistance safety factor increases with the span length, and this rate of increase becomes more pronounced with smaller sag-to-span ratios. The research findings presented in this paper provide a theoretical basis for the design of spatial cable multi-tower suspension bridges.
- 26 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 279
Open AccessAnalytical Calculation Method for Anti-Slip of Main Cables in Three-Tower Suspension Bridges with Spatial Cable Systems
To investigate the anti-slip characteristics of the main cables in a three-tower suspension bridge with spatial cable systems, this paper proposes an analytical calculation method for the anti-slip safety factor of the main cables and establishes an equivalent mechanical analysis model for multi-tower suspension bridges with spatial cable systems. Based on the deformation of the towers and cables under live load, as well as the equilibrium relationship of the main cable forces in loaded and unloaded spans, analytical formulas for the anti-slip safety factor of the main cables at the middle tower saddle are derived. A finite element model is developed to validate the formulas. The influence of parameters such as the spatial cable inclination angle, tower-to-cable stiffness ratio, dead-to-live load ratio, sag-to-span ratio, span length, and friction coefficient between the main cable and saddle on the anti-slip safety factor is analyzed. The results indicate that the formula proposed in this paper provides a highly accurate estimation of the slip resistance safety factor for main cables in spatial cable multi-tower suspension bridges. The adoption of spatial main cable configuration enhances the stability of the slip resistance safety factor at the intermediate tower saddle. The slip resistance safety factor of the main cable decreases with the increase in the tower-to-cable stiffness ratio, while it increases with the rise in the sag-to-span ratio. Moreover, the influence of the sag-to-span ratio on the slip resistance stability of the main cable becomes more pronounced with higher tower stiffness. The slip resistance safety factor of the main cable exhibits an approximately linear increase with the rise in the dead-to-live load ratio and the coefficient of friction. Furthermore, the slip resistance safety factor increases with the span length, and this rate of increase becomes more pronounced with smaller sag-to-span ratios. The research findings presented in this paper provide a theoretical basis for the design of spatial cable multi-tower suspension bridges.
- Open Access
Effects of Stress Level and Elevated Temperature on Transverse Compression Stress Relaxation Behavior and Post-Relaxation Mechanical Performance of UD-CFRP
Unidirectional carbon fiber-reinforced polymer (UD-CFRP) composites demonstrate superior tensile creep strain and stress relaxation behavior along fiber orientation. However, prolonged transverse compressive loading in structural connection zones induces significant interfacial stress relaxation and creep deformation, primarily driven by resin matrix degradation and interfacial slippage under thermal-mechanical interactions, and remains poorly understood. This study systematically investigates the transverse stress relaxation characteristics of UD-CFRP through controlled experiments under varying thermal conditions (20–80 °C) and compressive stress levels (30–80% ultimate strength). Post-relaxation mechanical properties were quantitatively evaluated, followed by the development of a temperature-stress-time-dependent predictive model aligned with industry standards. The experimental results reveal bi-stage relaxation behavior under elevated temperatures and compressive stresses, characterized by a rapid primary phase and stabilized secondary phase progression. Notably, residual transverse compressive strength remained almost unchanged, while post-relaxation elastic modulus increased by around 10% compared to baseline specimens. Predictive modeling indicates that million-hour relaxation rates escalate with temperature elevation, reaching 51% at 60 °C/60% stress level—about 1.8 times higher than equivalent 20 °C conditions. These findings provide crucial design insights and predictive tools for ensuring the long-term integrity of CFRP-based structures subjected to transverse compression in various thermal environments.
Open AccessEffects of Stress Level and Elevated Temperature on Transverse Compression Stress Relaxation Behavior and Post-Relaxation Mechanical Performance of UD-CFRP
Unidirectional carbon fiber-reinforced polymer (UD-CFRP) composites demonstrate superior tensile creep strain and stress relaxation behavior along fiber orientation. However, prolonged transverse compressive loading in structural connection zones induces significant interfacial stress relaxation and creep deformation, primarily driven by resin matrix degradation and interfacial slippage under thermal-mechanical interactions, and remains poorly understood. This study systematically investigates the transverse stress relaxation characteristics of UD-CFRP through controlled experiments under varying thermal conditions (20–80 °C) and compressive stress levels (30–80% ultimate strength). Post-relaxation mechanical properties were quantitatively evaluated, followed by the development of a temperature-stress-time-dependent predictive model aligned with industry standards. The experimental results reveal bi-stage relaxation behavior under elevated temperatures and compressive stresses, characterized by a rapid primary phase and stabilized secondary phase progression. Notably, residual transverse compressive strength remained almost unchanged, while post-relaxation elastic modulus increased by around 10% compared to baseline specimens. Predictive modeling indicates that million-hour relaxation rates escalate with temperature elevation, reaching 51% at 60 °C/60% stress level—about 1.8 times higher than equivalent 20 °C conditions. These findings provide crucial design insights and predictive tools for ensuring the long-term integrity of CFRP-based structures subjected to transverse compression in various thermal environments.
- Open Access
Static and Dynamic Performance of Long-Span Suspension Bridges with Flexible CFRP Central Buckles
The central buckle is essential for maintaining longitudinal stability in suspension bridges. However, conventional steel buckles are often excessively stiff, leading to stress concentration and insufficient durability. Moreover, they tend to perform poorly under fatigue loading conditions. This study proposes a novel flexible central buckle system based on a Carbon Fiber-Reinforced Polymer (CFRP) to address these limitations. This study proposes a novel flexible central buckle system based on Carbon Fiber-Reinforced Polymer (CFRP) to address these limitations. Taking the long-span Shiziyang Suspension Bridge as a case study, a finite element model is developed to investigate the effects of CFRP central buckles with eight different stiffness levels on the static and dynamic responses of the bridge. The results indicate that a CFRP central buckle with a low elastic modulus achieves comparable displacement control performance to that of traditional steel buckles, while inducing significantly lower internal forces, demonstrating strong potential as a substitute. Based on this finding, a coordinated control strategy combining the CFRP central buckle with end-span restraining devices is proposed. This integrated system reduces midspan displacement and central buckle internal force by 61.1% and 49.8%, respectively. Considering both performance and cost-efficiency, a low-modulus CFRP material such as T300 is recommended. The proposed approach offers a new and effective solution for longitudinal control in ultra-long-span suspension bridges.
Open AccessStatic and Dynamic Performance of Long-Span Suspension Bridges with Flexible CFRP Central Buckles
The central buckle is essential for maintaining longitudinal stability in suspension bridges. However, conventional steel buckles are often excessively stiff, leading to stress concentration and insufficient durability. Moreover, they tend to perform poorly under fatigue loading conditions. This study proposes a novel flexible central buckle system based on a Carbon Fiber-Reinforced Polymer (CFRP) to address these limitations. This study proposes a novel flexible central buckle system based on Carbon Fiber-Reinforced Polymer (CFRP) to address these limitations. Taking the long-span Shiziyang Suspension Bridge as a case study, a finite element model is developed to investigate the effects of CFRP central buckles with eight different stiffness levels on the static and dynamic responses of the bridge. The results indicate that a CFRP central buckle with a low elastic modulus achieves comparable displacement control performance to that of traditional steel buckles, while inducing significantly lower internal forces, demonstrating strong potential as a substitute. Based on this finding, a coordinated control strategy combining the CFRP central buckle with end-span restraining devices is proposed. This integrated system reduces midspan displacement and central buckle internal force by 61.1% and 49.8%, respectively. Considering both performance and cost-efficiency, a low-modulus CFRP material such as T300 is recommended. The proposed approach offers a new and effective solution for longitudinal control in ultra-long-span suspension bridges.