Jaromír Kylar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jaromír Kylar has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jan Šleichrt
Czech Academy of Sciences, Institute of Theoretical and Applied Mechanics
3 shared publications - Jan Falta
Department of Mechanics and Materials, Faculty of Transportation Sciences, Czech Technical University in Prague, Na Florenci 25, 110 00 Prague 1, Czech Republic
2 shared publications - Nela Krčmářová
Department of Mechanics and Materials, Faculty of Transportation Sciences Czech Technical University Prague Czech Republic
2 shared publications - Petr Koudelka
Institute of Theoretical and Applied Mechanics, Czech Academy of Sciences, Prague 9, Czech Republic
2 shared publications - Tomáš Fíla
Faculty of Transportation Sciences, Czech Technical University in Prague, Prague, Czechia
2 shared publications - Veronika Drechslerová
Faculty of Transportation Sciences, Czech Technical University in Prague, Prague, Czechia
2 shared publications
Latest Publications
- Open Access
- 18 August 2026
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 15 (3) , 1-7
X-ray computed tomography for non-destructive evaluation of steel wire ropes: Comparison of laboratory XCT configurations for image quality and damage visualization
Steel wire ropes are critical structural components whose internal damage often cannot be reliably assessed using conventional non-destructive testing methods. This study evaluates the applicability of laboratory X-ray computed microtomography (XCT) for detailed inspection of steel wire ropes by comparing three complementary XCT configurations: one employing a liquid-metal anode microfocus source with a large-area flat-panel detector, a conventional sealed-type microfocus tube with CMOS detector, and a high-power X-ray source coupled with scintillating screen and a laboratory camera. Intact and damaged rope specimens together with an individual fractured steel wire were investigated under various acquisition conditions. Image quality was quantitatively assessed using the contrast-to-noise ratio (CNR) and the full width at half maximum (FWHM) of the line spread function, complemented by qualitative evaluation of reconstructed three-dimensional models. The results demonstrate the influence of X-ray source characteristics and the acquisition parameters on image quality and defect detectability. Although the high-power system provided superior penetration capability and the highest CNR, its large focal point substantially limited the achievable spatial resolution. In contrast, both microfocus configurations enabled reliable visualization of individual wires and internal damage features, with image quality strongly dependent on the number of acquired projections. The presented comparison provides practical guidance for selecting appropriate laboratory XCT configurations for non-destructive evaluation of steel wire ropes and similar highly attenuating engineering components.
- 18 August 2026
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 15 (3) , 1-7
Open AccessX-ray computed tomography for non-destructive evaluation of steel wire ropes: Comparison of laboratory XCT configurations for image quality and damage visualization
Steel wire ropes are critical structural components whose internal damage often cannot be reliably assessed using conventional non-destructive testing methods. This study evaluates the applicability of laboratory X-ray computed microtomography (XCT) for detailed inspection of steel wire ropes by comparing three complementary XCT configurations: one employing a liquid-metal anode microfocus source with a large-area flat-panel detector, a conventional sealed-type microfocus tube with CMOS detector, and a high-power X-ray source coupled with scintillating screen and a laboratory camera. Intact and damaged rope specimens together with an individual fractured steel wire were investigated under various acquisition conditions. Image quality was quantitatively assessed using the contrast-to-noise ratio (CNR) and the full width at half maximum (FWHM) of the line spread function, complemented by qualitative evaluation of reconstructed three-dimensional models. The results demonstrate the influence of X-ray source characteristics and the acquisition parameters on image quality and defect detectability. Although the high-power system provided superior penetration capability and the highest CNR, its large focal point substantially limited the achievable spatial resolution. In contrast, both microfocus configurations enabled reliable visualization of individual wires and internal damage features, with image quality strongly dependent on the number of acquired projections. The presented comparison provides practical guidance for selecting appropriate laboratory XCT configurations for non-destructive evaluation of steel wire ropes and similar highly attenuating engineering components.
- Open Access
- 10 April 2026
- Published by Elsevier in Measurement
- Vol. 276
Dual-linear-motor experimental setup for controlled intermediate strain rate testing
- 10 April 2026
- Published by Elsevier in Measurement
- Vol. 276
Open AccessDual-linear-motor experimental setup for controlled intermediate strain rate testing
- Open Access
- 19 June 2025
- Published by Elsevier in International Journal of Impact Engineering
- Vol. 206
Effects of shear thickening fluid filling in additively manufactured sandwich panels during intermediate and high strain rate penetration
- 19 June 2025
- Published by Elsevier in International Journal of Impact Engineering
- Vol. 206
Open AccessEffects of shear thickening fluid filling in additively manufactured sandwich panels during intermediate and high strain rate penetration