Kairat Mendibayev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kairat Mendibayev has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Talgat Issatayev
Joint Institute for Nuclear Research, Dubna, Russia
3 shared publications - Alisher Temirzhanov
The Institute of Nuclear Physics, Almaty, 050032, Kazakhstan
2 shared publications - Sergey Lukyanov
Joint Institute for Nuclear Research
2 shared publications A.M. Zolotarev
Joint Institute for Nuclear Research, Dubna, Russia
1 shared publicationA.V. Shakhov
Joint Institute for Nuclear Research, Dubna, Russia
1 shared publicationAlexey Shahov
1 shared publication
Latest Publications
- Open Access
- 8 September 2026
- Published by CERN in Open Research Europe
Development of high-efficiency micropixel avalanche photodiodes with fast recovery time and enhanced photon detection efficiency
Background Silicon photo-multipliers (SiPMs) suffer from several important limitations, including long recovery time, dead-space losses caused by surface quenching resistors, limited photon detection efficiency (PDE), and saturation effects under high particle flux conditions. These drawbacks significantly restrict detector performance in high-rate timing applications, radiation monitoring systems, and modern scintillation detectors. Methods Novel MAPD structures employing artificial potential micro-wells and intrinsic micro-channel recovery mechanisms were developed using silicon epitaxial technology. Electrical and optical properties of the devices were experimentally investigated through capacitance-voltage measurements, PDE analysis, and recovery-time characterization. Optimized thin-film bilayers of silicon nitride (Si 3N 4) and silicon dioxide (SiO 2) were further implemented as anti-reflection coatings to maximize quantum efficiency (QE). Results The proposed MAPD structure demonstrated substantial improvements compared to conventional structures. The developed devices achieved nearly 100% photosensitive surface coverage, pixel densities up to 2.8 × 10 4 pixels/mm 2, and PDE approaching 40%. Experimental investigations showed that the recovery time was reduced from approximately 300 μs to 40 ns, corresponding to an improvement factor of approximately 7.5 × 10 3. Conclusions The obtained results demonstrate that optimized electric-field engineering combined with intrinsic micro-channel recovery mechanisms significantly improves both PDE and detector recovery dynamics. The proposed structures represent promising candidates for next-generation high-rate silicon photo-detectors intended for fast timing systems, TOF-PET, scintillation detectors, and high-energy physics experiments.
- 8 September 2026
- Published by CERN in Open Research Europe
Open AccessDevelopment of high-efficiency micropixel avalanche photodiodes with fast recovery time and enhanced photon detection efficiency
Background Silicon photo-multipliers (SiPMs) suffer from several important limitations, including long recovery time, dead-space losses caused by surface quenching resistors, limited photon detection efficiency (PDE), and saturation effects under high particle flux conditions. These drawbacks significantly restrict detector performance in high-rate timing applications, radiation monitoring systems, and modern scintillation detectors. Methods Novel MAPD structures employing artificial potential micro-wells and intrinsic micro-channel recovery mechanisms were developed using silicon epitaxial technology. Electrical and optical properties of the devices were experimentally investigated through capacitance-voltage measurements, PDE analysis, and recovery-time characterization. Optimized thin-film bilayers of silicon nitride (Si 3N 4) and silicon dioxide (SiO 2) were further implemented as anti-reflection coatings to maximize quantum efficiency (QE). Results The proposed MAPD structure demonstrated substantial improvements compared to conventional structures. The developed devices achieved nearly 100% photosensitive surface coverage, pixel densities up to 2.8 × 10 4 pixels/mm 2, and PDE approaching 40%. Experimental investigations showed that the recovery time was reduced from approximately 300 μs to 40 ns, corresponding to an improvement factor of approximately 7.5 × 10 3. Conclusions The obtained results demonstrate that optimized electric-field engineering combined with intrinsic micro-channel recovery mechanisms significantly improves both PDE and detector recovery dynamics. The proposed structures represent promising candidates for next-generation high-rate silicon photo-detectors intended for fast timing systems, TOF-PET, scintillation detectors, and high-energy physics experiments.
- Open Access
- 30 March 2026
- Published by Institute of Nuclear Physics of the Agency of the Republic of Kazakhstan for Atomic Energy in Advances in Nuclear Science and Applications
- Vol. 2 (1) , 41-53
The MAVR high-resolution magnetic analyzer setup
This paper presents the MAVR high-resolution magnetic analyzer, operating at the U400 cyclotron and the DRIBs radioactive ion beam facility at the Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research. The analyzer is designed to study nuclear reactions using stable and radioactive ion beams over a wide energy range, from subthreshold energies to 30 MeV per nucleon. Its key features include a large solid angle of 15 msr, high momentum resolution of approximately $10^{-4}$, a focal plane length of 1.9 m, and high charge resolution of approximately $1/60$. The detector system includes a position-sensitive ionization chamber, time-of-flight detectors, and silicon strip detectors, providing reliable identification of reaction products by their mass number $A$ and atomic number $Z$. The optical properties of the analyzer were studied using the MAVRPC code and confirmed experimentally. The possibility of operating in gas-filled mode for heavy ion studies is also discussed.- 30 March 2026
- Published by Institute of Nuclear Physics of the Agency of the Republic of Kazakhstan for Atomic Energy in Advances in Nuclear Science and Applications
- Vol. 2 (1) , 41-53
Open AccessThe MAVR high-resolution magnetic analyzer setup
This paper presents the MAVR high-resolution magnetic analyzer, operating at the U400 cyclotron and the DRIBs radioactive ion beam facility at the Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research. The analyzer is designed to study nuclear reactions using stable and radioactive ion beams over a wide energy range, from subthreshold energies to 30 MeV per nucleon. Its key features include a large solid angle of 15 msr, high momentum resolution of approximately $10^{-4}$, a focal plane length of 1.9 m, and high charge resolution of approximately $1/60$. The detector system includes a position-sensitive ionization chamber, time-of-flight detectors, and silicon strip detectors, providing reliable identification of reaction products by their mass number $A$ and atomic number $Z$. The optical properties of the analyzer were studied using the MAVRPC code and confirmed experimentally. The possibility of operating in gas-filled mode for heavy ion studies is also discussed. - 1 March 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (03) , P03042
Development of a two-channel digital acquisition system for Δ E-E particle identification
We present the design and implementation of a compact digital data acquisition system based on the STM32F407 microcontroller for use in charged-particle spectroscopy. The system digitizes signals from a two-detector telescope (Δ E-E ) and transfers the results to a PC in real time via USB. The approach combines an analog front-end (preamplifier, CR-RC shaper, comparator, and peak detector) with microcontroller-based digitization and data transfer. This setup allows construction of two-dimensional coincidence matrices (Δ E vs. E ) for particle identification.
- 1 March 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (03) , P03042
Development of a two-channel digital acquisition system for Δ E-E particle identification
We present the design and implementation of a compact digital data acquisition system based on the STM32F407 microcontroller for use in charged-particle spectroscopy. The system digitizes signals from a two-detector telescope (Δ E-E ) and transfers the results to a PC in real time via USB. The approach combines an analog front-end (preamplifier, CR-RC shaper, comparator, and peak detector) with microcontroller-based digitization and data transfer. This setup allows construction of two-dimensional coincidence matrices (Δ E vs. E ) for particle identification.
- Open Access
- 30 December 2025
- Published by Institute of Nuclear Physics of the Agency of the Republic of Kazakhstan for Atomic Energy in Advances in Nuclear Science and Applications
- Vol. 1 (4) , 269-284
Empirical formulas for fragmentation production cross section
Production cross sections of neutron-rich nuclei in projectile fragmentation reactions measured at zero degrees are systematically analyzed using published experimental data. By comparing the yields of O, F, Ne, Na, Mg, Al, Si, and P isotopes produced in $^{40}$Ar-induced fragmentation at beam energies of 35~MeV/nucleon, 57--120~MeV/nucleon, and 1~GeV/nucleon, we demonstrate that the production cross sections of neutron-rich fragments are, within experimental uncertainties, essentially independent of the projectile energy over this broad range. Motivated by this limiting-fragmentation behavior, we propose an empirical systematics for neutron-rich fragment production based on the binding energy per nucleon ($\mathrm{BE}/A$) of the final nuclei. The cross sections are found to follow a steep exponential dependence on $\mathrm{BE}/A$, spanning 8--9 orders of magnitude for small variations of $\mathrm{BE}/A$. The systematics is tested for reactions induced by $^{40}$Ar, $^{48}$Ca, $^{58,64,68}$Ni, $^{72}$Zn, $^{76}$Ge, $^{82}$Se, and $^{86}$Kr projectiles on Be and Ta targets, and the corresponding fit parameters are shown to correlate with the fragment charge $Z$ and the projectile neutron-to-proton ratio $(N/Z)_{\mathrm{projectile}}$. Additionally, a complementary analysis based on $Q_{gg}$ systematics (mass difference between projectile and detected fragments) is also presented, and the advantages and limitations of the $\mathrm{BE}/A$-based description for extrapolating yields toward the neutron drip line are discussed.- 30 December 2025
- Published by Institute of Nuclear Physics of the Agency of the Republic of Kazakhstan for Atomic Energy in Advances in Nuclear Science and Applications
- Vol. 1 (4) , 269-284
Open AccessEmpirical formulas for fragmentation production cross section
Production cross sections of neutron-rich nuclei in projectile fragmentation reactions measured at zero degrees are systematically analyzed using published experimental data. By comparing the yields of O, F, Ne, Na, Mg, Al, Si, and P isotopes produced in $^{40}$Ar-induced fragmentation at beam energies of 35~MeV/nucleon, 57--120~MeV/nucleon, and 1~GeV/nucleon, we demonstrate that the production cross sections of neutron-rich fragments are, within experimental uncertainties, essentially independent of the projectile energy over this broad range. Motivated by this limiting-fragmentation behavior, we propose an empirical systematics for neutron-rich fragment production based on the binding energy per nucleon ($\mathrm{BE}/A$) of the final nuclei. The cross sections are found to follow a steep exponential dependence on $\mathrm{BE}/A$, spanning 8--9 orders of magnitude for small variations of $\mathrm{BE}/A$. The systematics is tested for reactions induced by $^{40}$Ar, $^{48}$Ca, $^{58,64,68}$Ni, $^{72}$Zn, $^{76}$Ge, $^{82}$Se, and $^{86}$Kr projectiles on Be and Ta targets, and the corresponding fit parameters are shown to correlate with the fragment charge $Z$ and the projectile neutron-to-proton ratio $(N/Z)_{\mathrm{projectile}}$. Additionally, a complementary analysis based on $Q_{gg}$ systematics (mass difference between projectile and detected fragments) is also presented, and the advantages and limitations of the $\mathrm{BE}/A$-based description for extrapolating yields toward the neutron drip line are discussed. - Open Access
- 30 June 2025
- Published by Institute of Nuclear Physics of the Agency of the Republic of Kazakhstan for Atomic Energy in Advances in Nuclear Science and Applications
- Vol. 1 (2) , 91-104
Structure and reactions of the two-neutron halo nucleus ${}^{11}\text{Li}$The two-neutron halo nucleus ${}^{11}\text{Li}$ represents one of the most striking manifestations of exotic nuclear structure far from stability. Its extremely low two-neutron separation energy, extended matter distribution, and Borromean three-body configuration (${n} + n + {}^{9}\text{Li}$) make it a benchmark system for studying weak binding, neutron correlations, and continuum effects. This review summarizes the experimental approaches that have elucidated the halo structure of ${}^{11}\text{Li}$, including interaction cross section measurements, elastic proton scattering, transfer reactions, momentum distribution analyses, Coulomb breakup. Particular emphasis is placed on the role of the unbound subsystem ${}^{10}\text{Li}$ in shaping the structure of ${}^{11}\text{Li}$ through its virtual $s$-states and low-lying resonances. The experimental findings are interpreted in the context of modern three-body theoretical models, highlighting the interplay between valence neutron correlations and nuclear dynamics at the edge of stability.- 30 June 2025
- Published by Institute of Nuclear Physics of the Agency of the Republic of Kazakhstan for Atomic Energy in Advances in Nuclear Science and Applications
- Vol. 1 (2) , 91-104
Open AccessStructure and reactions of the two-neutron halo nucleus ${}^{11}\text{Li}$The two-neutron halo nucleus ${}^{11}\text{Li}$ represents one of the most striking manifestations of exotic nuclear structure far from stability. Its extremely low two-neutron separation energy, extended matter distribution, and Borromean three-body configuration (${n} + n + {}^{9}\text{Li}$) make it a benchmark system for studying weak binding, neutron correlations, and continuum effects. This review summarizes the experimental approaches that have elucidated the halo structure of ${}^{11}\text{Li}$, including interaction cross section measurements, elastic proton scattering, transfer reactions, momentum distribution analyses, Coulomb breakup. Particular emphasis is placed on the role of the unbound subsystem ${}^{10}\text{Li}$ in shaping the structure of ${}^{11}\text{Li}$ through its virtual $s$-states and low-lying resonances. The experimental findings are interpreted in the context of modern three-body theoretical models, highlighting the interplay between valence neutron correlations and nuclear dynamics at the edge of stability.