Yang Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yang Hu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Matthew Leonard Becker
Duke University
2 shared publications Nicola G. Judge
Department of Chemistry, Duke University, Durham, NC 27708, USA
2 shared publicationsYin Mei Chan
Department of Chemistry, Duke University, Durham, NC 27708, USA
2 shared publications- Adam K. Ekenseair
Department of Chemical Engineering, College of Engineering, Northeastern University, Boston, MA 02115, USA
1 shared publication Neill Li
Department of Orthopedic Surgery
1 shared publicationRebecca K. Willits
Department of Chemical Engineering
1 shared publication
Latest Publications
- Open Access
Empirical Structure–Property Relationships of PLLA-b-PEG-b-PLLA Triblock Copolymers with Tunable Thermal, Tensile, and Swelling Behavior
PLLA-b-PEG-b-PLLA triblock copolymers are promising materials because of their highly tunable properties. However, a systematic understanding of composition–property relationships remains limited. In this study, a series of A-B-A triblock copolymers was synthesized with polyethylene glycol (PEG) as soft center (B) domains and poly(L-lactic acid) (PLLA) as hard end (A) domains via ring-opening polymerization. Copolymer composition and molecular weights were characterized by proton nuclear magnetic resonance spectroscopy (1H NMR) and gel permeation chromatography (GPC). The thermal and mechanical properties of the copolymers were evaluated by differential scanning calorimetry (DSC) and tensile testing. We established quantitative structure–property relationships using empirical data, demonstrating that PLLA block length played a key role in modulating tensile properties, with a near-linear relationship, while PEG molecular weight critically influenced mechanical stability. An approximate minimum PLLA block length of 20 repeat units was found as a threshold required to maintain structural integrity during in vitro 24 h swelling. These findings provide insights and practical guidance for the design of triblock copolymers with tunable thermal, mechanical, and swelling properties of PLLA-b-PEG-b-PLLA triblock copolymers.
Open AccessEmpirical Structure–Property Relationships of PLLA-b-PEG-b-PLLA Triblock Copolymers with Tunable Thermal, Tensile, and Swelling Behavior
PLLA-b-PEG-b-PLLA triblock copolymers are promising materials because of their highly tunable properties. However, a systematic understanding of composition–property relationships remains limited. In this study, a series of A-B-A triblock copolymers was synthesized with polyethylene glycol (PEG) as soft center (B) domains and poly(L-lactic acid) (PLLA) as hard end (A) domains via ring-opening polymerization. Copolymer composition and molecular weights were characterized by proton nuclear magnetic resonance spectroscopy (1H NMR) and gel permeation chromatography (GPC). The thermal and mechanical properties of the copolymers were evaluated by differential scanning calorimetry (DSC) and tensile testing. We established quantitative structure–property relationships using empirical data, demonstrating that PLLA block length played a key role in modulating tensile properties, with a near-linear relationship, while PEG molecular weight critically influenced mechanical stability. An approximate minimum PLLA block length of 20 repeat units was found as a threshold required to maintain structural integrity during in vitro 24 h swelling. These findings provide insights and practical guidance for the design of triblock copolymers with tunable thermal, mechanical, and swelling properties of PLLA-b-PEG-b-PLLA triblock copolymers.
- Open Access
- 27 February 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 214, 303-316
Peptide concentration gradients and aligned microfiber topography synergize to speed and direct Schwann cell migration
- 27 February 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 214, 303-316
Open AccessPeptide concentration gradients and aligned microfiber topography synergize to speed and direct Schwann cell migration
- 25 June 2025
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 26 (7) , 3974-3997
Review of Gaps in the Clinical Indications and Use of Neural Conduits and Artificial Grafts for Nerve Repair and Reconstruction
Peripheral nerve injuries remain a significant clinical challenge, with limited tools available to physicians and patients. Although autografts are the gold standard for nerve reconstruction, they are limited by donor-site morbidity and availability. Commercially available nerve guidance conduits offer alternatives, yet their clinical application remains largely restricted to short nerve gaps with limited success beyond 1 cm. This review provides a summary of the clinical studies on nerve injury repair using commercial nerve guidance conduits and discusses the shortcomings of such devices, including suboptimal mechanical properties, lack of internal guidance structures and bioactivity, and insufficient clinical data. To address these challenges, emerging innovations, such as biofunctionalized materials, conductive scaffolds, and topographically engineered architectures, are readily being explored to improve regenerative outcomes following neural injury. Overall, this work highlights the gaps in commercial devices utilized clinically and brings attention to the evolving landscape of biomaterials research that can transform clinical nerve repair.
- 25 June 2025
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 26 (7) , 3974-3997
Review of Gaps in the Clinical Indications and Use of Neural Conduits and Artificial Grafts for Nerve Repair and Reconstruction
Peripheral nerve injuries remain a significant clinical challenge, with limited tools available to physicians and patients. Although autografts are the gold standard for nerve reconstruction, they are limited by donor-site morbidity and availability. Commercially available nerve guidance conduits offer alternatives, yet their clinical application remains largely restricted to short nerve gaps with limited success beyond 1 cm. This review provides a summary of the clinical studies on nerve injury repair using commercial nerve guidance conduits and discusses the shortcomings of such devices, including suboptimal mechanical properties, lack of internal guidance structures and bioactivity, and insufficient clinical data. To address these challenges, emerging innovations, such as biofunctionalized materials, conductive scaffolds, and topographically engineered architectures, are readily being explored to improve regenerative outcomes following neural injury. Overall, this work highlights the gaps in commercial devices utilized clinically and brings attention to the evolving landscape of biomaterials research that can transform clinical nerve repair.